Carefully follow the precautions listed below because they are 

essential to guarantee the safety of the equipment.

  WARNING

 • Always disconnect the air conditioner from the power 

supply before servicing it or accessing its internal 

components.

 • Verify that installation and testing operations are 

performed by qualified personnel.

 • Verify that the air conditioner is not installed in an 

easily accessible area. 

General information

 • Carefully read the content of this manual before 

installing the air conditioner and store the manual in a 

safe place in order to be able to use it as reference after 

installation. 

 • For maximum safety, installers should always carefully 

read the following warnings. 

 • Store the operation and installation manual in a safe 

location and remember to hand it over to the new 

owner if the air conditioner is sold or transferred. 

 • This manual explains how to install an indoor unit with 

a split system with two SAMSUNG units. The use of 

other types of units with different control systems may 

damage the units and invalidate the warranty. The 

manufacturer shall not be responsible for damages 

arising from the use of non compliant units. 

 • The manufacturer shall not be responsible for damage 

originating from unauthorized changes or the improper 

connection of electric and hydraulic lines. Failure to 

comply with these instructions or to comply with the 

requirements set forth in the “Operating limits” table, 

included in the manual, shall immediately invalidate 

the warranty.

 • The air conditioner should be used only for the 

applications for which it has been designed: the indoor 

unit is not suitable to be installed in areas used for 

laundry. 

 • Do not use the units if damaged. If problems occur, 

switch the unit off and disconnect it from the power 

supply.

 • In order to prevent electric shocks, fires or injuries, 

always stop the unit, disable the protection switch 

and contact SAMSUNG’s technical support if the unit 

produces smoke, if the power cable is hot or damaged 

or if the unit is very noisy. 

 • Always remember to inspect the unit, electric 

connections, refrigerant tubes and protections 

regularly. These operations should be performed by 

qualified personnel only. 

 • The unit contains moving parts, which should always be 

kept out of the reach of children. 

 • Do not attempt to repair, move, alter or reinstall the 

unit. If performed by unauthorized personnel, these 

operations may cause electric shocks or fires.

 • Do not place containers with liquids or other objects 

on the unit. 

 • All the materials used for the manufacture and 

packaging of the air conditioner are recyclable. 

 • The packing material and exhaust batteries of the 

remote control (optional) must be disposed of in 

accordance with current laws.

 • The air conditioner contains a refrigerant that has to be 

disposed of as special waste. At the end of its life cycle, 

the air conditioner must be disposed of in authorized 

centers or returned to the retailer so that it can be 

disposed of correctly and safely.

Installing the unit

 • IMPORTANT: When installing the unit, always 

remember to connect first the refrigerant tubes, then 

the electrical lines. Always disassemble the electric 

lines before the refrigerant tubes. 

 • Upon receipt, inspect the product to verify that it has 

not been damaged during transport. If the product 

appears damaged, DO NOT INSTALL it and immediately 

report the damage to the carrier or retailer (if the 

installer or the authorized technician has collected the 

material from the retailer.)

 • After completing the installation, always carry out a 

functional test and provide the instructions on how to 

operate the air conditioner to the user.

 • Do not use the air conditioner in environments with 

hazardous substances or close to equipment that 

release free flames to avoid the occurrence of fires, 

explosions or injuries. 

 • The air conditioner should be used only for the 

applications for which it has been designed: the indoor 

unit is not suitable to be installed in areas used for 

laundry.

Safety Information

Safety Information

DB68-08953A-00_IM_DVM QMD_EU_EN_.indd   3

2020-02-10   오후 4:23:06

Содержание AM TNVD Series

Страница 1: ...anual AM TNVD AM TNAD Thank you for purchasing this Samsung air conditioner Beforeoperatingthisunit pleasereadthisinstallationmanualcarefullyandretainitforfuturereference DB68 08953A 00_IM_DVM QMD_EU_...

Страница 2: ...aring the pipes 8 Step 7 Performing leak test 9 Step 8 Wrapping the pipes with the insulation 9 Step 9 Installing the drain hose 10 Step10 Optional Changing direction of the drain hose 10 Step11 Conne...

Страница 3: ...if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These...

Страница 4: ...power cable modification extension wiring and multiple wire connection It may cause electric shock or fire due to poor connection poor insulation or current limit override When extension wiring is re...

Страница 5: ...the remote control can be operated well A place where the air filter can be replaced easily CAUTION Do not install the product with EEV commercial model in a quiet place such as bedroom hotel and hosp...

Страница 6: ...plate to the wall giving attention to the weight of the indoor unit Level Screw Location x 4ea NOTE If you mount the plate to a concrete wall by using plastic anchors make sure that gaps between the w...

Страница 7: ...h the cut edges 3 Remove the protection caps of the pipes and connect the assembly pipe to each pipe Tighten the nuts first with yourhands and then with a torque wrench applying the following torque R...

Страница 8: ...ring tool Unit mm Outer diameter A Flare tool for R410Aclutch type Conventional flare tool Clutch type Wing nut type 6 35 0 0 5 1 0 1 5 1 5 2 0 9 52 0 0 5 1 0 1 5 1 5 2 0 12 7 0 0 5 1 0 1 5 1 5 2 0 15...

Страница 9: ...the pipe hose and cables Then place the indoorunit on the installation plate 1 To avoid condensation problems place heat resistant poly ethylene foam separately around each refrigerant pipe in the lo...

Страница 10: ...e NOTE If you don t use the other drain hose hole block it with a rubber stopper 4 Pass the drain hose underthe refrigerant pipe keeping the drain hose tight 5 Pass the drain hose through the hole in...

Страница 11: ...es at the back side of the indoor unit when installing the wired remote control V1 F1 1 L 2 N F2 F1 1 L 2 N 1 L 2 N F2 F1 F2 F1 F2 F1 F2 F1 F2 N L N L N L N L F1 F2 1 L 2 N F1 F2 F1 1 L 2 N F2 F1 1 L...

Страница 12: ...0 1 s 2 5 mm 2 5 mm 0 75 1 5 mm Refer to the unit nameplate for rating current Decide the capacity of ELCB or MCCB ELB by below formula Power supply cords of parts of appliances for outdoor use shall...

Страница 13: ...t local and national regulations Wire size must comply with local and national code For the power cable use the grade of H07RN F or H05RN F materials You should connect the power cable into the power...

Страница 14: ...terminal screws Tightening torque N m kgf cm M 3 5 0 8 1 2 8 0 12 0 M 4 1 2 1 8 12 0 18 0 Step12 Optional Extending the power cable 1 Prepare the following tools Tools Spec Shape Crimping pliers MH 1...

Страница 15: ...tube in the middle of the insulation tape 40 mm Insulation tape Method1 35 mm Insulation tape Method 2 6 Apply heat to the contraction tube to contract it Contraction tube Method1 Contraction tube Me...

Страница 16: ...imer Wind Free Direction 1 Remove batteries from the remote control 2 Insert batteries and enterthe option setting mode while pressing High Temp button and Low Temp button 3 Check if you have entered...

Страница 17: ...us 5 Setting SEG6 SEG8 option a Press Low Fan button to enterSEG6 value b Press High Fan button to enterSEG8 value Each time you press the button will be selected in rotation SEG6 SEG8 6 Setting Fan m...

Страница 18: ...ch time you press the button will be selected in rotation SEG16 SEG17 14 Setting Dry mode Press Mode button to be changed to Dry mode in the OFF status 15 Setting SEG18 SEG20 option a Press Low Fan bu...

Страница 19: ...t is correct ornot SEG2 SEG3 SEG21 SEG22 SEG23 SEG24 SEG4 SEG5 SEG6 SEG8 SEG9 SEG10 SEG11 SEG12 SEG14 SEG15 SEG16 SEG17 SEG18 SEG20 6 Press the button with the direction of remote control forset Forth...

Страница 20: ...Indication and Details Indication Details Indication Details Indication Details Indication Details 1 0 No RMC address RMC1 0 F RMC2 0 F 1 RMC address setting mode CAUTION When A F is entered to SEG5...

Страница 21: ...will be set as 0 SEG5 central control option is basically set as 1 Use so you don t need to set the central control option additionally However if the central control is not connected but it doesn t i...

Страница 22: ...atisoff 0 2 0 Default Default 1 Use Disuse 2 Disuse Use Heating 1 3 Use Use Heating 1 4 Disuse Use Cooling 1 5 Use Use Cooling 1 6 Disuse Use Heating Cooling 1 7 Use Use Heating Cooling 1 8 Disuse Use...

Страница 23: ...e Use 4 MaintainbladestatusinWind Freemode Useeveryfanmode Disuse 5 Coolingoperationbyopening theblade Useeveryfanmode Disuse 6 MaintainbladestatusinWind Freemode UseonlyWind Free mode Disuse 7 Coolin...

Страница 24: ...turnorNoise decreasingindefrost mode 5 5 C Use 8 1 Minimizing fan operation when thermostat is off Fan operates for 20 seconds at an interval of 5 minutes in heat mode Fan stops or operates Ultra low...

Страница 25: ...to off for cooling only indoor unit by setting the SEG15 3 you need to use an external sensor orwired remote controller sensor to detect indoor temperature exactly 5 When indoorunit is in cooling orD...

Страница 26: ...G20 SEG21 SEG22 SEG23 SEG24 3 Forced FAN Operation for Heating and Cooling 05 series installation option Detailed Option No 02XXXX 1XXXXX 2XXXXX 3XXXXX Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation...

Страница 27: ...C 3 11min 4 3 C 4 13min 2 1 Heightdifference is15 30mor 2 Distanceis50 110m 2 Use 5 3 5 C 5 15min 6 4 C 6 20min 7 4 5 C 7 30min Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 Explanation Controlvariablesw...

Страница 28: ...tion 1 2 Distance The difference between the pipe length of the indoorunit installed at farthest place from an outdoorunit and the pipe length of the corresponding indoorunit from an outdoorunit Forex...

Страница 29: ...forCooling A Set with SEG4 C B Set with SEG5 C C Set with SEG6 C D Set with SEG8 C Standard temp for Cooling Heating Cooling thermo off Cooling thermo on Heating thermo off Heating thermo on Standard...

Страница 30: ...ress setting option set the SEG3 as A When changing a digit of indoor unit installation option set the SEG3 as 2 Ex When setting the buzzercontrol into disuse status Option SEG1 SEG2 SEG3 SEG4 SEG5 SE...

Страница 31: ...ditioner operates according to the selected mode or function 4 Press the button and check the following The airflow blades work properly 5 Press the button and check the following The airflow blades w...

Страница 32: ...ensor E221 2 Erroron cond sensor E237 3 Erroron discharge sensor E251 Otheroutdoorunit sensorerrors that are not on the above list 1 When there is no communication between the indoorand outdoorunits f...

Страница 33: ...ve 1st detection E180 15 Simultaneous opening of cooling heating MCU SOLvalve 2nd detection E181 Otheroutdoorunit self diagnosis errors that are not on the above list External contact input error E665...

Страница 34: ...DB68 08953A 00_IM_DVM QMD_EU_EN_ indd 34 2020 02 10 4 23 12...

Отзывы: