- 38 -
No Power
Replace PCB or display PCB check
YES
YES
YES
- Check terminal block voltage, 230V.
Reset The circuit braker or
Check main power
NO
- TCO open Check
(main TCO, Convection TCO)
Replace TCO
NO
- Check the input voltage of PCB
SMPS (input checkpoint : 230V )
Repair Faulty wiring
NO
4-1-11 Power Failure