![Samsung DMT300 Series Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/samsung/dmt300-series/dmt300-series_training-manual_4136760039.webp)
Error Type
Error Mode
Checking Method
Corrective actions
Low Level
Water Error
„Normal‟ +
„Heavy‟ +
„Quick‟ LED
1. Check the connections for the Low Level Sensor
connectors.
- Reconnect the Low Level Sensor connector.
- Faulty: Replace the Low Level Sensor, Remove foreign
material from the floater
- Normal: Replace the Main PBA assy.
- Faulty: Replace the Low Level Sensor, Remove foreign material from the
floater
- Normal: Replace the Main PBA assy.
Button Error
„Normal‟ +
„Delicate‟ LED
Check whether there is condensation on the Main PBA
connector (CN803)
➢
Normal: No condensation
- Faulty: Remove any condensation and moisture.
- Normal: Replace the Control Panel assy.
Trouble Shooting