Wiring Diagram  before 5-1-2009 DMR57 

 

3

Содержание DMR57LFB/XAA

Страница 1: ...Auto 0 45 5 30 17 30 17 30 17 30 11 30 46 30 7 30 7 30 12 30 46 30 20 58 181 No Sanitize Sanitize Normal 120 F 49 C 140 F 60 C 162 F 72 C Heavy 149 F 65 C 158 F 70 C 162 F 72 C Delicate 113 F 45 C 140 F 60 C 162 F 72 C Rinse Quick 113 F 45 C 140 F 60 C 162 F 72 C Smart Auto 113 149 F 45 65 C 140 158 F 60 70 C 162 F 72 C Pre wash 1 2 3 Rinse 1 2 Program Main wash Rinse 3 Dishwasher Cycle Chart Cond...

Страница 2: ...Wiring Diagram after 5 1 2009 DMR57 77 78 2 ...

Страница 3: ...Wiring Diagram before 5 1 2009 DMR57 3 ...

Страница 4: ...Wiring Diagram before 5 1 2009 DMR77 78 4 ...

Страница 5: ...CN801 Key Driver 11 12 5vdc CN502 Disp LED Driver DMR77 78 only CN501 Disp LED Driver CN11 Disp DriverDMR77 CN13 Display LED Driver CN1 PBA Power 1 120vac 3 120vac CN7 1 Power Relay Driver 2 Heater Relay Driver 3 Half Load Sensor DMR77 only 4 Trubidity Sensor 5 Trubidity Transmitter 7 6 5vdc 8 Rinse Aid Sensor 9 6 12vdc CN8 1 Low Water Sensor 3 Overflow Sensor 5 Water Counter 6 Leakage Sensor 8 Th...

Страница 6: ...side of cavity during Installation verify proper loop Check for proper fill valve and flow meter in t1 test mode Water lost in distribution such as inside cups glasses bowls that flip over can cause a drop in water supplying the wash motor and can cause cavitation sound during any cycle Detergent Door Not Opening 1 Never overfill the dispenser compartment with powder or liquid only go below or up ...

Страница 7: ... 31 996 104 26 065 113 21 385 122 17 599 Components Leaking and Poor Washability Check for split wash arms Dishwasher Parts Change 5 2009 Drying Concerns Condensing Dry System is used to conserve energy 1 Verify proper operation of Rinse Aid Dispensing 2 Verify Fan operation 3 Must use a Rinse Agent 4 Should use Sanitize Cycle 5 Should open door between 30 minutes and 3 hours after completion of t...

Страница 8: ...conds during water supply Foreign particles in water supply valve Case Sensor part leakage FlowMeter defect Main PBA defect Leak age Error LE When leakage sensor detects 4 5V or below for 1 seconds Base part hose connection defect SumpandTubassembly defect Drain Pumpassembly defect Main PBA defect Heater Error HE HE1 When the temperature change is 4Ԩ or less within the first 10 minutes after the h...

Страница 9: ...nd circulation pump 2 If a low water level is sensed water is supplied again and the operation continues 3 The current temperature is shown on the display 4 It operates up to 70ºC After temp increases 2 degrees C time is about 50 seconds for each degree C increase t4 Fan Motor Fan Motor not working Press the Delay Start key to start or stop the fan motor Listen for fan run ning t5 Drain Pump Low L...