Samsung Electronics
24
Troubleshooting procedures
1
• Check the items to check first time.
2
• Check the self-diagnostic mode and action method.
3
• Check in detail the troubled parts according to the sequence of "trouble shooting by the phenomena".
1.
Is proper the power voltage?
The power voltage shall be of 198V-264V 50Hz.
2.
Is the cable connected correctly between the indoor and outdoor unit?
The indoor and outdoor units shall be connected with 8 wires including the grounding.
Check whether the wires of indoor and outdoor units are connected with the correct wire no. and terminal board no.
3.
The phenomena in the following table is not related to the fault of air conditioner.
- Heating operation
The compressor does not operated even though the set
temperature is set higher than the indoor temperature.
- Cooling operation
The compressor does not operated even though the set
temperature is set lower than the indoor temperature.
- Fan speed is not adjusted during the auto, dry, turbo and
long operation.
- The temperature is not adjusted during the auto, dry, turbo
and long and fan operation.
- The compressor repeats the stop and start with the inter-
val of several minutes during dry.
- During the heating operation, the lamp on "deice" is on at
the control panel and the compressor operates.
- During the heating, the outdoor unit fan motor repeats
start/stop or even the compressor repeats the start and
stop.
- During the heating, the compressor and outdoor unit fan
motor operate but indoor unit fan motor does not operate.
1
2
3
4
5
6
7
Phenomena
Description
- The operation of compressor is delayed for 3 minutes for
the protection of compressor when it is off and on again.
- The compressor operates normally after 3 minutes even the
lnitial power is on.
- The fan speed is automatically adjusted during the auto,
dry, turbo and long operation.
- The set temperature is automatically set during the auto,
dry and long operation.
- The wind blow operation is the mode to circulate the indoor
air.
- At the dry operation, the set temperature and the indoor
temperature are compared to adjust the compressor
start/stop time in order to dehumidify.
- The deice operation is being performed in order to melt the
frost by outdoor unit and its maximum time is 9 minutes.
- It is the function to prevent the overheating of the indoor
evaporator, where the temperature of indoor unit heat
exchanger reaches 52°C, the normal operation is done.
- This is the function to prevent the cooling air incoming to
the indoor, where the temperature of indoor evaporator
reaches 27°C, the indoor fan motor operates.
No
5. Troubleshooting
5-1 The Items to be checked first time
Содержание APH289SEF
Страница 38: ...MEMO 37 Samsung Electronics ...
Страница 47: ...Samsung Electronics 46 6 5 4 3 11 16 15 2 15 4 18 8 2 14 12 15 1 15 15 3 17 1 7 13 9 10 6 2 Outdoor Unit ...
Страница 50: ...49 Samsung Electronics 8 PCB Diagram 8 1 ASS Y MAIN PCB DB93 02594D TOP BOTTOM ...
Страница 53: ...Samsung Electronics 52 8 2 ASS Y PANEL PCB DB93 01419F TOP BOTTOM ...
Страница 58: ...57 Samsung Electronics 10 2 PANEL PCB This Document can not be used without Samsung s authorization ...
Страница 59: ...MEMO Samsung Electronics 58 ...
Страница 60: ...MEMO 59 Samsung Electronics ...
Страница 61: ...MEMO Samsung Electronics 60 ...