304
※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB
on pvi.Samsung.com site or Global Partner Portal site.
13. Installation
13. Installation
Choosing the installation location
Installation location requirements
•
The outdoor unit shall be installed in an open space
that is always ventilated.
•
The local gas regulations shall be observed.
•
For installation inside a building (this applies
either to indoor or outdoor units installed inside) a
minimum room floor area of space conditioned is
mandatory according to IEC 60335-2-40:2018 (see
the reference table into either the indoor or outdoor
unit installation manual).
•
To handle, purge, and dispose the refrigerant, or
break into the refrigerant circuit, the worker should
have a certificate from an industry-accredited
authority.
•
Do not install the indoor unit in the following areas:
-
Area filled with minerals, splashed oil, or steam.
It will deteriorate plastic parts, causing failure or
leakage.
- Area that is close to heat sources.
- Area that produces substances such as sulfuric
gas, chlorine gas, acid, and alkali. It may cause
corrosion of the pipings and brazed joints.
- Area that can cause leakage of combustible gas
and suspension of carbon fibers, flammable
dust, or volatile flammables.
- Area where refrigerant leaks and settles.
- Area where animals may urinate on the product.
Ammonia may be generated.
•
Do not use the indoor unit for preservation of food
items, plants, equipment, and art works. This may
cause deterioration of their quality.
•
Do not install the indoor unit if it has any drainage
problem.
•
Do not place the outdoor unit on its side or upside
down. Failing to do so may cause the compressor
lubrication oil to run into the cooling circuit and lead
to a serious damage to the unit.
•
Install the unit in a well-ventilated location away
from direct sunlight or strong winds.
•
Install the unit in a location that would not obstruct
any passageways or thoroughfares.
•
Install the unit in a location that would not inconvenience
or disturb your neighbors, as they could be affected by the
noise or the airflow coming from the unit.
•
Install the unit in a location where the pipes and the cables
can be easily connected to the indoor unit.
• Install the unit on a flat, stable surface that can withstand
the weight of the unit. Otherwise, the unit can generate
noise and vibration during operation.
• Install the unit so that the air flow is directed towards the
open area.
• Maintain sufficient clearance around the outdoor
unit, especially from a radio, computer, stereo
system, etc.
Fuse
Fuse
Control
1.5 m or
mor
e
1 m or
mor
e
1 m or
mor
e
1.5 m or more
1.5 m or more
300 mm
StereoComputer etc
Outdoor Unit
200 mm
Air Guide Duct (This product is not provided by Samsung)
Indoor Unit
•
Install the unit at a height where its base can be
firmly fixed in place.
•
Make sure that the water dripping from the drain
hose runs away correctly and safely.