10-12
Samsung Electronics
10-2-11 Compressor starting error
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1
LED2
LED3
E461
Comp starting error
◎
{
◎
Outdoor display
{
◎
{
Comp starting error
O
LED ON
◎
LED BLINKING
{
LED OFF
1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart after power off.
Download the EEPROM data
Exchange the compressor
Is the restart error occurred again?
Is the connection of compressor wire is normal?
Is the restart error occurred again?
Is the compressor body and interphase
resistance insulated?
NO
NO
NO
NO
Terminate the service
Connect the comp wire normally
Terminate the service
Exchange the Outdoor PBA
YES
YES
YES
YES