49
ENGLISH
Dimension and weight
Type
Model
Net dimension (WxDxH) (mm)
Net weight(kg)
Outdoor Unit
AC026HCADKH
720*265*548
29.5
AC035HCADKH
720*265*548
29.5
AC052HCADKH
880*310*638
45.0
AC060HCADKH
880*310*793
55.0
AC071HCADKH
880*310*793
55.0
AC052HCAPKH
880*310*793
54.0
Model specification (Dimension and weight)
Appendix
No.
Meaning
Remarks
Error Code
29 EEV or Valve Close error-Self diagnosis
1. Check if the service valve is open
2. Check for refrigerant leakage (pipe connections,
heat exchanger) and charge refrigerant if
necessary
3. Check if there's any blockage on refrigerant
cycle (indoor unit/outdoor unit)
4. Check if additional refrigerant has been added
after pipe extension
E422
30 Outdoor EEPROM checksum error between MAIN and INVERTER. Check Outdoor Inverter PBA
E590