28
English
Ener
gy
-Sa
ving F
eatur
es
good’sleep function
Use the good'sleep function to get a good sleep at night and to save
energy. You can select this function both in the Cool and Heat modes.
In the Cool or Heat mode
►
(Select
among On, Off,
and
.)
►
(Set the operation time.)
►
•
Press the
(Timer) button to change the current function
between On, Off, and
(good’sleep).
NOTE
• Once you start the good’sleep function, the Timer (
) indicator
appears on the indoor unit display.
• You can adjust the set temperature by 1 °C between 16 °C and 30 °C.
• The recommended and optimal set temperatures in the good’sleep
function are as follows:
Mode
Recommended set
temperature
Optimal set temperature
Cool
25 °C to 27 °C
26 °C
Heat
21 °C to 23 °C
22 °C
• The good’sleep function can be operated with the Wind-Free Cooling
function. Select the Wind-Free Cooling function to get mild breeze.
To select or cancel the Wind-Free Cooling function, press the
button.
• You can set the operation time to between 0.5 and 12 hours. Set the
operation time to 0.0 to cancel the good’sleep function.
• The default operation time for the good’sleep function in the Cool
mode is 8 hours. If the operation time is set to over 5 hours, the Wake
up function begins 1 hour before the set time. The air conditioner
stops automatically when the operation time expires.
•
When the Timed on, Timed off, and good'sleep functions are
overlapped, the air conditioner operates its timer with only the
function that you have started most recently.
• If you select the good'sleep function while such functions as 2-step
cooling, Fast, Comfort, Quiet, Single user function are running, these
functions are cancelled.