313
※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB
on pvi.Samsung.com site or Global Partner Portal site.
13. Installation
◆ AJ052/068TXJ3KG
1
Piping outside diameter
Indoor unit
Out unit
Power
supply Ø,
V, Hz
Outside
diameter
Liquid Gas
AR07/09/12********,
AJ016/020/026
/035TN*D*G
AJ052TXJ3KG
AJ068TXJ3KG
1,220-240,
50
1/4"
3/8"
AR18********,
AJ052TN*D*G
1/2”
A
B
Main power switch
(h) (H)
C
NOTE
•
AJ052TXJ3KG Outdoor unit cannot be connected to
the following indoor unit combination.
- AJ052TNNDKG/AJ052TNMDEG
•
AJ068TXJ3KG Outdoor unit cannot be connected to
the following indoor unit combination.
- AJ***TNJDKG
2
Piping outside diameter
1 Room max
length
3 Room total
max
length
Max height
between
indoor unit &
outdoor unit
Max height
between
indoor units
Dimension
25m
50m
15m
7.5m
Composition
A,B,C
A+B+C
(H)
(h)
Make at least one round:
It will reduce noise and vibration
◆ AJ080TXJ4KG
1
Piping outside diameter
Indoor unit
Out unit
Power
supply Ø, V,
Hz
Outside
diameter
Liquid Gas
AR07/09/12********,
AJ016/020/026
/035TN*D*G
AJ080TXJ4KG 1,220-240, 50
1/4"
3/8"
AR18********,
AJ052TN*D*G
1/2”
AR24********
5/8”
A
B
(h) (H)
C
D
Main power switch
NOTE
•
AJ080TXJ4KG Outdoor unit cannot be connected to
the following indoor unit combination.
- AJ***TNJDKG
2
Piping length and the height
1 Room
max
length
4 Room
total max
length
Max height
between
indoor unit &
outdoor unit
Max height
between
indoor units
Dimension
25m
70m
15m
7.5m
Composition
A,B,C,D
A+B+C+D
(H)
(h)
Make at least one round:
It will reduce noise and vibration