20
Installation Procedure
Ins
tallation Pr
oc
edur
e
English
6
Apply heat to the contraction tube to contract it.
Contraction tube
Contraction tube
Method 1
Method 2
7
After tube contraction work is completed, wrap it with
the insulation tape to finish.
Three or more layers of insulation are required.
Insulation tape
Insulation tape
Method 1
Method 2
CAUTION
• Make sure that the connection parts are not exposed
to outside.
• Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials that
have the same level of withstand voltage with the
power cable. (Comply with the local regulations on
extensions.)
WARNING
• In case of extending the electric wire, please DO NOT
use a round-shaped Pressing socket.
–
Incomplete wire connections can cause electric
shock or a fire.
Step 15 Setting the indoor unit
addresses and the installation options
You cannot set both of the indoor unit addresses and
the installation options in a batch: set both of them
respectively.
Common steps for setting the addresses and
options
AR-KH00E/AR-KH03E remote control (for 360 cassette
only)
Temperature
button
Timer button
Wheel
Mode button
Setting the
option values
Entering the
mode for setting
the options
NOTE
• The remote control display may vary depending on
the model.
1
Enter the mode for setting the options:
a
Remove the batteries from the remote control.
b
While holding down the
(Temp) and
(Timer) buttons simultaneously, insert the
batteries into the remote control.
c
Make sure that you are entered to the mode for
setting the options:
CAC_R32_호주향 360 IM_EN_DB68-08492A-01.indb 20
2019-08-27 오후 3:49:13