Hydro Unit HT
2.. Specification
Model CODE
AM048CNBFCB/AA
AM072CNBFCB/AA
Power Supply
Φ, #, V, Hz
1,2,208-230,60
1,2,208-230,60
Mode
-
HEAT PUMP
HEAT PUMP
Performance
Capacity
(Nominal)
Heating
Btu/h
54,500
86,000
Power
Power Input
(Nominal)
W
Heating
3100
5000
Current Input
(Nominal)
A
Heating
14.3
23.1
Compressor
Type
-
Rotary
Rotary
Output
kW x n
-
-
Model Name
-
UX5T250FNBEX
UX5T250FNBEX
Oil
Type
-
POE
POE
Initial Charge
cc
1,700
1,700
Heat Exchanger
Type
-
PHE
PHE
Quantity
-
2
2
Pipe Size
Φ, inch
NPT 1
NPT 1
Water Flow Rate
LPM
23
36
GPM
6.1
9.5
Flow Switch
LPM
12
12
GPM
3.2
3.2
Option Code
-
01104C-105000
20A0A0-332200
01104C-105000
20FAFA-332100
Piping
Connections
Liquid Pipe
Φ, inch
3/8
3/8
Gas Pipe
Φ, inch
5/8
5/8
Drain Pipe
Field
Wiring
Power Source Wire
Transmission Cable
Refrigerant
Type
-
R410A / R134a
R410A / R134a
Control Method
-
EEV INCLUDED
EEV INCLUDED
Sound
Sound Pressure
dB(A)
42
42
Dimensions
Net Weight
lbs
233.7
233.7
Shipping Weight
lbs
250.2
250.2
Net Dimensions (W×H×D)
inch
20.4x47.6x13.0
20.4x47.6x13.0
Shipping Dimensions (W×H×D)
inch
25.7x54.1x16.8
25.7x54.1x16.8
Temp
Max. Outdoor Ambient
Operating Temp.
Heating
109.4
109.4
Operating Water Temp. Range
77~176
77~176
℉
℉
Heating
3/4
3/4
AWG
6
6
AWG
18
18
Φ, inch
Min.
NOTE
*
Specifications may be subject to change without prior notice for product improvement.
*
1) Nominal heating capacities are based on;
Water temperature : 131°F(55°C) inlet, 149°F(65°C) outlet
Indoor temperature : 68°F(20°C) DB
Outdoor temperature :44.6°F(7°C) DB, 42.8°F(6°C) WB
*
2) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
*
3) The VRF system contains R410A (GWP=2,088) which is fluorinated greenhouse gas.
*
Heat Exchanger type : Plate Heat Exchanger (STS)