Step 3 Optional: Insulating the body of
the indoor unit
"
$
#
%
Thickness: more than 0.39 inch (10 mm)
Indoor Unit
AJ***BNHDCH
33.46 x 27.56 x 9.84
(850 x 700 x 250)
A
33.46 x 27.56
(850 x 700)
B
33.46 x 27.56
(850 x 700)
C
27.56 x 9.84
(700 x 250)
D
27.56 x 9.84
(700 x 250)
Front/Back
Insulate the front and back side in proper size
at the same time when insulating the suction
duct and discharge duct.
Unit : inch (mm)
NOTE
• Insulate the end of the pipe and some curved area by using
separate insulator.
• Insulate the discharge and suction part at the same time
when you insulate connection duct.
Step 4 Installing the indoor unit
When deciding on the location of the air conditioner with the
owner, the following restrictions must be taken into account
1
Place the pattern sheet on the ceiling at the spot where you want
to install the indoor unit.
NOTE
• Since the diagram is made of paper, it may shrink or stretch
slightly due to temperature or humidity. For this reason,
before drilling the holes maintain the correct dimensions
between the markings.
2
Insert bolt anchors. Use existing ceiling supports or construct a
suitable support as shown in figure.
Concrete
Suspension bolt (M8) - field supply
Insert
Hole in anchor
Hole in plug
Front
Back