E-
11
ENGLISH
The following table indicates the temperature and humidity ranges,
within which the air conditioner can be used.
If the air conditioner is used at... Then...
High temperature
The automatic protection feature may be
triggered and the air conditioner stopped.
Low temperature
Water leakage or some other malfunction
may happen if the heat exchanger freezes.
High humidity levels
Water may condense on and drip from the
surface of the indoor unit if it is used for
a long period.
Mode
Outdoor Temperature
Indoor Temperature
Indoor Humidity
Heating
5°F to 75°F approx.
81°F or less
-
Cooling
23°F to 109°F approx.
64°F to 90°F approx.
80% or less
Drying
23°F to 109°F approx.
64°F to 90°F approx.
-
Temperature and Humidity Ranges
If the heating operation is used at below 32°F(outdoor temperature) then,
it does not heat at its full capacity. If the cooling operation is used at
over 91°F(indoor temperature) then,it does not cool at its full capacity.
AVXDD_E_05587A-2.indd 11
2006-09-18 ソタネト 1:19:51
Содержание AVMDH
Страница 9: ...E 9 ENGLISH IndoorUnit AVMHH Air outlet Air inlet ...