Adjusting the Air Flow Direction
Temperature and Humidity Ranges
E-
10
The following table indicates the temperature and humidity ranges,
within which the air conditioner can be used.
If the air conditioner is used at...
Then...
The automatic protection feature may be
triggered and the air conditioner stopped.
High temperature
A water leakage or some other
malfunction may happen if the heat
exchanger freezes.
Low temperature
Water may condense on and drip from
the surface of the indoor unit if it is used
for a long periods.
High humidity levels
❇
The standardized temperature for heating is 7°C. If the outdoor
temperature drops to 0°C or below, the heating capacity can be
reduced depending on the temperature condition.
If the cooling operation is used at over 32°C(indoor temperature),
it does not cool at its full capacity.
Mode
Indoor Temperature
Outdoor Temperature
Indoor Humidity
Heating
Cooling
Drying
27°C or less
21°C to 32°C approx.
21°C to 32°C approx.
-15°C to 24°C approx.
-5°C to 43°C approx.
-5°C to 43°C approx.
-
80% or less
-
There are two sets of inner air flow blades. Just as the outer air flow blade
can be adjusted vertically, the inner blades can be adjusted horizontally.
Adjust each set of inner blades to the required position, by pushing or
pulling them sideways.