Temperature and Humidity Ranges
If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on
the operating condition.
If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop.
If you check the following tables, you can use your air conditioner more efficiently.
If the air conditioner is used at...
Then...
Heating capacity
The air conditioner may stop operating for the reason of protection.
Low temperatures
Water may leak and some malfunction may occur if the heat exchanger freezes.
Protection mechanism
Water may condense and drip from the surface of the indoor unit if you don’t use
the air conditioner for an extended period of time.
Operating Recommendations
Operation
Outdoor Temperature
Indoor Temperature
Indoor Humidity
09/12FC
09/12NSA
09/12NSB
18/24
Heating
-10°C to 24°C approx.
-15°C to 24°C approx.
27°C or less
-
Cooling
10°C to 43°C approx.
-10°C to 43°C approx.
16°C to 32°C approx.
80% or less
Dehumidifying
10°C to 43°C approx.
-10°C to 43°C approx.
16°C to 32°C approx.
-
Here are a few recommendations that you should follow when using your air conditioner.
Topic
Recommendation
Heating performances The heat pump function of the air conditioner absorbs heat from outside air and brings it
indoors. As the temperature of the outside air drops, the heating performance of air
conditioner will decrease. If you find that the room is not warm enough, using an additional
heating appliance is recommended.
Warm air circulation
The air conditioner circulates warm air to heat your room. It will take some time to warm the
air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on
in advance.
Frost
When outdoor temperature is low but humidity is high, frost may form on the outdoor unit at
Heat mode.
The heating operation stops.
The defrost mode will be triggered automatically for 3 to 14 minutes.
No intervention is required ; after about 7 minutes, the air conditioner operates again normally.
High indoor and
outdoor temperatures
If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT
mode, the outdoor unit’s fan and compressor may stop at times. This is normal;simply wait until
the air conditioner switches on again.
Power failure
If a power failure occurs while the air conditioner is operating, the unit will be switched off.
When the power returns, the air conditioner starts up again automatically.
Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal
operation starts up after 3 minutes for the reason of protection.
Cooling operation
The indoor unit may not get the selected fan speed such as Medium and Low under cooling
operation at very low outdoor temperatures for the protection of the indoor unit from ice
or frost.
During Low fan speed operation, cooling performance will be reduced. If the room does not be
cooled down when using Low fan speed operation, please adjust the indoor unit’s fan speed.
Silence Mode
When you operate Silence Mode in cooling and heating, fan speed will decrease to make noise
quieter.
As a result, the performance of the unit may be reduced.