Connecting the Cables to the Outdoor Unit
One electric cable must be connected to the outdoor unit:
◆
The assembly cable connecting the indoor unit to the outdoor unit
1
Remove the terminal board cover on the side of the outdoor unit.
2
Connect the assembly cable to terminals N to 2.
➢
It is recommand that the conduit kit for power supply
to the outdoor unit be installed between auxillary
power S/W and the outdoor unit.
(The conduit kit is optional)
3
Connect the earth wires to the earth terminals.
➢
Refer to the page opposite for further details on how to check
that earthing is correct, refer to page 36.
4
Replace the terminal board cover, carefully tightening the screw.
5
Connect the assembly cable with the indoor unit.
1 2 3 4 5
N L 1 2
1
4
3
2
N
L
1
2
3
Indoor unit
Outdoor unit
I
NSTALLING THE
O
UTDOOR
U
NIT
E-
34