Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can
be operated within.
Refer to the table for efficient use.
• The standardized temperature for heating is 7˚C/45˚F. If the outdoor temperature drops to 0˚C/32˚F or below, the
heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C/90˚F (indoor temperature), it does not cool at its full capacity.
NOTE
• The use of the air conditioner at a relative humidity above the expected one (80%)
may cause the formation of condensate and the leakage of water drops on the
floor.
CAUTION
MODE
OUTDOOR TEMPERATURE
INDOOR TEMPERATURE
INDOOR HUMIDITY
COOLING
2.6kW
-10°C/14°F to 46°C/115°F
18°C/64°F to 32°C/90°F
80% or less
3.5kW
5.2kW
6.0kW
-15°C/5°F to 46°C/115°F
7.1kW
-15°C/5°F to 50°C/122°F
HEATING
2.6kW
-15°C/5°F to 24°C/75°F
27°C/81°F to less
3.5kW
5.2kW
6.0kW
-20°C/-4°F to 24°C/75°F
7.1kW
DRYING
2.6kW
-10°C/14°F to 46°C/115°F
18°C/64°F to 32°C/90°F
3.5kW
5.2kW
6.0kW
-15°C/5°F to 46°C/115°F
7.1kW
-15°C/5°F to 50°C/122°F
Mode
Outdoor temperature
Indoor
temperature
Indoor humidity
If out of conditions
Cooling
-5˚C/23˚F ~46˚C/115˚F 16˚C/61˚F~32˚C/90˚F
80% or less
Condensation may occur on the indoor
unit with risk to have either water blow
off or drop on the floor.
Heating
-15˚C/5˚F~24˚C/75˚F
27˚C/81˚F or less
-
Internal protection triggers and the air
conditioner will stop.
Dry
-5˚C/23˚F~46˚C/115˚F 18˚C/64˚F~32˚C/90˚F
-
Condensation may occur on the indoor
unit with risk to have either water blow
off or drop on the floor.
Model : AJ