Alignment & Troubleshooting
Service Manual
4-33
Samsung Electronics
● Code
02-001
02-006
● Error message
Error :#02-001 Please turn off then on.
● Symptom
At Warm-up, this error has occurred. The machine does not work until power off/on.
● Possible Cause
Fuser Unit is not installed and AC is not supplied to the Heat Lamp.
● Troubleshooting method
1. Turn off the power. And turn on the power.
2. Check the connection of the Fuser AC on FDB
②
.
3. Check the Fuser control harness
①
.
4. Remove the resistance value of the thermostat. If the value is infinite, replace the thermostat.
5. If the problem persists, replace the Fuser unit.
6. Replace the SMPS board or FDB (Fuser drive board).