E-
42
I
NSTALLING THE
O
UTDOOR
U
NIT
Auxiliary Circuit Breaker
Electrical Work
1
The supply voltage must be the same as the rated voltage of the
air conditioner.
2
Prepare the power souce for exclusive use with the air conditioner.
3
Use 20 amperes time delay fuse or circuit breaker.
➢
When using the special NFB, use the NFB to bear the capacity of the
air conditioner.
➢
Otherwise, the shot circuit in the NFB may occur.
Outdoor unit
Distribution
board
Auxiliary
power s/w
◆
Auxiliary circuit breaker should be installed near outdoor unit so
that each access is possible. Main/outdoor power supply cable are
connected to upper/lower terminal of auxiliary circuit breaker.
◆
It is necessary that the conduit kit for power supply to the outdoor
unit be installed between auxiliary power S/W and the outdoor
unit. (the conduit kit is optional)
❊
The designs and shape are subject to
change according to the model.
MODEL
AM26B1C13
AM27B1C07
AM27B1C13
Power supply
Power cable
Assembly cable
Operating current
Starting Current
Power consumption
208-230V~/60Hz
AM18B1C09
3G AWG 14
4G AWG 16
11.6A
2580W
31A
31A
11.4A
22A
8.4A
2550W
1920W
Содержание AM18B1C09
Страница 26: ...E 26 INSTALLATION MANUAL...