4. Troubleshooting
4-15
Error type
Error mode
Checking Method
Corrective actions
Detergent is not
dispensed.
None
1. Check whether detergent is inserted into the
dispenser.
- Check whether there is detergent in the Dispenser.
2. Check the connections for the Dispenser connector.
- Reconnect the Dispenser connector.
3. Check the resistance of the Dispenser.
(Remove the connector before measuring.)
Normal: Approx. 2.3 kΩ
➢
- Faulty: Replace the Dispenser.
4. Check the operation of the Dispenser Relay:
Check the operating voltage between the white
wire of the CN1 connector and the white wire of the
CN14 connector.
Normal: 120V (while operating)
➢
New PBA
4-1.Check the operation of the Dispenser Relay:
Check the operating voltage between the white wire
of the CN101 connector and the white wire of the
CN201 connector.
Normal: 120V (while operating)
➢
- Faulty: Replace the Main PBA assy.
New PBA
Содержание DMR78AHS/XAC
Страница 14: ...2 6 2 Features and Specifications Memo ...
Страница 38: ...3 24 3 Disassembly and Reassembly Memo ...
Страница 59: ...4 Troubleshooting 4 21 Memo ...
Страница 61: ...5 2 5 Exploded Views and Parts List 5 1 MAIN DMR77 DMR78 F219 Z019 P143 DMR77 Z019 P143 DMR78 D049 0 1 1 0 ...
Страница 73: ...5 14 5 Exploded Views and Parts List 5 7 MAIN DMR57 0 1 D049 Z019 P143 ...
Страница 85: ...5 26 5 Exploded Views and Parts List ...
Страница 95: ...6 10 6 PCB Diagram Memo ...
Страница 100: ...8 2 8 Schematic D iagram 8 3 TOUCH KEY 7KEY DMR77 DMR78 This Document can not be used without Samsung s authorization ...
Страница 101: ...8 3 8 Schematic Diagram 8 4 TOUCH KEY 3KEY DMR77 DMR78 This Document can not be used without Samsung s authorization ...
Страница 102: ...8 4 8 Schematic D iagram 8 5 TOUCH KEY 7KEY DMR57 This Document can not be used without Samsung s authorization ...
Страница 103: ...8 5 8 Schematic Diagram Memo ...
Страница 104: ...9 1 9 Reference 9 Reference 9 1 Model Number Naming Rules 8 2008 A ALL ...