Troubleshooting
Samsung Electronics
12-18
12-2-16 DC Link Over voltage/ Low voltage error
1. Checklist :
1) Is the power voltage normal?
2) Is the voltage of front and back terminal of indoor(outdoor) power relay normal?
3) Is the resistance value for DC Link voltage detection NORMAL?
4) Is the resistance value of DC Link discharge normal?
5) Is the appearance of DC Link Capacitor normal?
2. Troubleshooting procedure
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Restart after power off.
Terminate the service.
No
No
Is the DC Link voltage error occurred again?
Terminate the service.
Is the power voltage normal?
Exchange the PCB.
No
Is the front and back terminal voltage of
indoor/outdoor power relay normal?
Exchange the PCB.
No
Is the appearance of
DC Link Capacitor normal?
Exchange the PCB.
No
Is the resistance for the
detection of DC Link voltage normal?
Exchange the PCB.
No
Is the resistance value of
DC Link discharge normal?
Exchange the PCB.
No
Is the reactor insulation damaged?
Exchange the reactor.
Reassembly the PCB.
24437A(1)_1 1/16/05 9:58 PM Page 12-18
Содержание AS09BPA
Страница 30: ...MEMO Samsung Electronics 5 4 ...
Страница 34: ...MEMO Samsung Electronics 5 8 ...
Страница 35: ...Samsung Electronics 5 9 5 4 Ass y Control Out AS09BPAX DB93 03450B AS12BPAX DB93 03450A ...
Страница 46: ...Samsung Electronics 7 2 This Document can not be used without Samsung s authorization 7 2 Outdoor Unit ...
Страница 48: ...Samsung Electronics 8 2 8 2 Outdoor Unit This Document can not be used without Samsung s authorization ...
Страница 80: ...MEMO 12 23 Samsung Electronics ...
Страница 82: ...13 2 Samsung Electronics Block Diagram INDOOR FAN CONTROL SMPS AC COMMUNICATION SUB PCB BUZZER CONTROL ...
Страница 84: ...Block Diagram 13 4 Samsung Electronics DC_LINK CAP B D DIODE IPM OUTDOOR FAN SMPS IGBT ...
Страница 95: ...MEMO Samsung Electronics 14 11 ...