60
10-2-12 Current sensor error/Input current sensor error
Indoor display
7-SEG DISPLAY
DESCRIPTION
C462
AC Input I_Limit Trip Error
Outdoor display
●
◎
●
Current sensor error
Input current sensor error
LED ON
LED BLINKING
LED OFF
1. Checklist :
1) Is the PFC Shunt(“A”) resistance value correct? Check the resistor is opened
2) Is the IPM Shunt(“B”) resistance value correct? Check the resistor is opened
3) Is there no short or open around “C”?
2. Troubleshooting procedure
NO
NO
YES
YES
Restart after power off.
Is the PFC shunt and IPM
shunt resistance value correct?
Is the current sensor error appeared again?
Exchange the Outdoor PBA
Exchange the Outdoor PBA
Terminate the service
Содержание AR09TXFYAWKNEU
Страница 40: ...40 7 2 OutdoorUnit AR09TXFYAWKXEU AR12TXFYAWKXEU AR09TXHZAWKXEU AR12TXHZAWKXEU CODE DB68 08682A 01 ...
Страница 43: ...43 8 3 DISPLAY PCB DB92 04833B ...
Страница 68: ...68 11 1 Indoorunit 11 Block Diagram ...
Страница 69: ...69 11 2 Outdoorunit ...