Alignment & Troubleshooting
Service Manual
4-32
Samsung Electronics
● Code
02-000
● Error message
Error :#02-000 Please turn off then on.
● Symptom
At Warm-up, this error has occurred. The machine does not work until power off/on.
● Possible Cause
Fuser Unit is not installed and AC is not supplied to the Heat Lamp.
● Troubleshooting method
1. Turn off the power. And turn on the power.
2. If the problem persists, replace the fuser unit.
3. If the problem persists after replacing the fuser unit, reconnect the CN35 connector on Main-PBA.
4. If the problem persists, replace the Main-PBA.
CN35
→
Thermistor
CN35
→
Thermistor