Samson SERVO 200 Скачать руководство пользователя страница 8

6

Setting Up and Using Your Servo Series

Bridge / Stereo  switch

Output connectors

Input connectors

Protection LED

Channel Input control

Three-segment LED meter

Setting up your Servo Series is a simple procedure which takes only a few minutes:

1.  Remove all packing materials (save them in case of need for future service) and decide where the 
amplifier is to be physically placed—it can be used free-standing or mounted in a standard 19” rack, 
requiring only two rack spaces.  When installed, make sure that both the front and rear panels are 
unobstructed and that there is good  ventilation around the entire unit (we recommend the use of 
spacer panels, especially if  multiple amplifiers are used in a rack.)

2.  Set the rear panel Bridge/ Stereo switch as desired (see the “Bridge Mode” section on page 8 in this 
manual for more information).

3.  Make the speaker connections, using the banana or 1/4-inch output connectors on the rear panel.  
It is never a good idea to power up any amplifier that is not connected to loudspeakers.  When oper-
ating in Stereo mode, any loudspeakers with a  minimum impedance load of 4 ohms (that is, 4 ohms 
or greater) can be used; however, in Bridged mode, 16 or 8 ohm speakers must be used.  Be sure to 
connect the loudspeaker correctly.  In Stereo mode, make sure the red (+) terminal is connected to 
the positive input of the speaker and the black (ground) terminal is connected to the negative input 
of the speaker. See page 8 in this manual for more information about Bridged mode and page 9 in 
this manual for full speaker interconnection instructions.

4.  Next, make the signal input connections, using the RCA or 1/4-inch input connectors on the rear 
panel (if operating the Servo Series in Bridged mode, use the Channel 1 input only—see page 8 in 
this manual for more information).  If your mixer or crossover network has balanced outputs, we rec-
ommend the use of three-conductor cabling and connectors (unbalanced two-conductor plugs can 
also be inserted into the 1/4-inch inputs, but you’ll get better signal quality and less outside noise 
and hum if you use balanced lines).

5.  On the front panel of the Servo Series, turn both Channel input controls fully  counterclockwise (to 
their “MIN” setting).  Then connect the supplied heavy-gauge 3-pin “IEC” cable to the rear panel IEC 
connector and to any grounded AC socket.  

Because of the relay protection circuitry built into the Servo Series, you can even plug it into the 
same power strip that other audio devices (such as a mixing console) are connected to.  You can then 
turn on all devices at once with the single power strip on-off switch, with no danger of damaging 
connected speakers by generating “thumps.”

6.  Press the front panel Power switch in order to turn on the Servo Series.  The Power LED will light 
and the Protection LED will go on.  After approximately five seconds, the Protection LED will go off 
(you’ll hear a click when this occurs).

7.  Apply an input signal to the Servo Series at or about +4dBu (if sending signal from a mixer, drive 
the output meters at approximately 0 vu).  While the input signal is present, slowly raise the Channel 
Input controls until the desired sound level is achieved.  The SIGNAL and PEAK LED indicators next to 
each Channel input control will show you the  continuous power output of the Servo Series as signal 
is being passed.  For the best signal-to-noise ratio, the Servo Series should normally be run with the 
Channel Input controls at or near maximum (fully clockwise, at the “MAX” position) and the PEAK 
segments should light occasionally (but not frequently) during peak levels.  If you are using a mixer 
that has a master output level control (sometimes called “control room level”), use it to attenuate the 
signal as necessary to achieve the desired speaker level.

If you encounter difficulty with any aspect of setting up or using your Servo Series,  contact your lo-
cal Samson dealer.  If purchased in the United States, you can call Samson Technical Support (1-800-
372-6766) between 9 AM and 5 PM EST

Содержание SERVO 200

Страница 1: ...SERVO 200 00 SERVO 300 SERVO 300 SERVO 300 SERVO 300 SERVO 300 SERVO 300 SERVO 600 SERVO 600 SERVO 600 SERVO 600 SERVO 600 SERVO 600...

Страница 2: ...r objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita qu...

Страница 3: ...3 SAMSON 1 800 372 6766 Fax 516 364 3888 Table of Contents Introduction 2 Servo Series Features 3 Guided Tour 4 5 Front Panel 4 Rear Panel 5 Setting Up and Using Your Servo Series 6 The Servo Series...

Страница 4: ...n LED indicators There s also a Protection LED indicators There s also a ten segment Level VU meter to help you set a good operating level Like all serious power amplifiers the Servo Series internal e...

Страница 5: ...This serves to minimize heat overload problems by effectively preventing the Servo Series from applying power when unnecessary Forced air cooling via two temperature sensitive variable speed fans pro...

Страница 6: ...g output If this occurs and backing off the Input Level control delivers too low an output level for your application consider using Bridged mode see the Bridged Mode section on page 8 in this manual...

Страница 7: ...e page 8 in this manual for more information about Bridge mode and page 9 in this manual for full speaker connection instructions 5 1 4 inch Input Connectors Connect incoming signals to these electron...

Страница 8: ...bling and connectors unbalanced two conductor plugs can also be inserted into the 1 4 inch inputs but you ll get better signal quality and less outside noise and hum if you use balanced lines 5 On the...

Страница 9: ...d that both the front and rear panels are unobstructed Severe overcurrent conditions This occurs whenever the signal being output from the Servo Series rises to a level above 20 THD Total Harmonic Dis...

Страница 10: ...h the speaker load connected so that power is derived from both channels The effective voltage swing seen by the load is thus doubled so that the power output is multiplied by more than two When using...

Страница 11: ...nnections when using the Servo Series in Stereo and Bridged modes Servo Series Connections 9 4 ohm min 4 ohm min 4 ohm min 4 ohm min 8 ohm min 8 ohm min 8 ohm min 8 ohm min MPL2242 MMPL2242 Stereo Mod...

Страница 12: ...3dB 5Hz 60kHz Frequency Response 8ohms 1Watt 0 0 5dB 20Hz 20kHz 0 3dB 5Hz 60kHz Damping Factor 400Hz 280 280 350 Damping Factor 400Hz 280 280 350 Damping Factor 400Hz 280 280 350 Input Impedance 15koh...

Страница 13: ...5 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 0 5 0 55 0 6 0 65 0 7 0 75 0 8 0 85 0 9 0 95 0 125 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 10 50k 20 50 100 200 500 1k 2k 5k 1...

Страница 14: ...nse Linearity 0 dB Ref vs Frequency sweep 10 Hz 50 kHz Typical for all Servo models 5 0000 4 0000 3 0000 2 0000 1 0000 0 0 1 000 2 000 3 000 4 000 5 000 10 100 1k 10k 50k Ap AUDIO PRECISION Servo 600...

Страница 15: ......

Страница 16: ...Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 www samsontech com...

Отзывы: