ENGLISH-17
03
O
THERS
Cleaning the sensor
Carefully clean the lens and the gas sensor with a
cotton swab.
Dust sensor
lens
Gas
sensor
Insert the hooks of the back cover into the grooves at the bottom of the main body (
①
) and press the edges of the back
cover so that it fits into 8 holes (
②
) of the main body.
Back cover
②
①
When the air purifier is not operating, hold the left
and right edges of the back cover, pull it forward
slightly (
①
) and then lift it up (
②
) to separate it.
①
②
Dust sensor
Gas sensor
CAUTION
• Do not clean the sensors using volatile substances (alcohol, acetone, etc.). Use only water.
• If the dust sensor lens or the gas sensor is contaminated by a foreign substance (dust), the cleanness indicator of
the air purifier may be stuck in the polluted state. In this case, clean the sensors.
• Clean the sensors at least once every 6 months. However, cleaning period should be different depending on the
operating environment and the operating time. Therefore cleaning should be more often in places with lots of
dusts.
• Cleanness indicator on the control panel may not change from polluted state when the air purifier is operating
in place with heavy dusts or smells that may be beyond its capability.
(In this case, open the window to ventilate, or use the air purifier with appropriate capacity.)
• Do not use any spray type product near the air purifier.
• Turn off the power when cleaning the sensors. If you clean the sensors while the power is on, misdetection may
occur from the sensor and the cleanness indicator may not work properly.