background image

What are systolic pressure and diastolic pressure? 

press

artery

vein

blood discharging

Systolic

relax

blood entering

Diastolic  

When ventricles contract and pump blood out 
of the heart, the blood pressure reaches its 
maximum value in the cycle, which is called 
systolic pressure. When the ventricles relax, 
the blood pressure reaches its minimum value 
in the cycle, which is called diastolic pressure.

Irregular Heartbeat Detector

CAUTION

The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular 
heartbeat was detected during measurement. Usually this is NOT a cause for concern. 
However, if the symbol appears often, we recommend you seek medical advice. Please note 
that the device does not replace a cardiac examination, but serves to detect pulse irregularities 
at an early stage. 

An irregular heartbeat is detected when a heartbeat rhythm varies while the device is 
measuring systolic pressure and diastolic pressure. During each measurement,  
SAMSUNG ARM BPM will keep a record of all the pulse intervals and calculate the 
average value of them. If there are two or more pulse intervals, the difference 
between each interval and the average is more than the average value of ±25%, or 
there are four or more pulse intervals, the difference between each interval and the 
average is more than the average value of ±15%, then the irregular heartbeat symbol 
will appear on the display with the measurement result.

Why does my blood 
pressure fluctuate 
throughout the day?

Is the result the same 
if measuring on the 
right arm?

Why do I get a different 
blood pressure at home 
compared to the hospital?

1. Individual blood pressure varies 

multiple times everyday. It is also affected 
by the way you tie your cuff and your 
measurement position, so please take the 
measurement under the same conditions.

2.If the person takes medicine, the 

pressure will vary more.

3.Wait at least 3 minutes for another 

measurement.

The blood pressure is different even 

throughout the day due to weather, 
emotion, exercise etc, Also, there is the 
“white coat” effect, which means blood 
pressure usually increases in clinical 
settings.

It is ok for both arms, but there will 

be some different results for 
different people. We suggest you 
measure the same arm every time.

What you need to pay attention to 

when you measure your blood 
pressure at home: 

If the cuff is tied properly. 
If the cuff is too tight or too loose.
If the cuff is tied on the upper arm.
If you feel anxious.
Taking 2-3 deep breaths before 

beginning will be better for measuring.        

Advice: Relax yourself for 4-5 

minutes until you calm down.

What is the standard blood pressure classification?

Only a physician can tell your normal BP range.
Please contact a physician if your measuring 
result falls out of the range. Please note that 
only a physician can tell whether your blood 
pressure value has reached a dangerous point.

The blood pressure classification published by 

World Health Organization (WHO) and 

International Society of Hypertension (ISH) in 

1999 is as follows:

CAUTION

SYS

DIA

<120

<80

120-129

80-84

130-139

85-89

140-159

90-99

160-179

100-109

≥180

≥110

Level

Blood

Pressure (mm Hg) 

Optimal

Normal

High-normal

Mild

Moderate

Severe

17

16

ABOUT BLOOD PRESSURE

ABOUT BLOOD PRESSURE

Содержание ARM BPM

Страница 1: ...nal Components of the Device List BEFORE YOU START 8 The Choice of Power Supply Installing and Replacing the Batteries Install the App and Pair Up Search your test information D MEASUREMENT 11 Tie the Cuff Taking a Measurement INFORMATION FOR USER 14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 16 What are systolic pressure and diastolic pressure What is the standard blood pressure class...

Страница 2: ...uthority or retailer for recycling advice Caution These notes must be observed to prevent any damage to the device SN Symbol for MANUFACTURE DATE Symbol for Authorised Representative in the European Community EC REP CAUTION This device is intended for adult use in homes only The device is not suitable for use on neonatal patients pregnant women patients with implanted electronical devices patients...

Страница 3: ...nd charge power under normal circumstances and maintain the The service life of the cuff may vary by the frequency of washing skin condition and storage state The typical service life is 10000 times It is recommended that the performance should be checked every 2 years and after maintenance and repair by retesting at least the requirements in limits of the error of the cuff pressure indication and...

Страница 4: ...OCUMENTS Wireless communications equipment such as wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance d away from the equipment The distance d is calculated by the MANUFACTURER from the 80MHz to 5 8 GHz column of Table 4 and Table 9 of IEC 60601 1 2 2014 as appropriate Please use AC...

Страница 5: ...to the environment Do not dispose with daily garbage Remove the old batteries from the device following your local recycling guidelines Install the App and Pair Up Download the SAMSUNG HEALTH app from APP Store or Google Play Install the APP and register an account Click Manage items add Blood pressure and then click Save Click choose Accessories click Scan for accessories and add Samsung Arm Bpm ...

Страница 6: ...y Range 2402MHz to 2480MHz Output Power Range 0 dBm Supply Voltage 4 0 7 2V Transmitting Distance 10 meters Settinging the User 1 When the monitor is off press the START STOP button to turn on the monitor and it will show the current user Long press the START STOP button agin to switch the user There are 3 user intotal and guest mode User mode store 60 grops message guest mode doesn t store messag...

Страница 7: ...e daily measurements at approximately the same time on the same arm or as directed by a physician Take the measurement in a silent room The cuff should maintain at the same level as the right atrium of the heart Please sit comfortably Do not cross your legs and keep your feet flat on the ground Keep your back against the backrest of the chair Tip You can press START STOP button at any time to stop...

Страница 8: ...g When talking or moving your fingers When you want to discharge urine Maintenance In order to get the best performance please follow the instructions below Put in a dry place and avoid the sunshine Avoid intense shaking and collisions Using wet cloths to remove dirt Avoid touching water clean it with a dry cloth in case Avoid dusty and unstable temperature environment Avoid washing the cuff 15 14...

Страница 9: ...me if measuring on the right arm Why do I get a different blood pressure at home compared to the hospital 1 Individual blood pressure varies multiple times everyday It is also affected by the way you tie your cuff and your measurement position so please take the measurement under the same conditions 2 If the person takes medicine the pressure will vary more 3 Wait at least 3 minutes for another me...

Страница 10: ... of 93 non condensing at a water vapour pressure up to 50hPa A01 PROBLEM SYMPTOM CHECK THIS REMEDY No power or Low batteries Error message Display will not light up Batteries are exhausted Replace with new batteries Insert the batteries correctly Batteries are inserted incorrectly E 01 shows E 02 shows E 03 shows Movement can affect the measurement Relax for a moment and then measure again E 04 sh...

Страница 11: ... for Safety Electromagnetic compatibility Performance requirements Clinical investigation EN ISO 15223 1 2016 ISO 15223 1 2016 Medical devices Symbols to be used with medical device labels labelling and information to be supplied Part 1 General requirements 21 20 Contact Information COMPLIED STANDARDS LIST FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the...

Страница 12: ...rvice life 2 Guidance and manufacturer s declaration electromagnetic emissions and Immunity Table 1 Guidance and manufacturer s declaration electromagnetic emissions RF emissions CISPR 11 Group 1 Class B Not applicable Compliance Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 RF emissions CISPR 11 Emissions test Not applicable Table 2 Guidance and manufacture...

Страница 13: ...000 4 8 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Conduced RF IEC61000 4 6 10 V m 80 MHz 2 7 GHz 80 AM at 1 kHz 10 V m 80 MHz 2 7 GHz 80 AM at 1 kHz Radiated RF IEC61000 4 3 Not applicable Not applicable Not applicable Not applicable Table 3 Guidance and manufacturer s declaration electromagnetic Immunity Test Frequency MHz 385 0 3 27 Radiat...

Отзывы: