24
Installation Procedure
Installation Pr
oc
edur
e
English
2
Press the
/
button to select and then press
button to enter a Sub-menu setting screen.
3
Press the
/
button to select and then press
button to enter a Indoor Address setting screen.
1 2 3 4
5 6
Data bit
NOTE
• The Main/RMC Address which is currently setting will flicker.
• Data bit 1 and 2 present Indoor unit main address checking
• Data bit 3 and 4 present Indoor unit main address
setting(outdoor unit reset is needed to set).
• Data bit 5 and 6 present Indoor unit RMC address setting/
checking.
4
Press the
/
button to set the Indoor unit Main/RMC
Address.(Refer to the Indoor Unit Address Options table on page
31)
5
Press the
button to save and complete the option setting.
6
Press the
button to exit to normal mode.
NOTE
• Press
the
button anytime during setup to exit without
setting.
• Address will not be applied if you don't press
button.
• Setting Main/RMC Address of an Indoor unit is available only
with a Main wired remote controller.
Setting an indoor unit installation option
In order to check and set the indoor unit installation option code
use the wired remote controller and follow the directions below.
1
Press the
and
buttons at the same time for more than 3
seconds and then a Main menu will be displayed.
2
Press the
/
button to select and then press
button to enter a Sub-menu setting screen.
3
Press the
/
button to select and then press
button to enter a Indoor unit installation option code setting
screen.
NOTE
• The first digit represents the page number and the remaining
five digits are installation option.
• The total option codes are 24 digits. You can set six digits at a
time and it is distinguished by page number (0, 1, 2, 3).
4
Press the
/
button to set the installation option code
in order. Press
button to go to the next page.(Refer to the
Indoor Unit Install Options table on page 32)
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
0
2
RESERVED
Exterior
temperature
sensor
Central
control
RESERVED
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
1
Drain pump
Hot Coil
Auxiliary
heater
Controller
variables
for auxiliary
heater
RESERVED
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
2
External
control
External
control
output
RESERVED
Buzzer
Maximum
filter usage
time
SEG19
SEG20
SEG21
SEG22
SEG23
SEG24
3
Individual
control of
a remote
controller
Heating
setting
compensation
RESERVED
Away Set
OFF Timer
RESERVED
5
Press the
button to save and complete the option setting.
6
Press the
button to exit to normal mode.
NOTE
• Press
button anytime during setup to exit without
setting.
• Option code will not be applied if you don't press
button.
• Setting Installation option code is available only with a Main
wired remote controller.
• Setting Installation option code is available when there is one
on one connection between a wired remote controller and an
indoor unit.
Содержание AJ BNHDCH Series