26
A
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel (display) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an option to the indoor unit according
to the airconditioning system plan.
- The default setting of an indoor unit installation option is “02000-100000-
200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an indoor unit individually when there is
more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
- When entering address option, connect remote controller receiver.
Indoor Unit
1(L)
F2
2(N)
F1
◆
AJ***JNND**/AJ***JNAD**
◆
AJ***JNLD**
No.
Function
On
Off
SW05
K1
External room sesor
Disuse
Use
K2
Centralized controller
Disuse
Use
K3
-
-
-
K4
Drain Pump
Disuse
Use
SW06
K5
Indoor Temperature Compensation for Heating
Mode
+2 °C(35.6 °F)
+5 °C(41 ° F)
+5 °C(41° F)
+2 °C(35.6 °F)
K6
Filter Time
1,000h
2,000h
K7
Hot Water Coil
Disuse
Use
K8
-
-
-
SW07
K9
-
-
-
K10
-
-
-
K11
External Control
Disuse
Use
K12
External Control Output
Thermal ON
Operation ON
K1 K2 K3 K4
SW05
K5 K6 K7 K8
SW06
K9 K10 K11 K12
SW07
How to use additional function