Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air
conditioner can be operated within. Refer to the table for efficient use.
Maintaining your air conditioner
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
If the outdoor temperature goes down to -5 °C, heating capacity may decrease as much as 60 %~70 % of specified
capacity according to the using conditions.
Mode
Indoor temperature
Outdoor temperature
Indoor humidity
Cooling
16 ˚C~
32
˚C
15 ˚C~43 ˚C
Relative humidity 80% or less
Heating
27 ˚C or less
-5 ˚C~24 ˚C
-
Dry
18 ˚C~32 ˚C
15 ˚C~43 ˚C
-
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
• If the heat pump is operating in Heat mode, defrost cycle is actuated to help remove frost from an outdoor unit that
may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the defrost cycle is completed.
Type
Description
Against cold air
The internal fan will be off to prevent cold air when the heat pump is heating.
Defrost cycle
The internal fan will be off to defrost ice when the heat pump is heating.
Vertical air flow blade will be closed during defrost cycle and it will open again during
heating operation after defrost cycle.
Protect compressor
The air conditioner does not start operating immediately to help protect the compressor
of the outdoor unit after it has been started.
Smart install
Through Smart install function, installer can check if the installation was done properly.
If the installation was not done properly, error indicator will turn on the indoor unit display.
Therefore user will know if the installation was done properly or not.