Frost & De-ice
• When the air conditioner runs in Heat mode, due to temperature
difference between the unit and the outside air, frost will form.
If this happens:
- The air conditioner stops heating.
- The air conditioner will operate automatically in De-ice mode for 10
minutes.
- The steam produced on the outdoor unit in De-ice mode is safe.
No intervention is required; after about 10 minutes, the air conditioner
operates again normally.
The unit will not operate when it starts to de-ice.
Fan
• Fan may not operate for about 3~5 minutes at the beginning to
prevent any cold blasts while the air conditioner is warming up.
High indoor/
outdoor
temperatures
• If both indoor and outdoor temperatures are high and the air
conditioner is running in Heat mode, the outdoor unit’s fan and
compressor may stop at times. This is normal; wait until the air
conditioner turns on again.
Power failure
• If a power failure occurs during the operation of the air conditioner,
the operating immediately stops and unit will be off. When power
returns, the air conditioner will run automatically.
Protection
mechanism
• If the air conditioner has just been turned on after operation stops or
power being supplied, cool/warm air does not come out for 3 minutes
to protect the compressor of the outdoor unit.
Automatic air
flow blade
control
• If the air conditioner is operating in abnormal conditions (such as
operating the air conditioner with windows open or when small
capacity indoor unit is installed and operating in a room that is too
large) indoor can become very humid when the angle of the air flow
blade is small and performance of the product may decrease. When
indoor humidity increases, indoor unit will automatically detect it and
open the air flow blade in wider angle to make sure that performance
of the product is stable.