ENGLISH
Evacuating the indoor unit
t
The remaining air in the Refrigeration cycle, which contains moisture,
may cause malfunction on the compressor.
t
Always contact the service center or a professional installation agency
for product installation.
t
To prevent dirt or foreign substances from getting into the pipes
during installation, do NOT remove the caps completely until you are
ready to connect the pipes.
If you need a pipe longer than 13.1 or 16.4 fts (4 or 5 meters):
t
You must add refrigerant to the pipes; otherwise, the indoor unit may freeze.
Cutting or extending the pipe
1. Unscrew the caps at the end of each pipe.
f
All inert gas exhausts from the indoor unit.
The indoor unit is supplied with inert gas (nitrogen).
#FGPSFJOTUBMMJOHUIFVOJUDIFDLJGOJUSPHFOHBTøPXPVUPGJOEPPSVOJU
*GUIJTPOFJTOUUSVF%0/05*/45"--5)&6/*5TJODFMFBLBHFDPVMECFJOTJEFUIFJOEPPSVOJU
Unscrew the
caps
Pipes
Assembling the hanger screw and guide
1. Cut out the knock-out piece according to the drain hose direction before
fixing the indoor unit.
2. Fix the indoor unit on the wall.
Pass the
cables, pipes and hose
through the hole which would be connected
to the outdoor unit .
3. Use 2 screws to fix the indoor unit as shown in the picture.
4. Assemble the Guide into the position where the knock-out piece has been cut
out before.
There’re three hooks on the Guide, they must be totally fixed to the unit.
❋
The method of assembling the Guide is same whether it’s on right or on left.
-FGUBOESJHIUFBDIIBTPOF
LOPDLPVUQJFDF
Guide
Screw
CAUTION
CAUTION
English-11