background image

9

Designing an Installation Plan

Using A Constant Voltage Speaker System - continued

The same principle is applied in constant voltage 
audio systems where a transformer is connected to the 
amplifier’s output to step up the voltage while lowering 
the output current, which allows you to use long runs of 
lower gauge wire to connect to a series of speakers with 
step down transformers. For further cost savings, the 70 
volt standard was adopted in the US since UL requires 
the use of conduit on line over 100 volts peak. In addition 
to 70 volt operation, the SZ series amplifiers can also 
operate 100 volt systems which is a standard in Europe. 
Commercial sound systems, like those installed in schools, 
office building and restaurants commonly make use of 
constant voltage distributed sound systems when a large 
number of ceiling speakers are used to cover several 
different sound zones.
Today, there are a large number of installation speakers 
available from various manufacturers that include 
onboard transformers for constant voltage systems. 
Many of these models, like the Samson dB300i, include 
selectable power taps on the transformer allowing you 
to distribute the power efficiently through the number 
of installed speakers and also adjust some speakers to 
different output levels. The SZ series amplifiers have built 
in transformers on each channel that step up the output 
voltage and reduce the current allowing you to connect 
to a series of speakers with step down transformers over 
long cable runs. Constant voltage systems can use 14 to 
18 gauge wire, with smaller gauge (larger diameter) cable 
should be used for longer runs.
A simple way to think about using constant voltage is to 
divide the total watts available by the number of speakers 
you want to use. You could also add up the speaker's step 
up transformer wattage to equal 100 watts or less.  For 
example, if you want to use ten ceiling speakers on one 
channel of the SZ amplifier, use a ceiling speaker with a 
12-watt transformer tap (120 watts divided by 10 speakers 
equals 12-watts per speaker).

Typical ceiling speaker with onboard transformer and six 
power taps. These power taps also control volume level for 
sound balancing. 

Another example is connecting four of the Samson 
dB300i with the transformers wired for 25 watts to 
each channel of the SZ series amplifier.

Following the wiring diagram on the rear of the 
dB300i, connect the ground to Common, the Hot lead 
to 70 volt input, and finally, run a jumper from 8 ohms 
to the 25 watt connection as shown in the diagram 
below.  

Set up each of the dB300i they same way so that the 
four connected speakers equal 100 watts.

The dB300i's rear panel is configured for 70 volt 25 watt 
operation.

Now connect the four speakers to each of the SZ240’s 
output as shown in the diagram below.  

Zone 2

Zone 2

Содержание SZ240

Страница 1: ...SZ240 SZ480 POWER AMPLIFERS SZ SERIES...

Страница 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Страница 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Страница 4: ...Z Series Features 2 SZ480 Layout Front Panel 3 SZ480 Layout Rear Panel 4 SZ240 Layout Front Panel 5 SZ240 Layout Rear Panel 6 Designing an Installation Plan 7 Setting Up and Using Your SZ Series 10 Th...

Страница 5: ...ch rack mount design and convenient carry handles facilitating easy installation in any rack Optimized for commercial installations houses of worship live sound venues and for driving small and medium...

Страница 6: ...B crosstalk of 80 dB and frequency response of 10 Hz to 25 kHz guarantee ultra clean sound quality LED signal indicators for each channel continuously display power output levels and allow you to corr...

Страница 7: ...f When lit no signal is provided to any connected speakers thus muting them and preventing any thump from occurring For a complete description of the conditions under which this light goes on see the...

Страница 8: ...terconnection instructions 3 Limiter Each amplifier channel has a quick attack Limiter with peak detection to help ensure a clean signal The Limiter for each individual channel can be set to on or off...

Страница 9: ...s whenever the channel is outputting signal at full strength For the best signal to noise ratio the right PEAK segment should light occasionally during peak levels if it lights frequently you may be o...

Страница 10: ...nterconnection instructions 3 Limiter Each amplifier channel has a quick attack Limiter with peak detection to help ensure a clean signal The Limiter for each individual channel can be set to on or of...

Страница 11: ...onnect line level signals on all four input channels so signals from TAPE CD DVD or Karaoke players Audio Video TV monitors Radio Tuners DJ mixers or any other line level device can be used as a sound...

Страница 12: ...some time to consider where you need to have sound in your particular installation After you have decided where you need to create sound zones you can consider your speaker selection but first decide...

Страница 13: ...iers have built in transformers on each channel that step up the output voltage and reduce the current allowing you to connect to a series of speakers with step down transformers over long cable runs...

Страница 14: ...xt make the signal input connections using the Euroblock input connectors on the rear panel If your mixer has balanced outputs we recommend the use of three conductor cabling and connectors unbalanced...

Страница 15: ...s and that both the front and rear panels are unobstructed Severe over current conditions This occurs whenever the signal being input to the SZ Series rises to a level above 20 THD Total Harmonic Dist...

Страница 16: ...and 70 Volt operation SZ Series Connections 8 Ohm Operation One 8 Ohm speaker per amplifer 8 Ohm 8 Ohm 8 Ohm 8 Ohm 4 Ohm 4 Ohm 4 Ohm 4 Ohm 4 Ohm Operation Two 8 Ohm speakers per amplifer 70 Volt Opera...

Страница 17: ...first two SZ amp channels are connected to four wall mounted speakers in each of the Dining Rooms with their transformers set to a 25 watt tap The third SZ amp channel powers two speakers in the outs...

Страница 18: ...ways to interface the SZ series amplifers depending on your exact system set up Follow the cable diagrams below for connecting to the input of your amplifier Euroblock to RCA Unbalanced Euroblock to 1...

Страница 19: ...e zip cord can be used for most small to medium size installations Follow the cable dia grams below for connecting to the input of your amplifier 4 and 8 Ohm Wiring Guide 70 Volt Wiring Guide 100 Volt...

Страница 20: ...d cooling through your SZ Series amplifier To clean the fan filters follow these simple steps 1 Remove the fan filter by placing your finger in the depressed area under the fan filter frame 2 Clean th...

Страница 21: ...channel Input Active balanced Euroblock Output Euroblock Controls AC power switch Channel volume Limiter Indicators Power on blue Protection amber Signal green for each Ch Peak red for each Ch Protect...

Страница 22: ...18 Block Diagram...

Страница 23: ......

Страница 24: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Отзывы: