background image

DIGITAL DUAL 31 BAND EQUALIZATION SYSTEM

Содержание D-2500

Страница 1: ...DIGITAL DUAL 31 BAND EQUALIZATION SYSTEM...

Страница 2: ...r objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita qu...

Страница 3: ...D2500 Faders 11 Using the Process Switches 12 Using the EQ section 12 Using the FEEDBACK Management Function 12 Using the Internal Noise GATE 13 Using the Internal DELAY 13 Setting up and Using the Hi...

Страница 4: ...n 99 pre set locations Using the large easy to read LCD display and conve nient data wheel it s possible to save your favorite equalization curves and recall them in the future Or when using the D2500...

Страница 5: ...and suppression Manual or Auto mode with Automated Filter Restoration The D2500 s fader can be set for either 3 6 or 12 dB of gain and attenuation for each of the frequency bands An onboard programmab...

Страница 6: ...alizer to the physical controls 10 LINK switch Used to control the left and right CH1 and CH2 equalizer simultaneously with the one set of physi cal controls Controls and Functions Front Panel Layout...

Страница 7: ...Electronically balanced XLR jack output 19 LIMITER switch This switch is used to page through the LIMITER parameters When selected the amber LED will illuminate and the LIMITER parameters will be disp...

Страница 8: ...NG UP THE D2500 to work in MANUAL mode The D2500 is simple to use In fact you can use it just like a standard analog graphic equalizer by simply set ting the unit to MANUAL mode Setting up your D2500...

Страница 9: ...lizer D2500 Quick Start 7 12 Apply an input signal to the D2500 if sending signal from a mixer output bus drive the mixer s output meters at approximately 0 VU While the input signal is present slowly...

Страница 10: ...The D2500 function switch sections are arranged on the front panel as follows First is the BYPASS switch that enables you to turn the equalizer and all effects on or off Next is the A B switch that l...

Страница 11: ...dwidth for either 1 4 1 3 1 2 of an octave or to AUTO which will allow each of the 31 filters to be set to an individual bandwidth calculated by the onboard DSP To access the Filter band width setting...

Страница 12: ...and control either one or both sides The state of these switches will determine which of the left and right signals are affected by the hardware control surface Using the LINK switch If you want to s...

Страница 13: ...loading in preset 00 If you are not very familiar with working with the presets just stay on preset 00 Preset 00 can not be overwritten so don t worry about erasing anything Press the MANUAL button to...

Страница 14: ...zer filters as well as the Master Fader filters are displayed in the LCD window You can use the Data Wheel to scroll through the frequencies and display the filter levels in the main LCD window It is...

Страница 15: ...al rises above the Threshold level The Noise Gate Switch Has Two Clicks Click Menu Function Value 1 Gate Rel Release Time 50 100 2 Gate Th Threshold Level 0 100 dB To operate the D2500 digital noise G...

Страница 16: ...your system When equal izing a monitor system you may use both the HP and LP filters to roll off the high and lows for a vocal eq contour Any good high and low pass filter will allow you to choose the...

Страница 17: ...set from 50 to 100 which is the equivalent to 2 to 15 seconds Using the A B Feature The A B switch lets you compare the actual modified program to the last program recalled or stored in memory After...

Страница 18: ...tion go on to the next step If you want to choose a new memory location use the Data Wheel to scroll through the 99 preset num bers until you reach the number you want to recall into memory Once you s...

Страница 19: ...hese modes and their associated parameters Setting the D2500 to Transmit and Receive MIDI To enable the D2500 to send and receive MIDI data follow these steps Press the MIDI switch until that LCD read...

Страница 20: ...l to select SysEx T R Use the Data Wheel to select SysEx OFF and the D2500 will not transmit or receive any system exclusive mes sages To keep the new changes press the STORE button and you will exit...

Страница 21: ...e or for any EQ response curve that you may have saved in memory THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES CLASS B OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MUST NOT...

Страница 22: ...ORE NOTE You may need to come back to this to make the final mic gain adjustment once you start generating the PINK NOISE at the desired operating level AUTO EQ YOUR SYSTEM Once you have the Mic Input...

Страница 23: ...reads F R Now turn the Data Wheel until the dispay reads 12 dB Press the D2500 s Global switch a few times until the display reads F Bw Then turn the Data Wheel until the display reads 1 3 Oct Press...

Страница 24: ...ting the D2500 with the D1500 RTA Press RES and use the Data Wheel to select 2 0 dB which will correspond to the D2500 provided that the Frequency Range Global Menu of the D2500 is set to the default...

Страница 25: ...wise until the LED indicators are oper ating in a range approximately halfway up the display Operating the D2500 with the D1500 RTA Operating the D2500 with the D1500 RTA Using the signal Generator Th...

Страница 26: ...outputs are connected to the inputs of each active self powered loudspeaker Using the D2500 with Passive Speakers In this example the mixer s stereo output is connected to the D2500 s inputs Then the...

Страница 27: ...n D2500 is used for both the main PA speakers running a mono mix and for the monitor mix also in mono For the main PA the mixer s MONO output is connected to the D2500 s Channel 1 input Then the D2500...

Страница 28: ...peakers Then the outputs are connected to the inputs of the power amplifier connected to passive loudspeakers For the monitor mix the mixer s AUX1 output is connected to the second D2500 s channel 1 i...

Страница 29: ...g set up Follow the cable diagrams below for connecting your monitor system 27 XLR Insert Cable Balanced 1 4 to FEMALE XLR Cable Unbalanced XLR to 1 4 Cable Balanced MALE XLR to 1 4 Cable Unbalanced M...

Страница 30: ...p 4 dBu 1 kHz unity gain Digital Processing Converter 24 bit Delta Sigma 64 128 oversampling Sample rate AIO1 AIO2 32 44 1 48 64 88 2 96 kHz DIO1 96 kHzType digital 31 band equalizer DIO1 96 kHzType d...

Страница 31: ......

Страница 32: ...Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 www samsontech com...

Отзывы: