SAMSUNG
Dryer Owner’s Instructions
A-9
3-WIRE SYSTEM CONNECTIONS
1.
Loosen or remove center terminal block screw.
2.
Connect neutral wire (white or center wire) of the power cord to the center, silver-colored
terminal screw of the terminal block. Tighten screw.
3.
Connect the other wires to outer terminal block screws. Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into your dryer’s rear panel slot.
Secure cover with hold-down screw.
1. External ground connector
2. Neutral grounding wire (green/yellow)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. 3/4” (1.9 cm) UL-listed strain relief
WARNING:
If converting from a 4-wire electrical system to a 3-wire, the ground strap must be reconnected
to the terminal block support to ground the dryer frame to the neutral conductor.
4-WIRE SYSTEM CONNECTIONS
1.
Remove center terminal block screw.
2.
Connect ground wire (green or unwrapped) of power cord to external ground conductor screw.
3.
Connect neutral wire (white or center wire) of power cord and appliance ground wire (green
with yellow stripes) under central screw of the terminal block.
4.
Connect the other wires to outer terminal block screws. Tighten screws.
5.
Tighten strain relief screws.
6.
Insert tab of terminal block cover into your dryer’s rear panel slot.
Secure cover with hold-down screw.
1. External ground connector
2. Green or bare copper wire of power cord
3. 3/4 in. (1.9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5. Grounding wire (green/yellow)
6. Neutral wire (white or center wire)
6.
With a level, check your dryer and make necessary adjustments to the leveling legs.
7.
At this time, make sure all gas connections (on gas models), exhaust and electrical connections are
complete. Plug in your dryer, and check operation by using the checklist below.
8.
(GAS MODELS ONLY)
The burner may not ignite initially due to air in the gas line. Allowing your dryer to operate on a heat setting
will purge the line. If the gas does not ignite within 5 minutes, turn your dryer off and wait 5 minutes. Be sure
the gas supply to your dryer has been turned on. In order to confirm gas ignition, check the exhaust for heat.
FINAL INSTALLATION CHECKLIST
□
Dryer is plugged into electrical outlet and properly grounded.
□
Exhaust ductwork is hooked up and joints taped.
□
Plastic flexible duct is NOT used.
□
Use rigid or stiff-walled flexible metal vent material.
□
Dryer is level with all legs firmly on the floor.
□
Gas models – gas is turned on with no gas leaks.
□
Start your dryer to confirm that it runs, heats, and shuts off.
Installation Instructions