Reference Sheet
14-10
Samsung Electronics
14-7-2 "Pump down" Procedure
Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.
3-Way Valve
2-Way Valve
1) Remove the caps from the 3-Way valve and the
3-Way valve.
3) Set the unit to cool operation mode.
(Check if the compressor is operating.)
4) Turn the 3-Way valve clockwise to close.
7) Close the cap of each valve.
2) Turn the 3-Way valve clockwise to close and
connect a pressure gauge(low pressure side)
to the service valve, and open the 3-Way valve
again.
5) When the pressure gauge indicates "0" turn the
3-Way valve clockwise to close.
6) Stop operation of the air conditioner.
Relocation of the air conditioner
• Refer to this procedure when the unit is relocated.
• Carry out the pump down procedure(refer to the details of 'pump down').
• Remove the power cord.
• Disconnect the assembly cable from the indoor and outdoor units.
• Remove the flare nut connecting the indoor unit and the pipe.
• At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
• Disconnect the pipe connected to the outdoor unit.
At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
• Make sure you do not bend the connection pipes in the middle and store together with the cables.
• Move the indoor and outdoor units to a new location.
• Remove the mounting plate for the indoor unit and move it to a new location.
24437A(1)_1 1/16/05 9:58 PM Page 12-37
Содержание AS09HPB
Страница 30: ...MEMO Samsung Electronics 5 4...
Страница 34: ...MEMO Samsung Electronics 5 8...
Страница 35: ...Samsung Electronics 5 9 5 4 Ass y Control Out AS09BPAX DB93 03450B AS12BPAX DB93 03450A...
Страница 46: ...Samsung Electronics 7 2 This Document can not be used without Samsung s authorization 7 2 Outdoor Unit...
Страница 48: ...Samsung Electronics 8 2 8 2 Outdoor Unit This Document can not be used without Samsung s authorization...
Страница 80: ...MEMO 12 23 Samsung Electronics...
Страница 82: ...13 2 Samsung Electronics Block Diagram INDOOR FAN CONTROL SMPS AC COMMUNICATION SUB PCB BUZZER CONTROL...
Страница 84: ...Block Diagram 13 4 Samsung Electronics DC_LINK CAP B D DIODE IPM OUTDOOR FAN SMPS IGBT...
Страница 95: ...MEMO Samsung Electronics 14 11...