background image

Wind-Free 4Way Cassette

 Features & Benefits

Stage a beautiful yet comfortable environment

With its newly improved design, Wind-Free 4Way Cassette 

supports a clean, aesthetically appealing atmosphere and 

adds a sense of sophistication to work and living spaces. 

Not only is this unit attractively designed, but it also 

uses advanced technologies to optimize comfort in any 

environment.

The Samsung Wind-Free 4Way Cassette indoor air 

conditioning system delivers polish, comfort and 

efficiency with features such as:

 

Stylishly clean design.

 Add panache to interior spaces

with a choice of clean, streamlined panel patterns in a

lightweight build.

 

Robust operation.

 Control the atmosphere perfectly

with an advanced design for superior airflow and

cooling/heating performance.

 

Low maintenance and simple installation.

 Ease

installation and minimize maintenance with a

detachable, no-drip design.

Wind-Free 4Way Cassette - 

Stylishly clean design

Aesthetic panel and display

Wind-Free 4Way Cassette offers two different pattern 

designs for the panel. The simple display design with 

rounded corners adds a chic sophistication to the interior.

Power Defrost Time

Clean

Neat and clean design

The indoor Wind-Free 4Way Cassette boasts a smart 

design that promotes a neat and clean look. The 

completely hermetic blade structure keeps the indoor 

unit clean by preventing dust or other foreign substances 

from entering it. The internal parts of the indoor unit are 

also out of sight when the blade is shut, thus improving 

the unit’s appearance.

Lightweight build

The Samsung Wind-Free 4Way Cassette indoor unit is 

now lighter in weight at 17 kg. It is one of the lightest 

indoor units in the industry, about 40 percent lighter than 

conventional products.

40%

29kg

17kg

40%

29kg

17kg

Wind-Free 4Way Cassette

Conventional

*Based on 10kW

Содержание CNH HDB Series

Страница 1: ...SINGLE Technical Data Book Low Ambient Line up forAmerica R410A Cooling Only Model CNH 4DB AC BN4DCH AA CNH HDB AC BNHDCH AA CNH ADB AC BNADCH AA CNH TDB AC BNTDCH AA CXC SCB AC BXSCCC AA ...

Страница 2: ... 0 Released 2021 CAC TDB for North America Low Ambient Line up 22 02 07 Ver 1 1 Modified the Net Weight Spec of the Wind Free 4Way Cassette 22 09 05 Ver 1 2 Updated the Specification page 22 12 12 Ver 1 3 Updated the some data in specification and sound page ...

Страница 3: ...mption compared to non inverter air conditioners 200 300 400 500 600 Wh h Saving 302 Wh h 621 4 Wh h Non inverter Wind Free Cooling with Micro holes The Wind Free Air conditioner pushes air out through 15 000 micro holes in the panel producing a dispersed and gentle flow of air actually defined as still air and the key here is all of those holes create a still cooled air flow that infiltrates the ...

Страница 4: ...to 50 and provide warmth in the freezing cold of 20 to ensure a constant and comfortable home environment Ideal comfort in minutes The CAC Single digital inverter air conditionerworks at maximum capacity at startup As soon as the temperature reaches the desired or set temperature CAC Single performs fine adjustments to cope with any changes This means less temperature fluctuation and ideal comfort...

Страница 5: ... Way Cassette 600x600 4 4 Way Cassette 360 Cassette Wind Free 4 Way Cassette L LSP Duct H HSP Duct C Ceiling J Console A AR9500 Wall Mounted 5 2 Feature1 Outdoor Unit A Inv Side General Temp S Inv Side Low Temp Q Inv Side Tropical Temp F Inv Top Tropical Temp 6 Feature 7 Version B 2022 Model Name C 1 N 2 H 3 36 4 4 5 D 6 B 7 C Cooling Only H Heat Pump T MAX4 Wall Mounted Z Multi position AHU F Fla...

Страница 6: ... Unit 5 Product Notation 6 Feature F Flagship S Standard D Deluxe P Premium 7 Rating Voltage C 1Φ 208 230V 60Hz 8 Mode B 2022 C Cooling Only H Heat Pump 1 1 Way Cassette N 4 Way Cassette 600x600 Wind Free 4 Way Cassette 600x600 4 4 Way Cassette 360 Cassette Wind Free 4 Way Cassette L LSP Duct H HSP Duct C Ceiling J Console A AR9500 Wall Mounted T MAX4 Wall Mounted Z Multi position AHU ...

Страница 7: ...N Indoor Unit NASA X Outdoor Unit NASA 5 Feature1 A Inv Side General Temp S Inv Side Low Temp Q Inv Side Tropical Temp F Inv Top Tropical Temp 6 Feature2 7 Rating Voltage C 1Φ 208 230V 60Hz H 3Φ 400V 60Hz 8 Mode H Heat Pump R410A C Cooling Only R410A E Heat Pump R22 D Cooling Only R22 AC CAC B 2022 F Flagship S Standard D Deluxe P Premium C Deluxe Low Temp ...

Страница 8: ... Line up Indoorunit Model Capacity kBtu h 18 24 30 36 Wind Free 4Way Cassette OutdoorUnit Model Capacity kBtu h 18 24 30 36 1Phase Duct S Wall Mounted Type ...

Страница 9: ... Contents Wind Free 4Way Cassette 10 Outdoor Units 68 Installation 85 26 Duct S Wall Mounted Type 49 ...

Страница 10: ...e 4Way Cassette 1 Specification 12 2 Summary Table 16 3 Capacity Table 17 4 Dimensional Drawing 19 5 Center of Gravity 21 6 Electrical Wiring Diagram 22 7 Sound Data 23 8 Temperature and air flow distribution 25 ...

Страница 11: ...ation Ease installation and minimize maintenance with a detachable no drip design Wind Free 4Way Cassette Stylishly clean design Aesthetic panel and display Wind Free 4Way Cassette offers two different pattern designs for the panel The simple display design with rounded corners adds a chic sophistication to the interior Power Defrost Time Clean Neat and clean design The indoorWind Free 4Way Casset...

Страница 12: ...0 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Green Hydrophile Green Hydrophile Turbo Turbo EA 1 1 m3 min 24 0 21 0 18 0 24 0 21 0 18 0 ft min 848 742 636 848 742 636 l s 400 350 300 400 350 300 External Static Pressure Min Std Max In Wg BLDC BLDC W x n 65 x 1 65 x 1 Drain Φ mm OD26 67 OD26 67 Sound Pressure Level H M L dB A 36 33 30 36 33 30 Sound Power Level dB A 53 53 kg lbs 15 9 35 1 16 0 35 3 kg l...

Страница 13: ...MWR SH11UN Included Included in gal h 29 5 16 6 34gal h 29 5 16 6 34gal h Additional Accessories Removable Washable Removable Washable Φ V Hz 1 2 208 230 60 1 2 208 230 60 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Anti Corrosion Anti Corrosion UG9TK3150FE4SG UG4T200FUAE4SG Twin BLDC Twin BLDC kW 1 42 1 79 Type POE POE Initial Charge cc fl oz 500 650 Propeller Propeller Front Front EA 1 1 m 3 min 40 5...

Страница 14: ...ube Fin Tube Fin Al Al Tube Cu Cu Green Hydrophile Green Hydrophile Turbo 3D Turbo 3D EA 1 1 m3 min 28 2 23 6 17 8 34 2 25 8 19 0 ft min 996 833 629 1208 911 671 l s 470 393 297 570 430 317 External Static Pressure Min Std Max In Wg BLDC BLDC W x n 97 x 1 97 x 1 Drain Φ mm OD26 67 OD26 67 Sound Pressure Level H M L dB A 37 34 30 43 38 33 Sound Power Level dB A 53 59 kg lbs 19 0 41 9 21 2 46 7 kg l...

Страница 15: ... SH11UN Included Included in gal h 29 5 16 6 34gal h 29 5 16 6 34gal h Additional Accessories Removable Washable Removable Washable Φ V Hz 1 2 208 230 60 1 2 208 230 60 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Anti Corrosion Anti Corrosion UG8T300FUBJUSG UG8T300FUBJUSG Twin BLDC Twin BLDC kW 2 82 2 82 Type POE POE Initial Charge cc fl oz 1200 1200 Propeller Propeller Front Front EA 1 1 m 3 min 78 78...

Страница 16: ...ased on cooling operation Electric Characteristics Model Outdoor Unit Input Current Amperes Power Supply Indoor Unit Outdoor Unit Rated Voltage range Outdoor Unit Indoor Unit Total MCA A MOP A Hz Volts Min Max Cooling Heating CNH184DB AC018BN4DCH AA CXC18SCB AC018BXSCCC AA 60 208 to 230 187 253 13 5 15 CNH244DB AC024BN4DCH AA CXC24SCB AC024BXSCCC AA 60 208 to 230 187 253 20 1 25 CNH304DB AC030BN4D...

Страница 17: ... 17 6 14 2 2 15 18 3 14 7 2 19 18 9 15 1 2 24 19 3 15 0 2 26 20 2 14 8 2 28 21 3 14 5 2 33 122 11 9 11 1 1 61 12 6 11 4 1 65 13 1 11 8 1 68 13 5 12 2 1 71 13 8 12 0 1 73 14 5 11 9 1 75 15 2 11 7 1 78 86 72 90 75 Outdoor Temp DB Indoor Temperature DB WB 68 57 72 61 77 64 80 67 82 70 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH...

Страница 18: ... 6 2 88 24 7 22 3 2 94 25 5 23 0 3 00 26 0 22 7 3 03 27 3 22 5 3 06 28 7 22 0 3 12 122 19 9 18 5 2 70 21 0 19 1 2 75 21 8 19 6 2 81 22 5 20 3 2 87 23 0 20 0 2 90 24 1 19 8 2 92 25 3 19 5 2 98 86 72 90 75 Outdoor Temp DB Indoor Temperature DB WB 68 57 72 61 77 64 80 67 82 70 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW ...

Страница 19: ...NH184DB AC018BN4DCH AA CNH244DB AC024BN4DCH AA 1 Liquid pipe connection Φ 6 35mm 1 4 2 Gas pipe connection Φ 12 7mm 1 2 Φ 15 88mm 5 8 3 Drain pipe connection VP25 OD32mm 1 26 ID25mm 0 98 4 Power supply Communication wiring conduit 5 Fresh air intake knockout hole Φ101mm 4 Use M4 Screw NOTE As for suspension bolt please use M8 M10 Procured at local site ...

Страница 20: ...uid pipe connection Φ 9 52mm 3 8 2 Gas pipe connection Φ 15 88mm 5 8 3 Drain pipe connection VP25 OD32mm 1 26 ID25mm 0 98 4 Power supply Communication wiring conduit 5 Fresh air intake knockout hole Φ101mm 4 Use M4 Screw NOTE As for suspension bolt please use M8 M10 Procured at local site Wind Free 4Way Cassette ...

Страница 21: ...e 4Way Cassette 5 Centerof Gravity 5 Centerof Gravity Units mm inches 890 910 35 1 16 35 13 16 890 910 35 1 16 35 13 16 445 17 1 2 445 17 1 2 A B A B 24kBtu h 30 36kBtu h 305 12 130 5 1 8 265 10 7 16 114 4 1 2 ...

Страница 22: ...VA IN 10K EXT_CONTROL EXTERNAL_CONTROL EVA OUT 10K Thermistor EVA OUT 10K NOTE This wiring diagram applies only to the Indoor unit Symbols show as follow blk black red red blu blue wht white yel yellow brn brown sky skyblue grn green For connection wiring indoor outdoor transmission F1 F2 indoor wired remote controller transmission F3 F4 Protective earth screw connector The wire quantity Wind Free...

Страница 23: ...without prior notice Sound pressure level is obtained in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment Sound pressure level may differ depending on operation condition dBA A weighted sound pressure level Reference acoustic pressure 0 dB 20μPa Model High Mid CNH184DB AC018BN4DCH AA 36 33 CNH244DB AC024BN4DCH AA 36 33 CNH304DB AC030BN4DC...

Страница 24: ... that a sound source generates dBA A weighted sound power level Reference power 1pW Measured according to ISO 3741 Unit dB A Model Cooling CNH184DB AC018BN4DCH AA 53 CNH244DB AC024BN4DCH AA CNH304DB AC030BN4DCH AA 2 CNH244DB AC024BN4DCH AA NC Curve 1 CNH184DB AC018BN4DCH AA 3 CNH304DB AC030BN4DCH AA 4 CNH364DB AC036BN4DCH AA CNH364DB AC036BN4DCH AA 53 53 59 ...

Страница 25: ...45 degree CNH244DB AC024BN4DCH AA Cooling AirVelocity distribution Cooling temperature distribution Discharge angle 45 degree Discharge angle 45 degree CNH304DB AC030BN4DCH AA Cooling AirVelocity distribution Discharge angle 45 degree Cooling temperature distribution Discharge angle 45 degree CNH364DB AC036BN4DCH AA Cooling AirVelocity distribution Discharge angle 45 degree Cooling temperature dis...

Страница 26: ...Duct S 1 Specification 28 2 Summary Table 32 3 Capacity Table 33 4 Dimensional Drawing 35 5 Center of Gravity 37 6 Electrical Wiring Diagram 38 7 Sound Data 39 8 Temperature and air flow distribution 41 ...

Страница 27: ... multiple access points for easy setup exactly where needed Smart pressure control Samsung Ducted Type units feature a smart pressure control system This system adjusts the fan speed based on the external static pressure ESP delivering consistent cooling and heating power regardless of the surrounding environment Convenient installation The optional lift up drain pump lifts condensed water up to 2...

Страница 28: ...Al Tube Cu Cu Hydrophile Hydrophile Sirocco Sirocco EA 3 3 m3 min 17 5 15 2 13 5 21 2 19 16 8 ft min 618 537 477 749 671 593 l s 292 253 225 353 317 280 External Static Pressure Min Std Max In Wg 0 10 0 58 0 79 0 10 0 58 0 79 BLDC BLDC W x n 153 153 Drain Φ mm OD26 67 OD26 67 Sound Pressure Level H M L Silent dB A 40 36 32 41 37 33 Sound Power Level dB A 61 62 kg lbs 34 9 76 9 35 0 77 2 kg lbs 39 ...

Страница 29: ... SH11UN MWR WG00UN MWR SH11UN Included Included in gal h 29 53 6 34 29 53 6 34 Additional Accessories Φ V Hz 1 2 208 230 60 1 2 208 230 60 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Green Hydrophile Green Hydrophile UG9TK3150FE4SG UG4T200FUAE4SG BLDC BLDC kW 1 42 1 79 Type POE POE Initial Charge cc fl oz 500 650 Propeller Propeller Front Front EA 1 1 m 3 min 40 51 ft min 1 413 1 801 l s 667 850 BLDC B...

Страница 30: ...Al Tube Cu Cu Hydrophile Hydrophile Sirocco Sirocco EA 3 3 m3 min 26 21 5 17 33 29 24 ft min 918 759 600 1165 1024 848 l s 433 358 283 550 483 400 External Static Pressure Min Std Max In Wg 0 10 0 58 0 79 0 12 0 58 0 79 BLDC BLDC W x n 153 244 Drain Φ mm OD26 67 OD26 67 Sound Pressure Level H M L Silent dB A 41 37 33 43 39 35 Sound Power Level dB A 63 65 kg lbs 35 0 77 2 44 0 97 0 kg lbs 39 5 87 1...

Страница 31: ...1UN MWR WG00UN MWR SH11UN Included Included in gal h 29 53 6 34 29 53 6 34 Additional Accessories Φ V Hz 1 2 208 230 60 1 2 208 230 60 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Green Hydrophile Green Hydrophile UG8T300FUBJUSG UG8T300FUBJUSG BLDC BLDC kW 2 82 2 82 Type POE POE Initial Charge cc fl oz 1200 1200 Propeller Propeller Front Front EA 1 1 m 3 min 78 78 ft min 2 755 2 755 l s 1 300 1 300 BLDC...

Страница 32: ...ased on cooling operation Electric Characteristics Model Outdoor Unit Input Current Amperes Power Supply Indoor Unit Outdoor Unit Rated Voltage range Outdoor Unit Indoor Unit Total MCA A MOP A Hz Volts Min Max Cooling Heating CNH18HDB AC018BNHDCH AA CXC18SCB AC018BXSCCC AA 60 208 to 230 187 253 13 5 15 CNH24HDB AC024BNHDCH AA CXC24SCB AC024BXSCCC AA 60 208 to 230 187 253 20 1 25 CNH30HDB AC030BNHD...

Страница 33: ...4 2 2 45 18 3 14 7 2 50 18 9 15 1 2 55 19 3 15 0 2 58 20 2 14 8 2 60 21 3 14 5 2 65 122 11 9 11 1 1 84 12 6 11 4 1 88 13 1 11 8 1 92 13 5 12 2 1 96 13 8 12 0 1 97 14 5 11 9 1 99 15 2 11 7 2 03 80 67 82 70 86 72 90 75 Outdoor Temp DB Indoor Temperature DB WB 68 57 72 61 77 64 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW...

Страница 34: ...4 7 22 3 3 14 25 5 23 0 3 20 26 0 22 7 3 23 27 3 22 5 3 27 28 7 22 0 3 33 122 19 9 18 5 2 88 21 0 19 1 2 93 21 8 19 6 2 99 22 5 20 3 3 06 23 0 20 0 3 09 24 1 19 8 3 12 25 3 19 5 3 18 Outdoor Temp DB Indoor Temperature DB WB 68 57 72 61 77 64 80 67 82 70 86 72 90 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH k...

Страница 35: ...0BNHDCH AA NO Name Description CNH24HDB AC024BNHDCH AA CNH30HDB AC030BNHDCH AA 1 Liquid pipe connection Φ6 35 mm 1 4 Φ9 52 mm 3 8 2 Gas pipe connection Φ15 88 mm 5 8 3 Drain pipe connection 3 4 OD26 67mm 1 05 4 Power supply connection 5 Air discharge flange 6 Air suction flange 7 Hook M8 M10 CNH18HDB AC018BNHDCH AA Φ12 7 mm 1 2 ...

Страница 36: ... CNH36HDB AC036BNHDCH AA NO Name Description 1 Liquid pipe connection Φ9 52 mm 3 8 2 Gas pipe connection Φ15 88 mm 5 8 3 Drain pipe connection 3 4 OD26 67mm 1 05 4 Power supply connection 5 Air discharge flange 6 Air suction flange 7 Hook M8 M10 ...

Страница 37: ... E F B D C Model A B C D E F CNH18HDB AC018BNHDCH AA CNH24HDB AC024BNHDCH AA CNH30HDB AC030BNHDCH AA 700 27 9 16 265 10 7 16 1250 49 3 16 565 18 5 16 252 9 15 16 125 4 15 16 CNH36HDB AC036BNHDCH AA 700 27 9 16 265 10 7 16 1350 53 1 8 650 25 5 8 301 11 13 16 150 5 15 16 ...

Страница 38: ...wn sky skyblue grn green For connection wiring indoor outdoor transmission F1 F2 indoor wired remote controller transmission F3 F4 Protective earth screw MAIN PBA Printed circuit board MAIN EEV Electronic Expansion Valve ROOM 10K Thermistor ROOM in 10K EXT_CONTROL EXTERNAL CONTROL EVA IN 10K Thermistor EVA IN 10K EVA OUT 10K Thermistor EVA OUT 10K M BLDC BLDC Motor DISCHARGE 10K Thermistor DISCHAR...

Страница 39: ... dB 20μPa Model High Mid CNH18HDB AC018BNHDCH AA 40 36 Low 32 CNH24HDB AC024BNHDCH AA 2m 2m Suction Discharge Duct Duct Microphone 41 37 33 CNH30HDB AC030BNHDCH AA CNH36HDB AC036BNHDCH AA 41 37 33 43 39 35 60 55 60 60 55 60 NC 60 NC 60 55 55 NC 55 NC 55 50 High 45 50 50 High 45 50 NC 50 NC 50 45 45 Mid NC 45 40 35 Low 30 25 20 15 10 40 Mid 35 Low NC 45 40 40 NC 40 NC 40 35 35 NC 35 NC 35 30 30 25 ...

Страница 40: ...DCH AA 3 CNH30HDB AC030BNHDCH AA 4 CNH36HDB AC036BNHDCH AA CNH30HDB AC030BNHDCH AA CNH36HDB AC036BNHDCH AA 63 65 70 70 70 65 65 65 NC 70 60 60 NC 70 60 NC 60 55 55 NC 60 55 NC 55 50 50 NC 55 50 NC 50 45 45 NC 50 45 NC 45 40 40 NC 45 40 NC 40 35 35 NC 40 35 NC 35 30 30 NC 35 30 NC 30 25 25 NC 30 25 NC 25 20 20 NC 25 20 NC 20 15 15 NC 20 15 70 65 60 55 50 45 40 35 30 25 20 15 10 NC 15 10 10 NC 15 10...

Страница 41: ...inWg 0 3 P 0 4 Option Code 01B3FC 1C54DF 2F343C 370020 3 External Static Pressure inWg 0 4 P 0 5 Option Code 01B3FC 1C5933 2F343C 370020 4 External Static Pressure inWg 0 1 P 0 2 Option Code 01B3FC 1C5416 2F343C 370020 1 External Static Pressure inWg 0 2 P 0 3 Option Code 01B3FC 1C547A 2F343C 370020 2 External Static Pressure inWg 0 5 P 0 6 Option Code 01B3FC 1C5997 2F343C 370020 5 1 2 Lowerlimito...

Страница 42: ...l Static Pressure inWg AirFlow Rate CFM 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 400 500 600 700 800 900 1000 1100 External Static Pressure inWg 0 7 P 0 8 Option Code 01B3FC 1C5E50 2F343C 370020 7 7 Lowerlimitof external staticpressure Upperlimitof external staticpressure HIGH MID LOW ...

Страница 43: ... 3 P 0 4 Option Code 01B3FC 1C55E1 27484F 370020 3 External Static Pressure inWg 0 4 P 0 5 Option Code 01B3FC 1C5935 27484F 370020 4 External Static Pressure inWg 0 1 P 0 2 Option Code 01B3FC 1C542A 27484F 370020 1 External Static Pressure inWg 0 2 P 0 3 Option Code 01B3FC 1C548E 27484F 370020 2 External Static Pressure inWg 0 5 P 0 6 Option Code 01B3FC 1C5998 27484F 370020 5 1 2 Lowerlimitof exte...

Страница 44: ...tatic Pressure inWg AirFlow Rate CFM 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 1 0 8 0 9 500 600 700 800 900 1000 1100 1200 External Static Pressure inWg 0 7 P 0 8 Option Code 01B3FC 1C5D5F 27484F 370020 7 7 Lowerlimitof external staticpressure Upperlimitof external staticpressure HIGH MID LOW ...

Страница 45: ...c Pressure inWg 0 3 P 0 4 Option Code 01B3FC 1C5922 275A5E 370020 3 External Static Pressure inWg 0 4 P 0 5 Option Code 01B3FC 1C5967 275A5E 370020 4 External Static Pressure inWg 0 1 P 0 2 Option Code 01B3FC 1C547B 275A5E 370020 1 External Static Pressure inWg 0 2 P 0 3 Option Code 01B3FC 1C54DE 275A5E 370020 2 External Static Pressure inWg 0 5 P 0 6 Option Code 01B3FC 1C59B9 275A5E 370020 5 1 2 ...

Страница 46: ...ic Pressure inWg 500 600 700 800 900 1000 1100 1200 1300 AirFlow Rate CFM 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 External Static Pressure inWg 0 7 P 0 8 Option Code 01B3FC 1C5D3E 275A5E 370020 7 7 Lowerlimitof external staticpressure Upperlimitof external staticpressure HIGH MID LOW ...

Страница 47: ...ternal Static Pressure inWg 7 5 P 10 Option Code 01B3FC 1C54CE 276975 370045 3 External Static Pressure inWg 10 P 12 5 Option Code 01B3FC 1C55F1 276975 370045 4 External Static Pressure inWg 2 5 P 5 Option Code 01B3FC 1C5439 276975 370045 1 External Static Pressure inWg 5 P 7 5 Option Code 01B3FC 1C548C 276975 370045 2 External Static Pressure inWg 12 5 P 15 Option Code 01B3FC 1C5933 276975 370045...

Страница 48: ...c Pressure inWg AirFlow Rate CFM 800 900 1000 1100 1200 1300 1400 1500 1600 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 1 0 8 0 9 External Static Pressure inWg 17 5 P 20 Option Code 01B3FC 1C59A6 276975 370045 7 7 Lowerlimitof external staticpressure Upperlimitof external staticpressure HIGH MID LOW ...

Страница 49: ...ification 52 2 Summary Table 56 3 Capacity Table 57 4 Dimensional Drawing 59 5 Center of Gravity 61 6 Electrical Wiring Diagram 62 7 Sound Data 64 8 Temperature and air flow distribution 66 Wall Mounted Type ...

Страница 50: ...ove the specified threshold Requires additional components MIM B14 foreach unit Wall Mounted Type Wind Free Quiet Operation Wind Free airconditionerwork much more smoothlyand quietly At its lowest level it onlygenerates 21dB A of sound which is almost as quiet as awhisper 21dB Tested on the AC026TNXDKG EU model in quiet mode 7 Segment display A large numeric display with clear and simple icons mak...

Страница 51: ...h the set temperature Instantly cool down your space with Samsung s Turbo Cooling technology Good sleep The quality of sleep you get directly impacts your physical and mental health Concerned with your health Samsung performed extensive experiments to determine the ideal temperatures needed to quickly fall asleep Wall Mounted Type ...

Страница 52: ...l Tube Cu Cu Green Hydrophile Green Hydrophile Cross flow Cross flow EA 1 1 m3 min 17 4 15 3 12 5 17 8 15 2 13 2 ft min 614 540 441 629 537 466 l s 290 255 208 297 253 220 External Static Pressure Min Std Max In Wg BLDC BLDC W x n 27 x 1 27 x 1 Drain Φ mm ID18 ID18 Sound Pressure Level H M L Silent dB A 42 37 32 29 44 39 35 30 Sound Power Level dB A 60 61 kg lbs 11 7 25 8 12 7 28 0 kg lbs 13 5 29 ...

Страница 53: ...DB96 24901P MWR WG00UN MWR SH11UN MWR WG00UN MWR SH11UN in gal h Additional Accessories Washable Washable Φ V Hz 1 2 208 230 60 1 2 208 230 60 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Anti Corrosion Anti Corrosion UG9TK3150FE4SG UG4T200FUAE4SG Twin BLDC Twin BLDC kW 1 42 1 79 Type POE POE Initial Charge cc fl oz 500 650 Propeller Propeller Front Front EA 1 1 m 3 min 40 51 ft min 1 413 1 801 l s 667 ...

Страница 54: ...Al Al Tube Cu Cu Green Hydrophile Green Hydrophile Cross flow Cross flow EA 2 2 m3 min 22 0 20 5 19 23 5 21 3 19 8 ft min 777 724 671 830 752 699 l s 367 342 317 392 355 330 External Static Pressure Min Std Max In Wg BLDC BLDC W x n 58 X 1 58 X 1 Drain Φ mm ID18 ID18 Sound Pressure Level H M L Silent dB A 49 47 45 37 51 48 46 38 Sound Power Level dB A 63 65 kg lbs 18 5 40 8 18 5 40 8 kg lbs 22 0 4...

Страница 55: ...MWR WG00UN MWR SH11UN MWR WG00UN MWR SH11UN in gal h Additional Accessories Washable Washable Φ V Hz 1 2 208 230 60 1 2 208 230 60 Fin Tube Fin Tube Fin Al Al Tube Cu Cu Anti Corrosion Anti Corrosion UG8T300FUBJUSG UG8T300FUBJUSG Twin BLDC Twin BLDC kW 2 82 2 82 Type POE POE Initial Charge cc fl oz 1200 1200 Propeller Propeller Front Front EA 1 1 m 3 min 78 78 ft min 2 755 2 755 l s 1 300 1 300 BL...

Страница 56: ...istics Model Outdoor Unit Input Current Amperes Power Supply Indoor Unit Outdoor Unit Rated Voltage range Outdoor Unit Indoor Unit Total MCA A MOP A Hz Voltz Min Max Cooling Heating CNH18ADB AC018BNADCH AA CXC18SCB AC018BXSCCC AA 60 208 to 230 187 253 13 5 15 CNH24ADB AC024BNADCH AA CXC24SCB AC024BXSCCC AA 60 208 to 230 187 253 20 1 25 CNH30TDB AC030BNTDCH AA CXC30SCB AC030BXSCCC AA 60 208 to 230 ...

Страница 57: ...16 8 13 5 2 16 17 5 14 0 2 21 18 0 14 4 2 25 18 4 14 3 2 27 19 3 14 1 2 30 20 2 13 8 2 34 122 11 1 10 3 1 62 11 7 10 7 1 66 12 2 11 0 1 69 12 6 11 3 1 73 12 9 11 2 1 74 13 5 11 1 1 76 14 2 10 9 1 79 Outdoor Temp DB Indoor Temperature DB WB 68 57 72 61 77 64 80 67 82 70 86 72 90 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH ...

Страница 58: ...3 11 21 8 19 6 3 17 22 5 20 3 3 23 23 0 20 0 3 27 24 1 19 8 3 30 25 3 19 5 3 36 122 18 6 17 2 2 91 19 6 17 8 2 96 20 4 18 3 3 03 21 0 18 9 3 09 21 4 18 7 3 12 22 5 18 5 3 15 23 6 18 2 3 21 Outdoor Temp DB Indoor Temperature DB WB 68 57 72 61 77 64 80 67 82 70 86 72 90 75 TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH MBH kW MBH...

Страница 59: ... 2 7 16 2 9 16 65 0 2 9 16 65 0 631 5 24 7 8 84 0 3 5 16 29 0 1 1 8 64 0 2 1 2 64 0 2 1 2 175 6 6 15 16 29 0 1 1 8 1054 5 41 1 2 215 8 7 16 299 11 3 4 65 0 2 9 16 58 1 2 5 16 62 4 2 7 16 4 Dimensional Drawing Wall Mounted Type CNH18ADB AC018BNADCH AA CNH24ADB AC024BNADCH AA ...

Страница 60: ...hole for left piping 364 67 64 2 9 16 14 5 16 2 65 2 9 16 34 1 3 8 2 5 8 6 1 8 50 3 8 Wall hole for right rear piping Wall hole for left rear piping 412 1280 345 207 111 253 207 16 1 4 9 15 16 4 3 8 8 1 8 13 9 16 8 1 8 19 5 66 2 5 8 72 2 13 16 54 Knockout hole for right piping 335 1010 3 4 54 2 1 8 66 72 2 13 16 2 5 8 2 1 8 39 3 4 13 3 16 ...

Страница 61: ...nches 1280 50 3 8 412 16 1 4 345 13 9 16 207 8 1 8 207 8 1 8 253 9 15 16 111 4 3 8 Units mm inches 1054 5 41 1 2 299 0 11 3 4 215 0 8 1 2 479 3 18 7 8 133 8 5 1 4 100 8 3 15 16 CNH18ADB AC018BNADCH AA CNH24ADB AC024BNADCH AA CNH30TDB AC030BNTDCH AA CNH36TDB AC036BNTDCH AA ...

Страница 62: ...cuit board DISPLAY EVA MID 10K Thermistor EVA OUT ROOM2 10K External Thermistor ROOM Option NOTE This wiring diagram applies only to the Indoor unit Symbols show as follow blk black red red blu blue wht white yel yellow brn brown sky skyblue grn green For connection wiring indoor outdoor transmission F1 F2 indoor wired remote controller transmission F3 F4 Protective earth screw CNH18ADB AC018BNADC...

Страница 63: ...stor EVA IN 10K EVA OUT Thermistor EVA OUT 10K NOTE This wiring diagram applies only to the Indoor unit Symbols show as follow blk black red red blu blue wht white yel yellow brn brown sky skyblue grn green For connection wiring indoor outdoor transmission F1 F2 indoor wired remotecontroller transmission F3 F4 Protective earth screw CNH30TDB AC030BNTDCH AA CNH36TDB AC036BNTDCH AA ...

Страница 64: ...el is obtained in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment Sound pressure level may differ depending on operation condition dBA A weighted sound pressure level Reference acoustic pressure 0 dB 20μPa Model High Mid CNH18ADB AC018BNADCH AA 42 37 CNH24ADB AC024BNADCH AA 44 39 CNH30TDB AC030BNTDCH AA 49 47 Low 32 35 45 CNH36TDB AC036B...

Страница 65: ...at a sound source generates dBA A weighted sound power level Reference power 1pW Measured according to ISO 3741 Unit dB A Model Cooling CNH18ADB AC018BNADCH AA 60 CNH24ADB AC024BNADCH AA CNH30TDB AC030BNTDCH AA 2 CNH24ADB AC024BNADCH AA NC Curve 1 CNH18ADB AC018BNADCH AA 3 CNH30TDB AC030BNTDCH AA 4 CNH36TDB AC036BNTDCH AA CNH36TDB AC036BNTDCH AA 61 63 65 ...

Страница 66: ...018BNADCH AA Cooling AirVelocity distribution Discharge angle 20 degree Cooling temperature distribution Discharge angle 20 degree CNH24ADB AC024BNADCH AA Cooling AirVelocity distribution Discharge angle 20 degree Cooling temperature distribution Discharge angle 20 degree Wall Mounted Type ...

Страница 67: ...g AirVelocity distribution Discharge angle 20 degree Cooling temperature distribution Discharge angle 20 degree CNH36TDB AC036BNTDCH AA Cooling AirVelocity distribution Discharge angle 20 degree Cooling temperature distribution Discharge angle 20 degree Wall Mounted Type ...

Страница 68: ... 1 Summary Table 69 2 Dimensional Drawing 70 3 Center of Gravity 73 4 Electrical Wiring Diagram 75 5 Sound Data 77 6 Capacity Correction 79 7 Operation Range 82 8 Piping Diagram 83 OutdoorUnits ...

Страница 69: ... Net Weight lbs Airflow CFM Sound Pressure Level dBA Sound Power Level dBA Cooling Heating 18 000 CXC18SCB AC018BXSCCC AA 34 65 x 25 12 x 12 20 89 3 1 413 48 62 24 000 CXC24SCB AC024BXSCCC AA 34 65 x 31 42 x 12 20 115 7 1 801 50 30 000 CXC30SCB AC030BXSCCC AA 37 01 x 39 29 x 12 99 156 5 2 755 52 36 000 CXC36SCB AC036BXSCCC AA 37 01 x 39 29 x 12 99 156 5 2 755 54 65 67 69 ...

Страница 70: ...sional Drawing OutdoorUnits CXC18SCB AC018BXSCCC AA Units mm inches No Name Description 1 Refrigerant liquid pipe Φ 12 7mm 1 2 2 Refrigerant gas pipe Φ 6 35mm 1 4 3 Drain hole Connect with provided drain plug ...

Страница 71: ...Units 2 Dimensional D awing CXC24SCB AC024BXSCCC AA Units mm inches No Name Description 1 Refrigerant liquid pipe 2 Refrigerant gas pipe Φ 6 35mm 1 4 3 Drain hole Connect with provided drain plug Φ 15 88mm 5 8 ...

Страница 72: ...nches No Name Description 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Piping intake knockout hole Front Side Rear Bottom 4 Powerwiring conduit 5 Communication wiring conduit 6 Drain Hole Φ 9 52mm 3 8 Φ 15 88mm 5 8 Front Side Rear Φ 34mm 1 3 8 Front Side Rear Φ 22mm 7 8 Connect with provided drain plug 22 7 8 ...

Страница 73: ...3 3 C Cent enter erof Gr of Gra avity vity OutdoorUnits CXC24SCB AC024BXSCCC AA Units mm inches Units mm inches CXC18SCB AC018BXSCCC AA ...

Страница 74: ...3 Centerof Gravity OutdoorUnits CXC30SCB AC030BXSCCC AA CXC36SCB AC036BXSCCC AA Units mm inches ...

Страница 75: ...r EMI PCB Printed circuit board EMI OLP TEMP Thermistor OLP NOTE This wiring diagram applies only to the outdoor unit Colors blk black red red blu blue wht white yel yellow brn brown sky skyblue When operating don t short circuit the protection device High Pressure switch For connection wiring indoor outdoor transmission F1 F2 outdoor outdoor transmission OF1 OF2 refer to the installation manual P...

Страница 76: ... Check NOTE This wiring diagram applies only to the outdoor unit Colors blk black red red blu blue wht white yel yellow brn brown sky skyblue When operating don t shortcircuit the protection device High Pressure switch For connection wiring indoor outdoor transmission F1 F2 outdoor outdoor transmission OF1 OF2 refer to the installation manual Protective earth screw connector The wire quantity ...

Страница 77: ...pressure level is obtained in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment Sound pressure level may differ depending on operation condition dBA A weighted sound pressure level Reference acoustic pressure 0 dB 20μPa CXC30SCB AC030BXSCCC AA 52 CXC36SCB AC036BXSCCC AA 54 2 CXC24SCB AC024BXSCCC AA NC Curve 1 CXC18SCB AC018BXSCCC AA 3 CXC3...

Страница 78: ... a sound source generates dBA A weighted sound power level Reference power 1pW Measured according to ISO 3741 Unit dB A Model Cooling CXC18SCB AC018BXSCCC AA CXC24SCB AC024BXSCCC AA 62 CXC30SCB AC030BXSCCC AA CXC36SCB AC036BXSCCC AA 65 67 69 2 CXC24SCB AC024BXSCCC AA NC Curve 1 CXC18SCB AC018BXSCCC AA 3 CXC30SCB AC030BXSCCC AA 4 CXC36SCB AC036BXSCCC AA ...

Страница 79: ...2 65 6 82 0 98 4 65 6 0 97 0 96 0 95 49 2 0 98 0 97 0 96 0 95 32 8 0 99 0 98 0 97 0 96 0 95 16 4 1 00 0 99 0 98 0 97 0 96 0 95 0 0 1 00 0 99 0 98 0 97 0 96 0 95 16 4 1 00 0 99 0 98 0 97 0 96 0 94 32 8 0 98 0 97 0 96 0 95 0 93 49 2 0 97 0 96 0 95 0 92 65 6 0 96 0 94 0 91 Level Difference ft Pipe Length ft ...

Страница 80: ... 94 0 93 0 92 0 91 0 90 32 8 0 99 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 16 4 1 00 0 99 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 0 0 1 00 0 99 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 16 4 1 00 0 98 0 97 0 96 0 95 0 94 0 93 0 92 0 90 0 88 32 8 0 98 0 97 0 96 0 95 0 94 0 92 0 91 0 89 0 87 49 2 0 97 0 96 0 94 0 93 0 92 0 90 0 88 0 85 65 6 0 96 0 94 0 93 0 91 0 89 0 87 0 83 82 0 0 94 0 92 0 91 0 89 0 ...

Страница 81: ...90 49 2 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 32 8 0 99 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 16 4 1 00 0 99 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 0 0 1 00 0 99 0 98 0 97 0 96 0 94 0 93 0 92 0 91 0 90 16 4 1 00 0 98 0 97 0 96 0 95 0 94 0 93 0 92 0 90 0 88 32 8 0 98 0 97 0 96 0 95 0 94 0 92 0 91 0 89 0 87 49 2 0 97 0 96 0 94 0 93 0 92 0 90 0 88 0 85 65 6 0 95 0 94 0 93 0 91 0 89 0 87 0 83 82 ...

Страница 82: ... Outdoortemperature Indoor humidity Cooling 18 to 32 64 to 90 40 to 50 40 to 122 80 or less Drying 18 to 32 64 to 90 40 to 50 40 to 122 NOTE The assumed installation conditions are follows The pipe length including elbow is 7 5m 24 6ft The level difference is 0 m 80 or less ...

Страница 83: ...ion Valve Main E_M Thermistor Discharge pipe T_D Thermistor Compressor Top T_CT Heat Exchanger Main Outdoor unit HX_M Thermistor IDU Heat Exchanger Mid T_IM Thermistor Ambient T_A Thermistor CondOut T_CO Thermistor IDU Heat Exchanger IN T_II Outdoor Fan Motor1 OFM1 Heat Exchanger Indoor unit HX_ID INDOOR UNIT OUTDOOR UNIT Thermistor Indoor Room T_IR Indoor Fan Motor IFM ...

Страница 84: ...oor unit HX_M Thermistor IDU Heat Exchanger Mid T_IM Thermistor Ambient T_A Thermistor CondOut T_CO Thermistor IDU Heat Exchanger IN T_II Outdoor Fan Motor1 OFM1 Heat Exchanger Indoor unit HX_ID INDOOR UNIT CNH244DB AC024BN4DCH AA CXC24SCB AC024BXSCCC AA CNH304DB AC030BN4DCH AA CXC30SCB AC030BXSCCC AA CNH364DB AC036BN4DCH AA CXC36SCB AC036BXSCCC AA OUTDOOR UNIT Accumulator AC Thermistor Indoor Roo...

Страница 85: ...sulation or a similartype of insulation to the body of the indoor unit Do not install the airconditionerin following places A place with exposure to mineral oil oil vapour or cooking area where there is spray If oil adheres to the heat exchanger performance degradation spray or condensation scattering may occur If oil adheres to a plastic component the component may deform or get damaged Such issu...

Страница 86: ...ceiling when temperature is over80 6 F 27 C and humidity is over80 you must apply an extra10 mm thick polyethylene insulation ora similartype of insulation to the body of the indoorunit Cut away the part where pipes are pulled out forthe insulating work 4 way Cassette B D A E C Insulate the end of the pipe and some curved area by using separate insulator NOTE A Reference forthe outer circumference...

Страница 87: ...h of each attached suspension bolt If the length of the suspension bolt is more than 4 92ft 1 5m vibration prevention is recommended If this is not possible create an opening on the false ceiling in orderto be able to use it to perform the required operations on the indoor unit 4 Screw eight nuts and washers to the suspension bolts making space for hanging the indoor unit CAUTION You must install ...

Страница 88: ...ain hose and drain pipe 1 Push the supplied drain hose as far as possible over the drain socket 2 Tighten the metal clamp as shown in the picture 3 Wrap the supplied large sealing pad overthe metal clamp and drain hose to insulate and fix it with clamps 4 Insulate the complete drain piping inside the building field supply If the drain hose cannot be sufficiently set on a slope fit the hose with dr...

Страница 89: ...the hose an upward gradient beyond the connection port This will cause waterto flow backwards when the unit is stopped resulting in water leaks Under gradient Ceiling Do not apply force to the piping on the unit side when connecting the drain hose The hose should not be allowed to hang loose from its connection to the unit Fasten the hose to a wall frame or other support as close to the unit as po...

Страница 90: ...he main drain pipe To prevent waterfrom flowing back to indoorunits install an individual airvent at the top of each indoorunit The airvents should be T or 7 shaped to prevent dust orforeign substances from entering You may not need to install an airvent if the horizontal drain pipe has a proper slope Connecting the powerand communication cables Bushing bracket installation When connecting the pow...

Страница 91: ...means of a H05 RN F connection cable or a more power model with insulation in synthetic rubber and a jacket in polychloroprene neoprene in accordance with the requirements specified in the standard EN 60335 2 40 1 Remove the screw on the electrical component box and remove the cover plate 2 Route the connection cord through the side of the indoor unit and connect the cable to the terminals referto...

Страница 92: ...en it with a clamp The unbalanced power must be maintained within10 of supply rating among whole indoor units If the power is unbalanced greatly it may shorten the life of the condenser If the unbalanced power is exceeded by more than10 of supply rating the indoor unit will protect itself by stopping and displaying an error code Connect the power cable to the auxiliary circuit breaker An all pole ...

Страница 93: ...at an height of between 7 2 8 2 ft 2 2 2 5m from the ground if the unit has a duct with a well defined length 11 81inch 300 mm ormore to avoid fan motorblowercontact If you install the cassette orduct type indoorunit on the ceiling with humidity over80 you must apply extra 0 39 inch 10mm of polyethylene foam orotherinsulation with similarmaterial on the body of the indoorunit Optional Insulating t...

Страница 94: ...pening on the false ceiling in order to be able to use it to perform the required operations on the indoor unit Ceiling support 4 Screw eight nuts to the suspension bolts making space for hanging the indoorunit NOTE You must install all the suspension rods 5 Hang the indoorunit to the suspension bolts between two nuts CAUTION Piping must be laid and connected inside the ceiling when suspending the...

Страница 95: ...79inch 20mm ormore 2 Install horizontal drainpipe with a slope of1 100 ormore and fix it by hangerspace of 3 28 4 92ft 1 1 5m 3 Install the airvent in the horizontal drainpipe to prevent water flow back to the indoorunit NOTE You may not need to install it if there were proper slope in the horizontal drainpipe 4 The flexible hose should not be installed upward position it may cause waterflow back ...

Страница 96: ...N 60335 2 40 1 Remove the screw on the electrical component box and remove the coverplate 2 Route the connection cord through the side of the indoorunit and connect the cable to the terminals referto the figure below 3 Route the otherend of the cable to the outdoorunit through the ceiling the hole on the wall 4 Reassemble the electrical component box cover carefully tightening the screw AC BNHDCH ...

Страница 97: ...ble cord Code designation 1 phase IEC 60245 IEC 57 CENELEC H05RN F grade ormore Be sure to run the powersupply cable and the communication cable through electrical conduit as seen in the picture AC BNHDCH Conduit CAUTION Be sure not to put yourfinger into the conduit Since it has the external power supply refer to the outdoor unit installation manual for MAIN POWER CAUTION When installing the indo...

Страница 98: ...rainwaterfrom getting inside through the insulation CAUTION 3 94 100 ormore recommended Unit inch mm 4 92 125 ormore recommended NOTE The appearance of the unit may be different from the diagram depending on the model Attaching the mounting bracket to the wall 1 Hold the mounting bracket against the wall at the selected installation position in Step 2 making sure that the screw holes align with th...

Страница 99: ...fore the refrigerant pipes Two short refrigerant pipes are alreadyattached to the air conditioner The smaller diameter pipe is for the high pressure two phase refrigerant The larger diameter pipe is for the low pressure refrigerant vapor Refrigerant pipes assembly pipe Connection hose Drain hose In Step 4 you determined the exit position forthe piping bundle The unit has three knockouts available ...

Страница 100: ...e 3 Connect a 0 63inch 15 88mm ID extension drain hose to the main drain hose CAUTION If the diameter of the connection hose is smaller than the product s drain hose leakage may occur A B 40 45 mm Drain hose A Drain hose Extension drain hose 1 57 1 97inch 40 45mm 0 79inch 20mm ormore Vinyl tape Foam insulation Extension drain hose B 4 Do not box in orcoverthe drain hose connection It must be acces...

Страница 101: ... cm Powersupplycords of parts of appliances foroutdooruse shall not be lighterthan polychloroprene sheathed flexible cord Code designation IEC 60245 IEC 57 CENELEC H05RN F Since it has the external power supply refer to the outdoor unit installation manual for MAIN POWER CAUTION When installing the indoor unit in a computer room or network room use the double shielded communication cable tape alum...

Страница 102: ...mmended 4 92 inch 125 mm ormore recommended Drain hose hole You can select the direction of draining left orright Maximum pipe height 26 25 ft 8 m Maximum pipe length 49 21 ft 15 m Make a U trap A on the pipe which is connected to the indoor unit at outerwall and cut the bottom part of the insulation about 0 39 inch 10 mm to prevent rainwaterfrom getting inside through the insulation OutdoorUnit O...

Страница 103: ...is may lmead to physical injury or equipment damage Search for other spots if there are less than two studs or the distance between the studs are different from the plate hanger Fix the installation plate without inclining to one side Connecting the refrigerant pipe Connect indoorand outdoorunits with field supplied copperpipes by means of flare connections Use insulated seamless refrigeration gra...

Страница 104: ...Too small clearance 2 Pourwaterinto the drain pan Check whetherthe hose is well drained CAUTION Make sure that the indoor unit is in upright position when you pourwater to check for leakage Make sure that the water does not overflow onto the electrical part If the diameter of the connection hose is smaller than the product s drain hose water leakage may occur Inadequate installation may cause wate...

Страница 105: ... in the standard EN 60335 2 40 1 Remove the screw on the electrical component box and remove the coverplate 2 Route the connection cord through the side of the indoor unit and connect the cable to the terminals referto the figure below 3 Route the otherend of the cable to the outdoorunit through the ceiling the hole on the wall 4 Reassemble the electrical component box cover carefully tightening t...

Страница 106: ...ve just purchased a system air conditioner and it has been installed byyour installation specialist This device must be installed according to the national electrical rules Ifyouroutdoorunitexceedsanetweightof132 2lb 60kg donotinstallitonasuspendedwall butstanditonafloor The reliability of our product cannot be guaranteed under conditions of A or less OutdoorModel A AC018 024BXSCCC AC030 036BXSCCC...

Страница 107: ...upplied by SAMSUNG Code MOK 220SA or commercial water repellent grease and wax etc based on the product condition When the product is to be shut down for a long period of time such as off peak hours take appropriate measures like covering the product If the product installed within1640 4 ft of seashore special anti corrosion treatment is required Please contact your local SAMSUNG representative fo...

Страница 108: ...23 62 600 ormore 23 62 600 ormore 59 06 1500 or more 23 62 600 ormore 23 62 600 ormore 23 62 600 ormore 11 81 300 ormore 11 81 300 or more 11 81 300 ormore 11 81 300 ormore 19 69 500 or more 19 69 500 or more CAUTION The outdoor unit must be installed according to the specified distances in orderto permit accessibility from each side to guarantee correct operation maintenance and repair of the uni...

Страница 109: ...he ground wire forthe telephone line cannot be used to ground the air conditioner 3 DIf the outdoor unit is exposed to strong winds install shield plates around the outdoor unit so that the fan can operate correctly NOTE Install provided rubber legs to prevent vibration and noise AC018 024BXSCCC Unit inch mm Anchorbolt hole 26 02 661 14 06 357 13 31 338 14 13 359 34 65 880 AC030 036BXSCCC Unit inc...

Страница 110: ... wire conduits When connecting cables between the indoor unit and the outdoor unit use conduits to protect the cables 1 Drill holes on the conduit plate in accordance with their use and quantity AC018 024BXSCCC Drill conduit holes on the side cabinet knock out holes Conduit Holes AC030 036BXSCCC Use a nipperto remove conduit holes from the lowerpart of the cabinet Do not remove it by hammering Con...

Страница 111: ...CCB Outdoorto indoor powercable 1 L ELB Cable clamp 2 N IndoorUnit Main power cable L F1 Electrical component box Communication cable N When using ELB forAC030 036BXSCCC 1 phase Cable tie MCCB Communication cable IndoorUnit Outdoorto indoor powercable ELB Electrical component box Main power cable The appearance of the unit maybe different from the picture depending on the model Powersupply 1 L 2 N...

Страница 112: ... all poles with contact gap of a least 0 12 inch 3mm Devices disconnected from the power supply should be completely disconnected in the condition of overvoltage category Keep distances of1 97 inch 50mm or more between power cable and communication cable Main powerterminal block specifications AC018 024BXSCCC 1 phase Unit inch mm AC power M4 screw 1 L L F1 0 64 16 3 0 40 10 1 Communication M4 scre...

Страница 113: ... FAN2 A FAN A AC018BXSCCC AC018BN4DCH 208 230V 60Hz 8 2 0 97 0 79 13 5 15 0 AC018BNADCH 0 42 AC018BNHDCH 2 10 AC024BXSCCC AC024BN4DCH 13 5 0 97 0 79 AC024BNADCH 0 42 20 1 25 0 AC024BNHDCH 2 10 AC030BXSCCC AC030BN4DCH 16 2 0 97 0 79 AC030BNHDCH 2 10 23 5 30 0 AC030BNTDCH 0 51 AC036BXSCCC AC036BN4DCH 16 2 0 97 0 79 AC036BNHDCH 3 50 24 9 30 0 AC036BNTDCH 0 51 ...

Страница 114: ...ge Units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits Maximum allowable voltage variation between phases is 2 Wire size type must complywith the applicable local and national code Wire size Based on the value of MCA Wire type 1 phase 60245 IEC57 IEC or H05RN F CENELEC grade or more Silence mode controllerwiring diagram...

Страница 115: ...wiring so that the front cover does not rise up when doing wiring work and attach the front cover securely Ground wire forthe indoor unit and outdoor unit connection cable must be clamped to a soft copper tin plated eyelet terminal with M4 screw hole NOT SUPPLIED WITH UNITACCESSORIES The appearance of the unit may be different from the picture depending on the model Outdoor to indoorpowerterminal ...

Страница 116: ...5 0 0 1 8 0 07 8 3 16 22 7 8 13 1 2 43 1 11 16 8 4 1 3 16 50 0 07 8 3 16 22 7 8 0 3 0 011 13 5 1 2 0 5 0 019 0 2 0 007 11 4 7 16 0 3 0 011 17 5 11 16 14 9 16 50 2 8 4 1 3 16 0 4 0 015 0 0 1 8 0 07 70 0 10 8 3 16 24 1 0 4 0 015 17 5 11 16 0 5 0 019 0 4 0 015 13 3 1 2 20 0 4 18 5 3 4 3 4 0 015 51 2 8 4 1 3 16 0 4 0 015 0 0 2 0 0 078 Connect the rated cables only Connect using a driverwhich is able t...

Страница 117: ...0245 IEC 57 CENELEC H05RN F When installing the indoorunit in a computerroom or network room use the double shielded tape aluminum polyesterbraid copper cable of FROHH2R type Indoorpowersupply Powersupply Max Min V Indoorpowercable 1Φ 208 230V 60Hz 10 0 0012 inch 0 75mm2 3 wires Communication cable 0 0012 inch 0 75mm2 2 wires Indoorunit 4WAY CST AC BN4 Mini4way CST AC BNN Indoor unit Duct AC BNL A...

Страница 118: ...Head Office Suwon Korea 129 Samsung Ro Yeongtong Gu Suwon City Gyeonggi Do Korea 16677 Website www samsung com https partnerhub samsung com Email airconditioner samsung com Images and data in this book may subject to change without prior notice ...

Отзывы: