background image

7-14

Samsung Electronics

Q

The remote controller won't operate.  

A

When the batteries run out or the transmitter or receiver of the remote controller is blocked by obsta-

cles, change the batteries or keep the obstacles away from the controlling area. Also, the remote con-

troller may not work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. 

In this case, take the remote controller closer to the receiver.   

Who installs the air conditioner? (Relocation/Re-installation)   

A

When relocating or re-installing the air conditioner, make sure to contact Samsung Electronics Service

Center or Authorized Service Agent and have them to do the job.(If not, it could cause personal injury

or product damage.)

The cost for the relocation/re-installation of the air conditioner is subject to the customer's expense.

There is a cost table. But, our service engineer needs to visit to total up the cost correctly. 

When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service

Agent in advance to streamline the process.

Is it possible to install the outdoor unit outside?   

A

It is possible to install it at a designated place in the apartment or on the rooftop nearby. 

But, it's illegal hanging an angle iron case with the outdoor unit in it outside the apartment. Also, it is

illegal obstructing passers-by with the outdoor unit installed outside.

Q  

What can be done to install the outdoor unit facing the road because it is a commercial building?

A

The following is an excerpt from Building Code going into effect from JUNE 1st 2005. "The exhaust

pipe of a cooling or ventilation facility installed in a building adjacent to the streets of commercial or

residential areas shall be installed higher than 2m to prevent the exhaust air from blowing directly to

passers-by and the current facilities shall be corrected by MAY 31st 2005." So, please install it higher

than 2m or not to blow the hot exhausting air directly to passers-by.   

Q  

What about installing a windscreen during installation not to blow hot air directly to passers-by? 

A

When the hot air from the front of the outdoor unit is blocked, the product's performance will be 

affected and it will fail to operate properly. So, keep it at least 300mm away from its surrounding walls

and give it good ventilation. 

Operation

Installation

Classification

Class

Description

Q & A for Non-trouble (cont.)

Содержание AJ009JNNDCH FJM series

Страница 1: ...l name AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH AJ007JNADCH AJ009JNADCH AJ012JNADCH Model code AJ009JNNDCH AA AJ012JNNDCH AA AJ018JNNDCH AA AJ007JNADCH AA AJ009JNADCH AA AJ012JNADCH AA AJ018JNADCH AJ024JNA...

Страница 2: ...Checking and Testing operation 4 16 4 5 Fault Diagnosis by Symptom 4 24 4 5 1 Indoor 4 24 4 5 1 1 Indoor temperature sensor open short 4 24 4 5 1 2 Indoor FAN Error BLDC MOTOR MODEL 4 25 4 5 1 3 Comm...

Страница 3: ...es such as the power cable and the connection cord in pipes ducts or cable channels to protect them from the danger of impact or any other incidents O More than 2 indoor units should be installed when...

Страница 4: ...high It may cause explosion and injury O Pump Down Procedure When removing the product Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes Release the valve caps on Hi...

Страница 5: ...Various Indoor units combinations t JOJ XBZ DBTTFUUF t 4MJN EVDU t Convenient Installation Auto addressing option Automated checking of pipe connection Refer to the installation manual for detail Spac...

Страница 6: ...3 SLIT NGS Option Code 015201 14023E 200001 300000 015201 160370 200001 300000 011224 1940E6 200001 300000 ITEM AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH INDOOR UNIT Type Mini 4 way cassette Performance Co...

Страница 7: ...fin hydrophile 7 F P1 3 H fin NGS Option Code 010025 15622A 27323C 372604 010025 15625C 274450 372604 ITEM AJ007JNADCH AJ009JNADCH AJ012JNADCH INDOOR UNIT Type Wall mounted Performance Cooling Btu h...

Страница 8: ...940 998 330 Net Weight kg 57 3 65 0 75 5 Compressor Type Twin BLDC Rotary Model name UG4T200FUAE4 G8T260FUAEW UG8T300FUBJU Motor Type BLDC Lubricant Oil Type POE Capacity cc 650 700 1200 Protection D...

Страница 9: ...kg Dimemsion Indoor Unit AJ007 009 012JNADCH 826 275 260 mm AJ009 012JNNDCH 575 250 575 mm AJ009 012JNLDCH 900 199 600 mm Outdoor Unit AJ020JCJ2CH 880 798 310 mm Noise Indoor Unit AJ007 009JNADCH 45 d...

Страница 10: ...Unit AJ007 009 012JNADCH 826 275 260 mm AJ018JNADCH 1063 317 294 mm AJ009 012 018JNNDCH 575 250 575 mm AJ009 012JNLDCH 900 199 600 mm AJ018JNLDCH 1100 199 600 mm Outdoor Unit AJ024JCJ3CH 880 798 310...

Страница 11: ...275 260 mm AJ018 024JNADCH 1063 317 294 mm AJ009 012 018JNNDCH 575 250 575 mm AJ009 012JNLDCH 900 199 600 mm AJ018JNLDCH 1100 199 600 mm Outdoor Unit AJ036JCJ5CH 940 998 330 mm Noise Indoor Unit AJ00...

Страница 12: ...NSTRU ES MANUEL D UTILISATION GEBRAUCHSANWEISUNG Splut type Room Air Conditioner Aire acondicionado dom stico sistema Split Condizionatore d aria per ambienti ad unit Separate Aparelho de ar condicion...

Страница 13: ...e 1 Remote Control DB93 14643R 1 Batteries for Remote Control 4301 000121 2 User s Manual DB68 04992A 1 Installation Manual DB68 04993A 1 Cap Screws DB67 01404A 1 Case Sub PCB DB61 06101A 1 CARDWARRAN...

Страница 14: ...ss y DB62 11028A 1 Seal drain ass y DB62 11028H 1 Seal drain ass y DB62 11028J 1 USER MANUAL DB68 04990A 1 GARANTIE CARD DB98 13261A 1 ASSY INSTALLATION MANUAL DB68 04991A 1 CARD WARRANTY DB68 01675A...

Страница 15: ...DB68 05062B AJ024JCJ3CH 2 Rubber Leg DB73 20134A 4 Flare Nuts 9 52mm outer pipe diameter DB60 30010B Only for AJ024JCJ3CH 1 Installation Manual DB68 04989A 1 Nipple Connector DB67 00788A Only for AJ02...

Страница 16: ...in Plug Out DB67 00806A 1 Outdoor Unit Energy Label DB68 05115A 2 Rubber Leg DB73 20134A 4 Cap Drain DB63 10355C 3 Installation Manual DB68 05013A 1 Flare Nuts 3 8 DB96 16155A 3 Flare Nuts 5 8 DB96 16...

Страница 17: ...Samsung Electronics 3 1 3 Disassembly and Reassembly Necessary Tools Item Remark SCREW DRIVER MONKEY SPANNER...

Страница 18: ...e AJ007JNADCH AJ009JNADCH AJ012JNADCH AJ018JNADCH AJ024JNADCH No Parts Procedure Remark 1 PANEL FRONT 1 Stop the driving of air conditioner and shut off main power supply 2 Detach FILTER PRE from the...

Страница 19: ...d to body by Hook in center area and side area 5 Separate the hook after pushing both end of Cover Panel as shown in the gure Watch out for the damage of the hook 6 Raise front part upward obliquely a...

Страница 20: ...ure Remark Caution Assembly of Cover Panel after service end Reassembly is in the reverse order of the removal Piping and drain hose must be careful not to damage and Progress must be done with both h...

Страница 21: ...n frame unfasten 2 screws at the bottom use Screw Driver 8 To detach the COVER PANEL from the main frame loosen 4 HOOK Structures When separate the hook Use the screw Driver Screw Driver Insert the ho...

Страница 22: ...3 6 Samsung Electronics No Parts Procedure Remark 9 Remove the Panel Frame from the Main Frame as shown on the right side...

Страница 23: ...ire Caution When you separate the connector pull pressing the locking button 3 Loosen the terminal block wires Caution When you separate the connector pull pressing the locking button 4 Loosen the The...

Страница 24: ...5 Take off the CASE CONTROL from the main frame after loosen the remaining con nector Caution When you separate the connector pull pressing the locking button 3 TRAY DRAIN 1 To detach TRAY DRAIN from...

Страница 25: ...emark 4 Evaporator 1 Detach the HOLDER PIPE 2 Unfasten the screw at the left side use Screw Driver 3 Unfasten the screw at the right side use Screw Driver 4 To detach Evaporator from the main frame pu...

Страница 26: ...Electronics No Parts Procedure Remark 5 FAN MOTOR CROSS FAN 1 Unfasten the screw use Screw Driver 2 Detach the FAN Motor case 3 Unfasten the screw a little use Screw Driver 4 Pull the CROSS FAN to th...

Страница 27: ...tor Blower 1 Disassemble the Cabinet Top Motor Unscrew 8 screws 2 Disassemble 2 Cover Blower Uppers After unscrewing 2 screws Disassemble the Cover Blower Upper with pushing its hook 3 Disassemble the...

Страница 28: ...he inside of PCB and connected to the Capacitor 5 Disassemble the Motor earth wire connected to the Partition Unscrew a screw 6 Disassemble the band Motor for fixing the Motor Unscrew 2 screws 7 After...

Страница 29: ...ocedure Remark 2 Drain Pan 1 Disassemble the Cabinet Top Evap Unscrew 11 screws 2 Disassemble the Bracket Outlet Sub that fixes the Drain Pan equipped on the front of the set Unscrew 6 screws 3 Disass...

Страница 30: ...Control 1 3 and the Drain Pan 2 1 2 2 2 3 1 Disassemble the Cover Pipe that fixes the high low pressure Pipe Unscrew 3 screws 2 Disassemble the refrigerant temperature sensor Inlet air temperature sen...

Страница 31: ...l Wires connected to the inside of PCB 2 In case of disassembling the PCB separately disassemble the PCB from the case with pushing the hook after unscrewing the screw Unscrew 1 screw 3 Disassemble th...

Страница 32: ...3 16 Samsung Electronics AJ018JNLDCH No Parts Procedure Remark 1 Filter 1 Pull out the Filter as picture 1 or picture 2...

Страница 33: ...e Remark 2 Blower Motor 1 After disassembling 13 indicating screws detach Ass y Cabinet Top Motor 2 After disassembling 3 indicating screws detach Ass y Case Blower Upper Press the pothook of the Case...

Страница 34: ...embling 2 indicating screws detach the Cover Control 4 Detach the Motor Wire Connected to PCB and Capacitor 5 After disassembling the indicating screws detach the wire connected to the Partition 6 Aft...

Страница 35: ...the Motor and Blowers detach the Blowers from the axis of the Motor by 3mm inner hexagon spanner 3 Drain Pan 1 After disassembling 12 indicating screws detach Ass y Cabinet Top Evap 2 After disassembl...

Страница 36: ...1 3 and the Drain Pan 2 1 2 2 2 3 1 Disassemble the Cover Pipe that fixes the high low pressure Pipe Unscrew 3 screws 2 Disassemble the refrigerant temperature sen sor Inlet air temperature sensor 3...

Страница 37: ...Cover Control 1 3 1 Disassemble all Control Wires connected to the inside of PCB 2 In case of disassembling the PCB separately disassemble the PCB from the case with pushing the hook 3 Disassemble th...

Страница 38: ...the front grille to prevent it from dropping 2 Detach the safity clip and take up the grille 3 Remove the 2 fixed screws to remove the Control Box Cover Use Screw Driver 4 Remove the Remocon Receiver...

Страница 39: ...he Hangers at both sides of the panel inwards to remove it from the indoor unit s hook Remove the panel from the indoor unit 2 Control Box 1 Disconnect the Connector Wire that is con nected to the ind...

Страница 40: ...rew fixed on the Bell Mouth Use Screw Driver 2 Push the Bell Mouth in the direction oppo site to where it s installed on the Control Box to remove it 4 Drain Pan 1 Unscrew the screws on the 4 corners...

Страница 41: ...e from the Drain Pump Use Screw Driver 2 Remove the 2 screws and take the Drain Hose out from the indoor unit to disas semble the transparent Drain Hose fixed on the side of the indoor unit Use Screw...

Страница 42: ...gular nuts on the Motor counterclockwise to remove the nuts Take the Motor Wires attached to these three locations out with your hands prior to remov ing the Motor 8 Evaporator 1 Remove the screws of...

Страница 43: ...ctronics 3 27 No Parts Procedure Remark 3 Remove the screw of the Cover Pipe that is used to fix the In Out Pipe Remove the In Out Pipe Use Screw Driver 4 Remove the Heat Exchanger from the indoor uni...

Страница 44: ...re Remark 1 Common Work Control Out You must turn off the Power before disassembly 1 Loosen 7 fixing screws and detach the Cabinet side RH Use Screw Driver 2 Detach the Cable Connector Wire from the T...

Страница 45: ...ung Electronics 3 29 No Parts Procedure Remark 6 Loosen 2 fixing screw and pull up the Control Box Use Screw Driver 7 Pull the felt and detach it 8 Detach the Terminal Cover and detach the comp lead w...

Страница 46: ...Use Screw Driver 3 Loosen 4 fixing bolts and detach the Bracket Motor Use Screw Driver 3 Heat Exchanger Compressor 1 Release the refrigerant at first 2 Disassemble the Inlet and Outlet Pipe by welding...

Страница 47: ...ff the Power before disassembly 1 Unscrew and remove 6 mounting screw in the Cabinet Side RH Use Screw Driver 2 Cabi Front RH 1 Unscrew and remove 6 mounting screw in the Cabinet Side RH Use Screw Dri...

Страница 48: ...ensor from Guard Cond 2 Unscrew and remove 4 screws in the Guard Cond Use Screw Driver 5 Cabi Back RH 1 Pull the sensor from Cabi Back RH 2 Unscrew and remove 5 screws on each side of the Cabinet Back...

Страница 49: ...No Parts Procedure Remark 6 Plate Case Control Support 1 Unscrew and remove 2 screws in the plate Case control Support Use Screw Driver 7 Cabi Back RH 1 Unscrew and remove 10 screws in the Cabinet Fr...

Страница 50: ...the picture and remove it Use Adjustable Wrench 9 Motor 1 Separate the Fan Propeller 2 Unscrew and remove the 8 Motor mounting screws Use Screw Driver 3 Disconnect the Motor wire From Ass y Control Ou...

Страница 51: ...Electronics 3 35 No Parts Procedure Remark 11 Control Out 1 Disconnect 9 Connecters From Ass y Control Out 2 3 Unscrew and remote 2 mounting screw in Control Out Use Screw Driver Separate Ass y Contr...

Страница 52: ...the compressor Heat Exchanger and Pipe purge the Coolant inside the Compressor completely and remove the pipe with a welding ame 13 Assy EEV Valve 1 Separate the pipe from the Entrance Exit using a we...

Страница 53: ...re Remark 2 Separate the Compressor Felt Sound 3 As shown in the picture unscrew and remove 3 mounting screws from the bottom Use Adjustable Wrench 15 Cond Out 1 Unscrew and remove 3 screws on each si...

Страница 54: ...3 38 Samsung Electronics MEMO...

Страница 55: ...t X X Error of fan motor in the indoor unit X X X Error of the outdoor temperature sensor Error of the condensor temperature sensor Error of the discharge temperature sensor X X No communication for 2...

Страница 56: ...Displayed on outdoor unit 1 No communication for 2 minutes between indoor units Communication error for more than 2 minutes 2 Indoor unit receiving the communication error from outdoor unit 3 Outdoor...

Страница 57: ...unit which is oper ating Displayed on outdoor unit 5 Breakaway of COND MID sensor 6 2nd detection of refrigerant completely leak 7 2nd detection of high temperature COND 8 2nd detection of high tempe...

Страница 58: ...oncable iscrossedornot Erroronindoor temperaturesensor 1 Checktheconnectionoftheconnector Erroronindoorheat exchanger 1 Checktheconnectionoftheconnector Erroronindoorfanmotor 1 Checktheconnectionofthe...

Страница 59: ...allationthroughautoaddressingmodewithoutpipecheckoperation Check setting The number of Indoor unit mismatched Check electrical connection and setting Communication error between the outdoor and indoor...

Страница 60: ...indoor unit s Self diagnosis Outdoor unit EEV open operating indoor unit s Self diagnosis High temperature over 30 C of outdoor as heating mode Low temperature under 10 C of outdoor as cooling mode Ou...

Страница 61: ...time you press High Fan button 7 seg on right side is increased by 1 4 You press button to move to the next setteing page 5 After setting option press button to check whether the option code you inpu...

Страница 62: ...n the ON status 1 Press Low Fan button to enter SEG11 value 2 Press High Fan button to enter SEG12value Step 7 Press Mode button to be changed to AUTO mode in the OFF status 1 Press Fan button to ente...

Страница 63: ...G3 SEG4 SEG5 SEG6 Explanation PAGE MODE Setting Main address 100 digit of indoor unit address 10 digit of indoor unit A single digit of indoor unit Remote Controller Display Indication andDetails Indi...

Страница 64: ...ils Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 1 0 0 0 0 0 Slave 1 Master Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 Explanation...

Страница 65: ...044217 1d00e6 200003 300000 Not in use Use Change temperature display 0 Celsius 1 Fahrenheit Sound Mute 0 2 4 2 2 Changing a particular option MODEL OPTION CODE AJ007JNADCH 010025 16623A 271416 372A0...

Страница 66: ...ntly in HEAT mode Indoor fan and outdoor fan stop operation intermittently in a HEAT mode The compressor stops intermittently in a COOL mode or DRY mode and fan speed of the indoor unit decreases Expl...

Страница 67: ...l units are connected display in sequence on the display of the external unit Display1 Display2 Description The outdoor unit is communication correctly together the in door unit connected to refrigera...

Страница 68: ...y of outdoor unit display PCB DIS01 will count fom 00 01 02 to 15 Estabilished communication the left display will count sequentially 00 communication with indoor unit A 01 communication with indoor u...

Страница 69: ...Please do cool mode try run or heat mode try run Cool mode try run Push the K2 button three times Heat mode try run Push the K2 button once After 12 minutes of stationary condition check each indoor u...

Страница 70: ...of the external unit WARNING Do not adjust the Ampere Limit Switch if it s not necessary before modifying it evaluate the total number of electric and electronics loads consumption and use Ampere lim...

Страница 71: ...650 PS 6 t EESFTT OVNCFS PO FBDI JOEPPS VOJU BOVBM BEESFTTJOH NPEF t PSSFDU PQFSBUJPO GPS QJQF DIFDLJOH DPOOFDUJPO GPMMPX UIF TUFQ CFMPX t G UIF BVUP BEESFTTJOH SFGFS UP OFYU QBHF t G UIF NBOVBM BEES...

Страница 72: ...e setting time Outdoor Temperature or more less than Cool mode Heat mode 5min 10min 20min 50min Button K1 1 times DIS 01 DIS 02 Display Time duration 2 Apply the power to the outdoor unit Outdoor unit...

Страница 73: ...ber MAX Installation ID Unit Number of OD Unit Don t need set SW01 2 Installation ID Unit Number MAX Installation ID Unit Number of OD Unit Pls set SW01 as the number of which you install the indoor u...

Страница 74: ...error open short Indoor unit heat exchanger out temperature sensor error open short Indoor unite fan error Please all units turn off and check to indoor unit s PCB and wire connection E121 122 123 er...

Страница 75: ...id pipes are crossed with each other check to connecting Pipe connecting Check to outdoor unit s EEV coil being connected in proper location EEV Coil Check to indoor unit s sensor being connected in p...

Страница 76: ...alation of another outdoor air flow Step 2 Check refrigerant leakage Step 3 Check outdoor EEV operation Q3 Analysis Step 1 Contents While using cooling or heating System Turn off and display E458 Erro...

Страница 77: ...ontents While the system is working try run mode system turn off and display E128 129 246 261 419 422 554 Error code Check point Remarks These Error codes only apply with Try run mode in case of syste...

Страница 78: ...DF WBMVF PVU PG SBOHF JO UIF UFNQFSBUVSF UBCMF PO UIF SJHIU FT T JOEPPS UFNQFSBUVSF TFOTPS EJTDPOOFDUFE GSPN UIF DPOOFDUPS JO 1 3FTUBSU UIF TZTUFN BGUFS SFQMBDJOH UIF 1 3FTUBSU UIF TZTUFN BGUFS DPOOFD...

Страница 79: ...UIF NPUPS DPOOFDUPS EJTDPOOFDUFE GSPN UIF 1 3FQMBDF UIF 1 BOE SFTUBSU UIF VOJU POOFDU UIF DPOOFDUPS UP 1 BOE SFTUBSU UIF VOJU 3FNPWF UIF GPSFJHO TVCTUBODF BOE SFTUBSU UIF VOJU OEPPS VOJU EJTQMBZ 9 0Q...

Страница 80: ...F PWFS 7 BT TIPXO JO UIF GPMMPXJOH QJDUVSF IFDL UIF DPNNVOJDBUJPO DBCMF BOE SFQMBDF UIF JOEPPS VOJU 1 3FNPWF UIF DPNNVOJDBUJPO DBCMF DPOOFDUJOH UIF PVUEPPS VOJU UP JOEPPS VOJU BOE NFBTVSF UIF TJHOBM P...

Страница 81: ...FGSPTU 5JNFS 9 JMUFS 4ZNQUPN 130 DJSDVJU GBJMVSF BJMVSF 130 DPNQPOFOU GBJMVSF 130 DJSDVJU QBSUT NJTTJOH EBNBHFE TPMEFSJOH GBJMVSF P FT SF UIF 130 DJSDVJU DPNQPOFOUT JO HPPE DPOEJUJPOT NJTTJOH DPNQPOFO...

Страница 82: ...SJEHF EJPEF 7 FT 3FQMBDF UIF GVTF P T UIF GVTF DPOOFDUFE 3FQMBDF UIF JOWFSUFS 1 P T UIF SFTJTUBODF WBMVF PG 3 FT FT POOFDU UIF SFBDUPS P T UIF SFBDUPS DPOOFDUPS DPOOFDUFE DPSSFDUMZ 3FQMBDF UIF 1 4 5 2...

Страница 83: ...G UIF GBO 7_ 7 T UIF WPMUBHF CFUXFFO QJO BOE QJO PG UIF GBO EVSJOH UIF PQFSBUJPO 7_ 7 FT P FT FT IFDL 3FQMBDF UIF GBO NPUPS IFDL UIF PVUEPPS VOJU QPXFS TVQQMZ FSSPS 3FQMBDF UIF JOWFSUFS 1 3FQMBDF UIF...

Страница 84: ...F DPOOFDUFE UP UIF DPNQSFTTPS DPSSFDUMZ 4FSWJDF FOE 3FQMBDF UIF DPNQSFTTPS 3FQMBDF UIF DPNQSFTTPS IFDL UIF DPOOFDUJPO XJSF 4 5 4 Compressor startup error Compressor Lock error Compressor rotation erro...

Страница 85: ...DPSSFDUMZ P 3FNPWF UIF PCTUBDMFT BOE JOTUBMM UIF VOJU BHBJO FT T UIF TFSWJDF WBMWF DPNQMFUFMZ PQFO P 0QFO UIF WBMWF FT T UIF DPNQSFTTPS DPOOFDUJPO XJSF DPOOFDUFE UP UIF DPNQSFTTPS DPSSFDUMZ P IFDL UIF...

Страница 86: ...door unit temperature can be monitored with VIEW MODE Press K4 key on the outdoor display PCB for several time to change the display to sensor temperature value Left 1 digit of the LED is data index a...

Страница 87: ...up correct Yes Is the sensor resistance value 200kohm 3 at the room temperature of 25 No Sensor Replace Sensor resistance value 20 12 09kohm 30 8 31kohm 35 6 94kohm 40 5 83kohm Connect the sensor to...

Страница 88: ...adhere to the lead wires if not polished 6 When soldering any part care should be exercised not to apply any high wattage soldering iron to the part for a long time Some parts are of so low a heat res...

Страница 89: ...Indoor Fan TAP YW396 09AV WHT Temperature Sensor SMW250 02 YEL Ventilator YW396 03AV BLK Wired Remote Controller Power YW396 02 WHT Drain Pump YW396 03AV YEL External Control S W Part SMW250 02 RED H...

Страница 90: ...12V 2 4 6 GND 2 GND 2 5 LED control signal 3 EVA OUT temperture sensor 6 REMOCON signal out 5 EVA discharge 7 8 Not used 9 REMOCON_INT 10 GND 11 Vcc 9 VENT 10 Panel flaps 11 SPI 12 Drain Pump 1 DC12V...

Страница 91: ...Samsung Electronics 5 3 1 DC 12V 2 5 LED control signal 6 Remocon signal out 7 8 Not used 9 Remocon signal IN 10 GND 11 DC 5V CN01 DISPLAY 1 Q Panel PCB...

Страница 92: ...41 4 7 8 0 6 8 6 35 4 8 6 35 4 8 3 4 5 4 7 41 _ _ 0 08 5 1 3 563 4 403 300 4 403 7 4 403 7 4 403 0 6 5 0 0 4 0503 _ 7 7 31 4 _ _ 4 4 7 7 4 14 108 3 _ 7 4 14 065 7 7 7 7 4 14 065 7 7 7_ 7 7_ 7 08 0 08...

Страница 93: ...Samsung Electronics 5 5 5 2 Outdoor Unit Q AJ020JCJ2CH AJ024JCJ3CH 1 2 3 4 5 6 7 8 7 6 3 3 2 3 0 2 6 7 6 7 6 SIGNAL 6 3 0 2 53 6 6 6 6 54 3 3 2 5 ISPLAY 6 6 54 6 3 EGMENT 6 6 54 EY IN 6 54 6 RID 6 54...

Страница 94: ...8 OLP Temp 5 6 7 8 1 4 EEV signal 1 4 EEV signal 1 TXD 1 DC12V 5 DC 12V 5 DC 12V 2 RXD 2 GND 3 GND 4 DC 5V 5 DC 12V 6 INV SMPS signal 9 CN31 COMM 10 CN33 Sub Comm 11 12 1 COM1 1 DC12V 1 10 MICOM DOWN...

Страница 95: ...PS 8 5 3FBDUPS 3FBDUPS 39 59 7 7 7 4 14 TJHOBM 39 5 30 59 5 30 _ 5 TJHOBM 7 PS 4 8 FOHJOFFS EFCVHHJOH 7 7 31 31 GFFECBDL 7 7 31 31 GFFECBDL 0 1 6 QIBTF 3 0 1 7 QIBTF 6 0 1 6 QIBTF 3FBDUPS 3FBDUPS 1 3...

Страница 96: ...4 COM1 7 8 EVA IN D 5 COM2 9 10 EVA IN E 5 6 7 1 2 EVA OUT A 1 4 EEV signal 1 4 EEV signal 3 4 EVA OUT B 5 DC 12V 5 DC 12V 5 6 EVA OUT C 7 8 EVA OUT D 9 10 EVA OUT E CN33 Sub Comm CN10 MICOM DOWN CN1...

Страница 97: ...Samsung Electronics 6 1 6 Wiring Diagram 6 1 INDOOR UNIT Q AJ009JNNDCH AJ012JNNDCH AJ018JNNDCH This Document can not be used without Samsung s authorization...

Страница 98: ...6 2 Samsung Electronics Q AJ007JNADCH AJ009JNADCH AJ012JNADCH AJ018JNADCH AJ024JNADCH This Document can not be used without Samsung s authorization...

Страница 99: ...Samsung Electronics 6 3 Q AJ009JNLDCH AJ012JNLDCH AJ018JNLDCH This Document can not be used without Samsung s authorization...

Страница 100: ...6 4 Samsung Electronics 6 2 OUTDOOR UNIT Q AJ020JCJ2CH AJ024JCJ3CH...

Страница 101: ...Samsung Electronics 6 5 Q AJ036JCJ5CH...

Страница 102: ...6 6 Samsung Electronics MEMO...

Страница 103: ...Make sure that you install the indoor unit in an area away fromTVs audio units cordless phones fluorescent lighting fixtures and other electrical appliances at least 1 meter 6 Make sure that you inst...

Страница 104: ...connection within the maximum allowable length of a coolant pipe If you install within 50m no add a additional refrigerent This model is chargeless within 50m 8 Make sure that you install the outdoor...

Страница 105: ...about 30 minutes Close the valve of the low pressure side of manifold gauge clockwise Make sure that pressure gauge show 0 1MPa 76cmHg after about30 minutes This procedure is very important in order t...

Страница 106: ...way valve again 5 Check the pressure indicated by the pressure gauge low pressure side Standard pressure should be 8 0 9 0kg cm2 in a regular and high operation mode 6 Open the refrigerant tank and fi...

Страница 107: ...basic quality of Room Air conditioner for example cooling capacity sound level vibration level and reliability But according to a certain different installation condition the connection tube length co...

Страница 108: ...unit and the other pipe using a cap or vinyl plug to avoid foreign material entering 6 Make sure you do not bend the connection pipes in the middle and store together with the cables 7 Move the indoo...

Страница 109: ...115V 60hz 1 B B 220V 60Hz 1 C C 208 230V 60Hz D D 200 220V 50Hz E E 220 240V 50Hz F F 208 230V 60Hz 3 G G 380 415V 50Hz 3 H H 380V 60Hz 3 J J 460V 60Hz 3 K K 220 240V 50 60Hz 1 M M 127V 50Hz N N 380...

Страница 110: ...oltage Code Type A A 115V 60hz 1 B B 220V 60Hz 1 C C 208 230V 60Hz D D 200 220V 50Hz E E 220 240V 50Hz F F 208 230V 60Hz 3 G G 380 415V 50Hz 3 H H 380V 60Hz 3 J J 460V 60Hz 3 K K 220 240V 50 60Hz 1 M...

Страница 111: ...Samsung Electronics 7 9 AJ020JCJ2CH CYCLE DIAGRAM 7 8 Refrigerating Cycle Diagram AJ024JCJ3CH CYCLE DIAGRAM...

Страница 112: ...7 10 Samsung Electronics AJ036JCJ5CH CYCLE DIAGRAM...

Страница 113: ...ated technology words Definition of technology terms COMP Full name compressor BLOWER FAN ASS Y CONTROL BOX Full name Assemble control box MOTOR ASS Y EVAP ASS Y COND Full name assemble evaporator ass...

Страница 114: ...se select Cooling or set the desired temperature lower Q It floods the floor A Place the drain hose properly When it is not placed properly the drain water would flow back flooding the floor So straig...

Страница 115: ...kept without drying up the inside with Ventilation mold would grow inside resulting in must So open the windows and switch on the Ventilation function to get rid of the saturated smell inside Q Whene...

Страница 116: ...utdoor unit outside A It is possible to install it at a designated place in the apartment or on the rooftop nearby But it s illegal hanging an angle iron case with the outdoor unit in it outside the a...

Страница 117: ...should emit outside of the body by air circulation conduction emission and evaporation The human body feels freshness when the emission rate is 40 45 which was emitted by a radiation when it is comfo...

Страница 118: ...ual is a property of Samsung Electronics Co Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law Samsung Electronics Co Ltd 2014 Printed in China Code...

Отзывы: