background image

26_

 cleaning and maintaining

cleaning and maintaining the 

air conditioner

  

Make sure the power is turned off and unplugged from the wall socket when cleaning the air  

 

conditioner. 

If system contains 3 kg or more of fluorinated greenhouse gases. In this case, it has to be checked for 
leakage at least once every 12 months, according to regulation n°842/2006. This activity has to be covered 
by qualified personnel only.
In the case above, a maintenance book has to be available for each unit installed.

CLEANING THE EXTERIOR

1. 

Wipe the surface of the unit with a slightly wet or dry 
cloth when needed. 

Do not use Benzene, Thinner or Clorox

TM

.

They may damage the surface of the air conditioner 
and can create a risk of fire.

CLEANING THE FILTER

When cleaning the filter, make sure to unplug the power from the unit. No special tools are needed to clean it.

Air filter

Washable foam based air filter captures large particles from the air. The filter is cleaned with a 
vacuum or by hand washing. 

1. 

Open the front panel.

 

Tightly grab front side of the front panel and lift up the panel to open. Then slightly push the 
panel up until the panel is hanged over the hooks of the unit.

2. 

Grab the handle and lift it up. Then, pull the Air filter towards you and slide it down. 

3. 

Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with 
running water and dry it in a ventilated area.

• 

For the best conditions, repeat every two weeks.

• 

If the Air filter dries in a confined(or humid) area, odors may generate. If it occurs, 

re-clean and dry it in a well-ventilated area.

4. 

Insert the Air filter back in its original position.

5. 

Close the front panel.

CAUTION

Air filter

CAUTION

MID_AS09U series_IB_30920A_E_9.09.09.indd   26

2009-9-23   9:54:32

Содержание AS18UUAX

Страница 1: ...o exhausting hot summer days and lets you rest Beat the heat with your own air conditioner this summer Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your spa...

Страница 2: ...www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in...

Страница 3: ...ower cable or loosened power receptacle Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner Potential risk of electric shock...

Страница 4: ...le concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the...

Страница 5: ...shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner Potential risk of electric shock...

Страница 6: ...material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical wast...

Страница 7: ...ntenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indic...

Страница 8: ...tem APPENDIX 29 29 Troubleshooting 30 Operation ranges contents VIEWING YOUR AIR CONDITIONER 10 10 Checking the indoor unit and display 10 Main parts 10 Display 11 Opening the front panel 11 Power but...

Страница 9: ...k your air conditioner and check the indoor unit to make sure it is not damaged Main parts Display Your air conditioner may slightly look different from illustration shown above depending on your mode...

Страница 10: ...check the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power button The room temperature sensor measures indoor room temperature Make sure roo...

Страница 11: ...4 17 for instructions Fan Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto Low Medium High Air swing Activate Deactivate air flow blade movement autom...

Страница 12: ...e location of remote control receiver When you properly press the button on the remote control you will hear beep sound from the indoor unit The signal may not be received well of electronic lighting...

Страница 13: ...ontrol 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote control display The air conditioner will automatically set...

Страница 14: ...mperature You can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set t...

Страница 15: ...operates in Dry mode and automatically adjust the fan speed to Auto Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan 3 Set the temperature Press the Temp or b...

Страница 16: ...Fan mode and circulate the indoor air Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan 3 Set the fan speed Press the Fan or button on the remote control to se...

Страница 17: ...on on the remote control again to keep the air flow direction in a constant position Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blades are not broken 1 Mov...

Страница 18: ...n last used mode or in Auto mode if Dry Fan mode is most recent mode used Turbo function is only available in Auto Cool mode If Turbo function is selected in Dry Fan mode operating mode changes to Aut...

Страница 19: ...t Cancel button on the remote control to active it on The remote control display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will opera...

Страница 20: ...3 hours 3 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set for 3 seconds and set desired temperature will display The air...

Страница 21: ...f the On Timer is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2 hours and then tu...

Страница 22: ...the time setting while Off timer indicator is blinking You can set the time up to 12 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 4 Press the Set Canc...

Страница 23: ...erature Sound sleep Relaxes your body and raises your temperature slightly Wake up from mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh Set Off timer in mode...

Страница 24: ...Cool mode When Smart Saver function is activated temperature range will be limited to 24 C 30 C If the desired temperature is lower than 24 C turn off the Smart Saver function by pressing the Smart Sa...

Страница 25: ...o unplug the power from the unit No special tools are needed to clean it Air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand...

Страница 26: ...nsate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric com...

Страница 27: ...e unit control system This internal protection operates if an internal fault occurs in the air conditioner Type Description Protect compressor The air conditioner does not start operating immediately...

Страница 28: ...ck if the air conditioner has just been turned on If so wait 3 minutes The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to A...

Страница 29: ...to 43 C 15 C to 54 C AS12 18 24UUAMID 80 or less Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor DRYING 18 C to 32 C 15 C to 43 C 15 C to 54 C...

Страница 30: ...memo _31 MID_AS09U series_IB_30920A_E_9 09 09 indd 31 2009 9 23 9 54 40...

Страница 31: ...e product is used in lran QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT CHILE 800 SAMSUNG 726 7864 www samsung com cl TURKEY 444 77 11 www samsung com tr SOUTH AFRICA 0860 SAMSUNG 726 7864...

Страница 32: ...purchasing this Samsung product To receive more complete service please register your product at www samsung com global register AS09U Series AS12U Series AS18U Series AS24U Series DB98 30920A 2 A F...

Отзывы: