Component
Voltage
Ω
Water Valve
120vac
1.2 K
Ω
Drain Pump
120vac
42.2
Ω
Heater
120vac
13
Ω
Half Load Mtr
120vac
2.6K
Ω
Fan Mtr
120vac
150
Ω
Disp Wax Mtr
120vac
2.3K
Ω
Circulation Mtr
120vac
16.5
Ω
Thermistor
Temp.
(ºF)
Resistance
(k
Ω
)
41
125.78
50
98.323
59
77.454
68
61.465
77
49.12
86
39.517
95
31.996
104
26.065
113
21.385
122
17.599
Components
Leaking and Poor
Washability
—Check
for split wash arms
Dishwasher Parts Change 5/2009
Drying Concerns
Condensing Dry System is used to
conserve energy
1. Verify proper operation of Rinse Aid
Dispensing.
2. Verify Fan operation.
3. Must use a Rinse Agent
4. Should use Sanitize Cycle
5. Should open door between 30
minutes and 3 hours after completion of
the cycle.
All in One products do not dry as well.
Plastic items will not dry properly.
7
Содержание DMR57LFB/XAA
Страница 2: ...Wiring Diagram after 5 1 2009 DMR57 77 78 2 ...
Страница 3: ...Wiring Diagram before 5 1 2009 DMR57 3 ...
Страница 4: ...Wiring Diagram before 5 1 2009 DMR77 78 4 ...