Содержание AQB09JJWC

Страница 1: ...SH Split type Air Conditioner Cooling and Heating ESPA OL FRAN AIS E S F DB98 25865A 2 USER S MANUAL AQB09JJWC AQB12JJWC AQB18J6WC AQB24J2WC Indoor Unit UQB09JJWC UQB12JJWC UQB18J6WC UQB24J2WC Outdoor...

Страница 2: ...oor unit If applicable WARNING DURING OPERATION Never store or load the air conditioner upside down or sideways to prevent the damage of the compressor Young children or infirm persons should be alway...

Страница 3: ...Function 14 Selecting the Energy Saving Function 15 Adjusting the Airflow Direction Vertically 16 Adjusting the Airflow Direction Horizontally 17 Setting the On Timer 18 Setting the Off Timer 19 Sett...

Страница 4: ...esign and shape can be changed according to the model Indoor Unit On Off button Air Inlet Temperature sensor Air flow blades outlet Turbo indicator RED Operation indicator GREEN Timer indicator GREEN...

Страница 5: ...H Air Inlet Rear Air Outlet Connection Valve Outdoor Unit Air Inlet Rear Air Outlet Connection Valve Air Inlet Rear Air Outlet Connection Valve Outdoor Unit Outdoor Unit UQB09JJWC UQB18J6WC UQB24J2WC...

Страница 6: ...er Set Cancel button Fan speed indicator Airflow direction On Timer indicator Off Timer indicator Turbo function indicator Sleep mode indicator Energy saving indicator Power On Off button Temperature...

Страница 7: ...1 2 Close the cover by sliding it back in its place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12...

Страница 8: ...ioner It will help you take full advantage of the unit s features You have already seen the basic description of the unit on pages from 4 to 6 Starting up with the next page you will find a series of...

Страница 9: ...re The air conditioner changes the Cool or Heat mode automatically depending on the current temperature during operation 2 You can change modes at any time If necessary press the button Result The ope...

Страница 10: ...n the Cool mode 2 You can change modes at any time N N N No o o ot t t te e e e Press the button to adjust the temperature until the required temperature is displayed You can set the temperature betwe...

Страница 11: ...es 5 F lower than the set temperature the air conditioner starts heating again 3 Press the button on the remote control until is displayed Result The indoor unit beeps each time you press the button T...

Страница 12: ...the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature is adjusted by 1 F The indoor unit beeps The air conditioner starts dehumidifying and the fan spee...

Страница 13: ...ou selected last The indoor unit beeps Press the button to select the fan speed until the required setting is displayed Low Medium High Result Each time you press the button the indoor unit beeps 3 To...

Страница 14: ...er is reset automatically to the previous setting You can select the Turbo function in the Auto Cool and Heat mode If you select this function in the Dry or Fan mode the mode changes to the Auto mode...

Страница 15: ...eeps The air conditioner runs in the Energy saving mode The outer airflow blade moves up and down To stop the Energy saving mode press the again 2 Press the button to adjust the temperature until the...

Страница 16: ...ically The outer airflow blade moves up and down to increase the efficiency of the cooling or heating operation N N N No o o ot t t te e e e If you turn the air conditioner Then the blade off is close...

Страница 17: ...tion Horizontally E 17 ENGLISH You can adjust the airflow direction horizontally with your hands The inner blades with small fins moves the air to the required direction Adjust the inner blades by mov...

Страница 18: ...aining time is displayed The timer indicator stops blinking The selected mode and the temperature on the display disappear after 10 seconds The air conditioner turns on automatically at the appointed...

Страница 19: ...n to complete the setting Result The remaining time is displayed The timer indicator stops blinking The air conditioner turns off automatically at the appointed time and the Off Timer setting disappea...

Страница 20: ...erature is decreased by 2 F every hour After the decrease of 4 F the temperature is maintained for 4 hours To Cancel the Sleep Timer Press the button to cancel the Sleep Timer Result The indoor unit b...

Страница 21: ...ns off after an hour automatically 1 Press the button until the desired mode is displayed at the remote control to select the mode after setting the 1 Hour Timer Result The air conditioner operates in...

Страница 22: ...nditioner is running at HEAT mode the outdoor unit s fan and compressor may stop at times This is normal simply wait until the air conditioner switches on again If a power failure occurs while the air...

Страница 23: ...cooling capacity may drop Low temperatures Water may leak and some malfunction may occur if the heat exchanger freezes High humidity levels Water may condense and drip from the surface of the indoor u...

Страница 24: ...oo low or too high Check if the air filter is dirty refer to page 25 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check if the required temperature is set cor...

Страница 25: ...wer right and left tabs of the grille 5 Clean the front grille with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals 6 If you have not used the air conditioner for a long...

Страница 26: ...inted in Korea ELECTRONICS If you have any comments or questions regarding Samsung products contact the SAMSUNG customer care center Samsung Electronics America Inc 1 800 SAMSUNG 7267864 www samsung c...