3)   Assemble the product by adjusting it 

with the direction, following the direction 
carved on the surface of Cushion Mid.  Put 
the part written with “Down

” downwards 

and put the part with “Motor

” towards 

the Motor when assembling the unit. 

 

 

  

  Make sure not to break down EPS      

structure. 

Содержание AN026JSKLKN Series

Страница 1: ...5JSKLKN EU AN050JSKLKN EU AN080JSKLKN EU AN100JSKLKN EU ERV Energy Recovery Ventilator CONTENTS 1 Precautions 2 Product Specifications 3 Alignment and Adjustments 4 Disassembly and Reassembly 5 Wiring Diagram 6 Circuit Descriptions 7 PCB Diagram 8 Operating Instructions 9 Troubleshooting 10 Reference Sheet AN026JSKLKN AN035JSKLKN AN050JSKLKN AN080JSKLKN AN100JSKLKN ...

Страница 2: ...thod 3 1 3 2 Option Switch Key Function Address 3 2 4 Disassembly and Reassembly 4 1 4 1 AN026JSKLKN 4 2 4 2 AN035JSKLKN AN050JSKLKN AN080JSKLKN AN100JSKLKN 4 16 5 Wiring Diagram 5 1 6 Circuit Descriptions 6 1 6 1 PCB Circuit Descriptions 6 1 7 PCB Diagram 7 1 8 Operating Instructions 8 1 8 1 Name of Each Part 8 1 8 2 Using installation service mode of ERV wired remote controller 8 5 9 Troubleshoo...

Страница 3: ...nics Contents 10 Reference Sheet 10 1 10 1 Ventilator Operation Priniple 10 1 10 2 Index for Model Name 10 2 10 3 Cleaning the Dust Filter 10 3 10 4 Cleaning the Heat Exchange Element 10 5 10 5 Q A for Non trouble 10 7 ...

Страница 4: ...it on your own Make sure that these installations are carried out by qualified personnel to avoid electric shock or fire O Perform the installation securely referring to the installation manual Incomplete installation could cause personal injury due to fire electric shock or the unit falling O Do not install the product in a place where it is or might be exposed to inflammable gas leakage When the...

Страница 5: ...sion O Make sure to keep winds from the product away from a burner It may cause incomplete combustion O Do not utilize the ventilator to preserve machinery foods animals plants or cosmetic products It may cause damage to the machinery foods animals plants or cosmetic products O Do not spray insecticide or other inflammable materials on the product It may cause unit falling or fire O Make sure to k...

Страница 6: ...eatment If not it may cause electric shock or injury O Do not utilize steel scrubber or chemicals such as benzene or thinner It may cause discoloration or unit falling O Do not expose animals or plants to the winds from the unit for a long period of time It may damage animals or plants O Do not put hands or sticks into the air suction duct or air outlet of the product It may cause injury as ventil...

Страница 7: ...usted when indoor heating and cooling By Pass Mode The ventilation method is used when temperature gap of indoor and outdoor is not big Outdoor air flows into indoor Q High Sensibility Sensor Option An optimal air condition is maintained through Carbon Dioxide CO2 sensor and temperature sensor Q Humidity Control Fresh air conditions are guaranteed by recovering moisture in winter while exhausting ...

Страница 8: ...ling Indoor 24 C DB 17 C WB Outdoor 35 C DB 24 C WB Heating Indoor 22 C DB 13 9 C WB Outdoor 2 C DB 0 44 C WB Q AN026JSKLKN Power Source 220 240 V 50 60 Hz Ventilation Mode Heat Ex Ventilation By Pass Ventilation The Level of the Air Volume Turbo High Low Turbo High Low Power Supply W 115 80 50 115 80 50 Air Volume m h 350 350 260 350 350 260 External Static Pressure Pa 155 100 85 155 100 85 Tempe...

Страница 9: ...es Cooling Indoor 24 C DB 17 C WB Outdoor 35 C DB 24 C WB Heating Indoor 22 C DB 13 9 C WB Outdoor 2 C DB 0 44 C WB Q AN050JSKLKN Power Source 220 240 V 50 60 Hz Ventilation Mode Heat Ex Ventilation By Pass Ventilation The Level of the Air Volume Turbo High Low Turbo High Low Power Supply W 330 230 125 330 230 125 Air Volume m h 800 800 560 800 800 560 External Static Pressure Pa 155 90 80 155 90 ...

Страница 10: ...ture Exchange Efficiency Cooling 70 70 74 Heating 70 70 74 Enthalpy Exchange Efficiency Cooling 50 50 55 Heating 70 70 76 Size widthxheightxdepth mm 1220 340 1135 Weight kg 67 Duct Size mm 250 Trial Operation Conditions 1 Air Volume External Static Pressure Comply with KS Heat Exhaust Ventilation System Standards KS B6879 2 Heat Exchange Temperature Exchange Efficiency Comply with regulations to p...

Страница 11: ... DEIVICE OPTION KIT DB97 09494B 1 Separate Sale Ŷ MSD EAN1 Assy SPI Device Option Kit Item Descriptions Code No Q TY Remark ASS Y ERV REMOCON DB93 14406C 1 Separate Sale Ŷ MWR VH12N Wired Remote Controller 2 3 2 Filter Specifications Item Descriptions Code No Remark Duts Filter DB63 01665A AN026JSKLKN Basic Cleaning Impossibility of Water Washing DB63 01665F AN035JSKLKN AN050JSKLKN DB63 01665G AN0...

Страница 12: ...ess of error E198 Thermal fuse open error in power ther minal block Check wire connection conditions of CN140 connector Check conditions of wire connected power terminal block occurrence of error at open E202 System down caused by communica tion error Check disconnection of communication wire E221 Outdoor temperature sensor error SHORT OPEN Check connector disconnection of CN41 and connection cond...

Страница 13: ...3 2 Samsung Electronics 3 2 Option Switch Key Function Address م If you use a existing EEPROM after replace MAIN PBA don t need to reset option SUB EEPROM PBA ...

Страница 14: ...peration condition Heat exchange Turbo wind Ɣ Repeat on off of trial operation whenever a key enters Ɣ Trial operation is stopped 30 minutes later it returns to DISPLAY Default state 30 minutes later 2 KEY 2 Data display Ɣ The marked contents is changed whenever you press KEY2 once Ɣ Press the KEY2 switch for more than 3 seconds to reset Function InputTime KEY1 KEY2 1time TrialOperationofHeatExcha...

Страница 15: ...c e d SEG4 Q Numbers and Alphabets on PCB Display Press times Indication Example Display SEG1 SEG2 SEG3 SEG4 1 Exhaust Air FAN RPM 1 350RPM 1 1 3 5 2 Supply Air FAN RPM 950RPM 2 Turn Off 9 5 3 Indoor Temperature 25 C 3 Turn Off 2 5 4 Outdoor Temperature 30 C 4 Turn Off 3 0 5 CO2 Density 1 220ppm 5 1 2 2 6 Installed Unit Number 3 unit 6 Turn Off Turn Off 3 ...

Страница 16: ...Samsung Electronics 4 1 4 Disassembly and Reassembly Q Necessary Tools Item Remark SCREW DRIVER MONKEY SPANNER ...

Страница 17: ...ve the unit from ceiling suspension Disassembly is not required when Fan Motor Element Filter replacement or cleaning 2 Ass y Cabi Cover Element 1 Remove the 3 bolts on Cover Element to detach it Use Screw Driver 2 Loosen the clips connected to the Cover 3 Separate the connector connected to the Damper by pulling out the connector body Q Disassembly before Installation ...

Страница 18: ...B 1 Remove the 4 bolts and separate Bracket Body Element B Use Screw Driver 4 Ass y Element 1 Pull up the 2 strings hanging out from the 2 ends of Element to detach the Element 5 Bracket Body Element A 1 Remove the 4 bolts and separate Bracket Body Element A Use Screw Driver ...

Страница 19: ...ocedure Remark 6 Cushion Bypass 1 Slide Cushion Bypass to the direction seen in the picture besides Take caution not to break down EPS structure 2 Find Wire connected to the temperature sensor Separate the 2 temperature sensor connectors ...

Страница 20: ... 5 No Parts Procedure Remark 7 Cabi Cover 1 Detach Cabi Cover by removing 9 bolts Use Screw Driver 8 Cushion Mid 1 Slide Cushion Mid to the direction seen in the picture besides Take caution not to break down EPS structure ...

Страница 21: ...g the motor wire by twisting them slightly 3 Rotate bolts fixing the Bracket 5 turns Use Screw Driver Supply air and exhaust air of the products have 4 bolts each The bolts are not required to be removed 4 Detach the whole Ass y Blower Motor which is made up of Fan Motor Bracket Motor and Cover Bell Mouse 5 2 Motors are placed within the unit for input and outlet ...

Страница 22: ...Procedure Remark 10 Ass y Blower 1 Unscrew the nuts fixing Fan by rotating them right Use Monkey Spanner Do not touch the Fan Its sharp edge may cause injury 2 Detach the Motor with removing the 4 bolts fixing Bracket Use Screw Driver ...

Страница 23: ...Electronics No Parts Procedure Remark 11 Ass y Case Blower 1 Remove the 2 bolts attached at the sides of the body Use Screw Driver 2 Remove the 4 bolts on the other side of Cabi Cover to detach it Use Screw Driver ...

Страница 24: ...Samsung Electronics 4 9 No Parts Procedure Remark 3 Detach the Ass y Case Blower 4 Unscrew the Bracket Case Blower and the Case Blower Use Screw Driver ...

Страница 25: ...4 10 Samsung Electronics No Parts Procedure Remark 12 Ass y Damper Ass y Lever Bypass 1 Remove all bolts to separate Bracket and Cam Use Screw Driver ...

Страница 26: ...m ceiling suspension Disassembly is not required when Fan Motor Element Filter replacement or cleaning 2 Ass y Cabi Cover Element 1 Remove the 3 bolts on Cover Element to detach it Use Screw Driver 2 Loosen the clips connected to the Cover 3 Separate the connector connected to the Damper by pulling out the connector body Q Product Disassembly while still being installed ...

Страница 27: ...4 12 Samsung Electronics No Parts Procedure Remark ...

Страница 28: ...ronics 4 13 No Parts Procedure Remark 3 Ass y Element 1 Remove the 4 bolts and separate Bracket Body Element B Use Screw Driver 2 Pull down the 2 strings hanging out from the 2 ends of Element to detach the Element ...

Страница 29: ...lement A Use Screw Driver 5 Cushion Bypass 1 Slide Cushion Bypass to the direction seen in the picture besides Take caution not to break down EPS structure 6 Cushion Mid 1 Slide Cushion Mid to the direction seen in the picture besides 2 Separate the 2 temperature sensor connectors Take caution not to break down EPS structure ...

Страница 30: ... by twisting them slightly 3 Rotate bolts fixing the Bracket 5 turns Use Screw Driver Supply air and exhaust air of the products have 4 bolts each The bolts are not required to be removed 4 Detach the whole Ass y Blower Motor which is made up of Fan Motor Bracket Motor and Cover Bell Mouse 5 2 Motors are placed within the unit for input and outlet ...

Страница 31: ...unit from ceiling suspension Disassembly is not required when Fan Motor Element Filter replacement or cleaning 2 Cover Element 1 Remove the 2 bolts of the Cover Element Use Screw Driver 2 Find the Element and 2 Dust Filters 3 Ass y Element Ass y Filter 1 Detach Element and Filter from the unit Make sure detach the Filter before the Element 2 There are 2 Element within the product Q Disassembly bef...

Страница 32: ... Wire 5 Guide Element 1 Separate the guides fixing Element Use Screw Driver 1 Guide is located at each left and right end of the product Each guide is attached to the product with 1 bolt 6 Thermistor Ass y Wire 1 Separate the Temperature Sensor from the fixed part The Temperature Sensor is attached with wire clips 2 The input and output channel has 1 Temperature Sensor each ...

Страница 33: ... the holder fixing the motor wire by twisting it slightly 3 2 Motors are placed within the product for supply air and exhaust air 8 Cushion Mid 1 Slide the EPS structure to the side and detach it as seen in the picture besides 2 Slide and pull the EPS structure to separate it as seen in the picture besides ...

Страница 34: ... the product by adjusting it with the direction following the direction carved on the surface of Cushion Mid Put the part written with Down downwards and put the part with Motor towards the Motor when assembling the unit Make sure not to break down EPS structure ...

Страница 35: ...Parts Procedure Remark 9 Connector Damper Cam 1 Separate the Damper from the unit Use Screw Driver 2 Separate the connectors by holding their bodies and pulling them out 3 Unscrew bolts attached to Bracket and Cam Use Screw Driver ...

Страница 36: ...s Input and outlet of the products have 2 bolts each Use Screw Driver The bolts are not required to be removed 11 Blower Motor Fan 1 Unscrew the nuts fixing the Fan by rotating them left Use Monkey Spanner 2 Unscrew the bolts fixing Motor to detach if from the Motor Bracket It has 4 bolts Use Screw Driver Do not touch the Fan Its sharp edge may cause injury ...

Страница 37: ...ket from Case Blower Use Screw Driver There are 5 bolts 2 Separate the Case Blower by sliding the Case Blower upwards 13 Cushion Blower EA Cushion Blower SA 1 Detach the EPS structure fixed to Case Blower by sliding the structure to the side Make sure not to break down the EPS structure ...

Страница 38: ...ssembly is not required when Fan Motor Element Filter replacement or cleaning 2 Cover Element 1 Remove the 2 bolts of the Cover Element Use Screw Driver 2 Find the Element and 2 Dust Filters 3 Ass y Element Ass y Filter 1 Detach Element and Filter from the unit Make sure detach the Filter before the Element 2 There are 2 Element within the product All the procedure has to be verified because the c...

Страница 39: ... Screw Driver 1 Guide is located at each left and right end of the product Each guide is attached to the product with 1 bolt 5 Ass y Fan Parts 1 Separate motor connectors 2 Loosen the holder fixing the motor wire by twisting it slightly 3 2 Motors are placed within the product for supply air and exhaust air ...

Страница 40: ...haust air and supply air 2 Pull out the EPS structure through the inspection hole 3 Assemble the product by adjusting it with the direction following the direction carved on the surface of Cushion Mid Put the part written with Down downwards and put the part with Motor towards the Motor when assembling the unit Make sure not to break down EPS structure ...

Страница 41: ...Parts Procedure Remark 7 Connector Damper Cam 1 Separate the Damper from the unit Use Screw Driver 2 Separate the connectors by holding their bodies and pulling them out 3 Unscrew bolts attached to Bracket and Cam Use Screw Driver ...

Страница 42: ...cket 10 turns Input and outlet of the products have 2 bolts each Use Screw Driver The bolts are not required to be removed 9 Ass y Bracket Motor 1 Detach the whole Ass y Blower Motor which is made up of Fan Motor Bracket Motor and Cover Bell Mouse through the inspection hole 2 2 Motors are placed within the unit for supply air and exhaust air ...

Страница 43: ...rk 10 Blower Motor Fan 1 Unscrew the nuts fixing the Fan by rotating them left Use Monkey Spanner 2 Unscrew the bolts fixing otor to detach if from the Motor Bracket It has 4 bolts Use Screw Driver Do not touch the Fan Its sharp edge may cause injury ...

Страница 44: ...msung Electronics 5 1 5 Wiring Diagram Q AN026JSKLKN AN035JSKLKN AN050JSKLKN AN080JSKLKN AN100JSKLKN This Document can not be used without Samsung s authorization OPTION OPTION OPTION OPTION OPTION OPTION ...

Страница 45: ...g Electronics Samsung Electronics 6 2 6 Circuit Descriptions 6 1 PCB Circuit Descriptions This Document can not be used without Samsung s authorization SMPS Circuit Part Motor Load Circuit Part Comm Circuit Part ...

Страница 46: ...7 4 The voltage of secondary side is decided by TURN numbers of TRANS winding DC 15V is utilized only for CONTROL power source of BLDC MOTOR while DC12V is used for power source of CO2 sensor 5 When BLDC MOTOR faulty takes place DC 15V or DC 12V might not be generated 6 SWITCHING DIODE of secondary side should not utilize usual rectification DIODE because SWITCHING speed of SMPS reaches 130kHz Hig...

Страница 47: ...rmined by DC0V DC6V voltage 4 No 6 PIN of CN73 is the RPM FEEDBACK POINT which delivers MOTOR rotation to MICOM If DC15V continues to be found when measuring DC15V and No 6 PIN FAN MOTOR ERROR occurs because FEEDBACK is not conducted 5 CONNECTOR of CN73 is dislocated when PCB power source is authorized DC310V voltage may flow into CONTROL IC within BLDC in a moment damaging CONTROL IC of BLDC It m...

Страница 48: ...n case of fault power source link or communication link 2 SNUBBER Circulation NOISE of over 5V is eliminated through SAC5 0 DIODE 3 485 IC Line Driver Reeceiver HIGH LOW is determined through voltage gap between the two electrodes of A and B A B 200mV HIGH B A 200mV LOW DATA is received and prepared with R PORT When sending the DATA HIGH is input at ENABLE 4 EXCLUSIVE GATE Non polar communication ...

Страница 49: ...Samsung Electronics 7 1 7 PCB Diagram 5 6 7 8 9 10 11 17 16 4 3 1 12 13 18 14 15 20 19 2 This Document can not be used without Samsung s authorization ...

Страница 50: ...7 2 Samsung Electronics 5 6 7 8 9 10 11 17 16 4 3 1 12 13 18 14 15 20 19 2 This Document can not be used without Samsung s authorization ...

Страница 51: ...it connector CN801 YEL Communication connection part F1 F2 Communication between ventilation systems communicate with interface module V1 V2 Power supply connector for interface module F3 F4 Wired remote controller communication TB_COMM BLK Thermal Fuse status input connector Inputs status of Thermal Fuse within the power terminal block CN140 WHT Internal damper power supply Damper motor control p...

Страница 52: ...R It refers to separation shed to switch from heat exchange mode to Usual Ventilation mode or vice versa Q Dust Filter Dust filter protects heat exchange element and filter supplied air Q Electric Component Box It is made up of circulation of the unit Q Duct Connection Flange It refers to the pipe connected to the duct for supply air outdoor air indoor air and exhaust air Outdoor Air Maintenance c...

Страница 53: ... DAMPER It refers to separation shed to switch from heat exchange mode to Usual Ventilation mode or vice versa Q Dust Filter Dust filter protects heat exchange element and filter supplied air Q Electric Component Box It is made up of circulation of the unit Q Duct Connection Flange It refers to the pipe connected to the duct for supply air outdoor air indoor air and exhaust air Outdoor Air Supply ...

Страница 54: ...lassification Indication Function Displays operation mode Displays set time Displays Away mode Displays fan speed Displays SPI Optional Displays CO2 sensor Optional Displays inspection invalid and lock Displays range hood central control and external interlock ...

Страница 55: ...he mode you want to operate Schedule button Sets the timer function Set Cancel button Completes the timer function Cancels the timer function Press the button for more than 3 seconds Fan speed button Adjusts the fan speed Away Filter reset button Selects the Away mode the button for more than 3 seconds Time control button ...

Страница 56: ...the desired menu ඖ Using the buttons select a main menu number and press the Away button to enter the sub menu setting screen ඖ Using the buttons select a sub menu number and press the Away button to enter data setting screen ඖ When you enter the setting stage the current setting is displayed ඖ Refer to the chart for data settings ඖ Using the buttons select the settings and press the Away button t...

Страница 57: ...s 0 1 0 16 EA 2 Checking the number of connected ERVs 0 1 0 16 EA 3 Checking the Micom code of ERV wired remote controller none 3 Micom code 4 Checking the program version information of ERV wired remote controller none 3 2 1 Setting address option 2 Target ERV View Master 3 Address of registerd devices hexadecimal 5 2 Setting checking main address Main address of target 1 Main address 00H 4FH hex...

Страница 58: ...hecking ERV View Master ERV View Master 3 Address of registered devices hexadecimal 5 4 1 Setting checking optional functions of ERV wired remote controller ERV wired remote controller Master Slave 0 1 0 Master 1 Slave 2 Use of external interlock 0 1 0 Disuse 1 Use 5 1 Setting checking ERV Exhaust RPM none 2 0 9999 2 Intake RPM none 2 0 9999 3 Indoor temperature none 1 0 99 4 Outdoor temperature n...

Страница 59: ...SEG8 SEG12 On Heat EX By Pass Auto Quiet Away SEG14 SEG18 SEG20 24 By Pass Auto Quiet Away p SEG 2 3 PAGE 1 PAGE 6 PAGE 2 PAGE 7 PAGE 3 PAGE 8 PAGE 4 PAGE 9 PAGE 5 PAGE 10 SEG 14 15 SEG 4 5 SEG 16 17 SEG 6 8 SEG 18 20 SEG 9 10 SEG 21 22 SEG 11 12 SEG 23 24 p p p p p p p p Caution 2 When setting the address or option you can set the target device with sub menu no 1 3 Power Master Reset is a setting...

Страница 60: ...6 20 32 30 48 40 64 01 1 11 17 21 33 31 49 41 65 02 2 12 18 22 34 32 50 42 66 03 3 13 19 23 35 33 51 43 67 04 4 14 20 24 36 34 52 44 68 05 5 15 21 25 37 35 53 45 69 06 6 16 22 26 38 36 54 46 70 07 7 17 23 27 39 37 55 47 71 08 8 18 24 28 40 38 56 48 72 09 9 19 25 29 41 39 57 49 73 0A 10 1A 26 2A 42 3A 58 4A 74 0B 11 1B 27 2B 43 3B 59 4B 75 0C 12 1C 28 2C 44 3C 60 4C 76 0D 13 1D 29 2D 45 3D 61 4D 77...

Страница 61: ...t no 5 2 Press the Away button to select the number you will set on the sub menu Press the or button to select no 1 3 Press the Away button to enter the data setting stage When you enter the setting stage the current setting is displayed 4 Press the or button to select no 1 The status of external interlock changes from Disuse to Use 5 Press the Set button to complete the option settings Save the s...

Страница 62: ... MOTOR operation restarts Trouble Cause Solution Remark If the product is not turned on Check electric power content and wire Fix power supply Check FUSE disconnection Replace FUSE A FUSE is provided in PBA If the remote control is not working Check remote control connection Connect or replace connection wire of remote control If supply air fan or exhaust air fan are not working Check fan motor Ch...

Страница 63: ...Indoor option setting error 6 E198 Thermal fuse open error in power therminal block 7 E202 System down caused by communication error 8 E221 Outdoor temperature sensor error SHORT OPEN 9 E490 Prohibition of operation under outside indoor temperature 0 10 E561 Supply air SA fan motor error 11 E562 Exhaust air EA fan motor error 12 E654 Inside damper error 9 3 Errors and Solutions 6 602 609 indicate ...

Страница 64: ...de appears when unit operation starts or while it is in operation Is temperature sensor connector CN41 of PCB dislocated from PCB Yes Detach the temperature sensor connector from PCB to measure resistance between the two electrodes Restart the unit after having replaced PCB Is measured resistance a lot different from the value specified by the table besides Restart operation after link the connect...

Страница 65: ...is in operation No Is CO2 sensor connector CN43 of PCB dislocated from PCB Assembly the connector Yes No Is sensor connector CN101 dislocated from the sensor Does LED1 of CO2 sensor flicker once in 6 seconds Is DC12V power measured from sensor connector Is square wave measured from sensor connector PCB check or replacement Sensor check or replacement No No No t 02 sensor checks DATA once in six se...

Страница 66: ... outputs square wave 9 4 3 Supply Air Fan Error Check product operation No Is Motor connector CN74 of PCB dislocated from PCB Assembly connector Yes No Does Motor rotate in case of operation Is DC0V DC6V power measured from Motor PCB check or replacement Is Motor RPM is lower than 120 Yes E561 code appears when unit operation starts or while it is in operation No Motor check or replacement Yes ...

Страница 67: ... outputs square wave 9 4 4 Exhaust Air Fan Error Check product operation No Is Motor connector CN73 of PCB dislocated from PCB Assembly connector Yes No Does Motor rotate in case of operation Is DC0V DC6V power measured from Motor PCB check or replacement Is Motor RPM is lower than 120 Yes E562 code appears when unit operation starts or while it is in operation No Motor check or replacement Yes ...

Страница 68: ...ll from any Slave Check the communication line of MASTER PCB and connector then replace the PCB No E202 code appears when unit operation starts or while it is in operation Check display with pressing RESET KEY K3 of MASTER PCB in order to CHECK number of Slaves responding to Tracking After eliminate communication line connecting Master and Slave check the 2 lines of Masterwith Scope Reconnect comm...

Страница 69: ...ime of tracking is indicated Is voltage of the 2 lines square wave of over DC 0 7V as seen in the picture below No E601 code appears when unit operation starts or while it is in operation Start retracking with pressing both Wind Strength Control Button and Operation Selection Button of Wired Remote Control simultaneously for 5 seconds Eliminate communication line between Wired Cemote Control and V...

Страница 70: ...and Micom Cause Fault of EEPROM Sensor SPEC 9 4 7 EEPROM Error EEPROM Reassembly Remove short or unsoldering Replace EEPROM PBA No No Yes Yes Is EEPROM SUB PBA reassembled correctly Is any problem such as short or unsoldering between EEPROM PIN Turn on the unit Occurrence of E162 EEPROM PBA CODE DB93 12483A ...

Страница 71: ...ck or replacement No No Yes Yes Check operation Assembly the connector Yes No Check operation No Is DAMPER Motor connector of PCB CN72 dislocated from PCB Assembly the connector Yes Is DAMPER switch working PCB check or replacement E654 code appears when unit operation starts or while it is in operation No Is DAMPER switch connector of PCB CN51 dislocated from PCB Is AC220 240V power measured from...

Страница 72: ...Cause Check the connection of terminal block Temperature rise by screw loosening Sensor SPEC 9 4 9 Thermal Fuse Open Error in Power Therminal Block No No Is the CN140 Connector of PCB correctly connected to wire Restart after connecting connector Yes Is the ends of the connector shorted Occurring E198 Check both ends of the connector connected terminal block Replace MAIN PBA No ...

Страница 73: ...0 3 0 2 0 0 7 AN100JSKLKN 0 1 0 3 4 0 1 1 6 4 4 3 2 1 5 4 4 0 3 0 2 0 0 8 Error Mode Option setting error Display E163 Check Method Entering incorrect ERV option or entering no ERV option at all Cause Entering incorrect ERV option or entering no ERV option at all Sensor SPEC 9 4 10 Option Setting Error ఐ Progress re input after reconfirming option by model attached below If you use a existing EEPR...

Страница 74: ...t exchange element working properly Clean or replace the filter if it contains too much dust No Are outdoor air input and indoor output in good conditions 9 4 12 When indoor air smells bad or contains dust Clean or replace the heat exchange element if it is damaged No Yes Is heat exchange element working properly Yes Yes Indoor air smells bad or contains dust Clean or replace the filter if it is d...

Страница 75: ...ion switch No Is the unit set to Heat EX mode in case of heating Install the hood properly Replace it if it is damaged No If there is no or fault insulation do the insulation job No Is outside hood installed properly Is insulation of body and duct done properly 9 4 14 When cold air is infused Control DAMPER Change to Heat EX mode No Yes DAMPER Heat EX mode Yes Is the unit infusing cold air Check h...

Страница 76: ...g excessive noise Install Heat Exchange Element and filter properly Is there any substance inside the Duct Are Heat Exchange Element well cleaned No Eliminate Dust or other substance No Eliminate the substance No Measure RPM and fix it No Is Fan Motor working properly Replace or repair PCB Are Heat Exchange Element and Filter installed properly ...

Страница 77: ... outdoor air At this section only technological explanation is provided Q Process The ventilator supplies outdoor air and exhaust indoor air Q Air Volume The volume is determined according to volume of supply air or exhaust air It is indicated with CMH Cubic Meter per Hour 10 1 2 Additional Function Q The unit supports Heat EX mode and By Pass mode selected by DAMPER Q Heat EX mode Temperature and...

Страница 78: ...L HIGH VTL FILTER E NORMAL HIGH VTL F NORMAL STANDARD G MOLD HIGH VTL FILTER H MOLD HIGH VTL J MOLD STANDARD K COMMERICIAL HIGH VTL FILTER L COMMERICIAL HIGH VTL M COMMERICIAL STANDARD T MINI HIGH VTL V ERV with DX coil RatingVoltage A A 115V 60hz 1Ф B B 220V 60Hz 1Ф C C 208 230V 60Hz D D 200 220V 50Hz E E 220 240V 50Hz F F 208 230V 60Hz 3Ф G G 380 415V 50Hz 3Ф H H 380V 60Hz 3Ф J J 460V 60Hz 3Ф K ...

Страница 79: ...th a vacuum cleaner or a brush 5 Reassemble the dust filters and the maintenance cover O Make sure to insert the dust filters correctly If not dust may accumulate on the heat exchange element and decrease the efficiency t IBOHF UIF EVTU GJMUFST JO FWFSZ UXP ZFBST PXFWFS UIF QFSJPE PG GJMUFS replacement may vary according to the used period and condition t G UIF EVTU GJMUFS JT EBNBHFE QVSDIBTF JU J...

Страница 80: ... with a vacuum cleaner or a brush 5 Reassemble the dust filters and the maintenance cover O Make sure to insert the dust filters correctly If not dust may accumulate on the heat exchange element and decrease the efficiency t IBOHF UIF EVTU GJMUFST JO FWFSZ UXP ZFBST PXFWFS UIF QFSJPE PG GJMUFS replacement may vary according to the used period and condition t G UIF EVTU GJMUFS JT EBNBHFE QVSDIBTF J...

Страница 81: ...l dust and particles on the heat exchange element with a nozzle of a vacuum cleaner O Take care not to attach the nozzle too close It may damage the heat exchange element 5 Reassemble the heat exchange element and the maintenance cover t Do not wash the heat exchange element It may decrease its efficiency t G UIF IFBU FYDIBOHF FMFNFOU JT EBNBHFE QVSDIBTF JU JOEJWJEVBMMZ in a service center or an a...

Страница 82: ... sure clean them at once 4 Remove all dust and particles on the heat exchange elements with a nozzle of a vacuum cleaner O Take care not to attach the nozzle too close It may damage the heat exchange element 5 Reassemble the heat exchange elements and maintenance cover t Do not wash the heat exchange element It may decrease its efficiency t G UIF IFBU FYDIBOHF FMFNFOU JT EBNBHFE QVSDIBTF JU JOEJWJ...

Страница 83: ... within buildings except places with ventilation system such as bathrooms or kitchens with hood Q How the functions can be exchanged A The unit supports manual and automatic operation which includes four function modes according to air volume Heat EX required in summer and winter and usual ventilation optional in spring and fall are available Others Q What is the function and composition of filter...

Страница 84: ...able International and or domestic law Samsung Electronics Co Ltd April 2015 Printed in Korea Code No AC AC 00113E_1 GSPN GLOBAL SERVICE PARTNER NETWORK Area Web Site Europe CIS Mideast Africa gspn1 samsungcsportal com Asia gspn2 samsungcsportal com North Latin America gspn3 samsungcsportal com China china samsungportal com ...

Отзывы: