background image

If you’ve had some prior experience using wireless systems, these QuickStart 

instructions will get you up and running with your AirLine Synth UHF guitar system in 

a matter of minutes!  Detailed instructions for setting up and using your AirLine Synth 

system can be found on page 15 of this manual, and the “Guided Tour” sections on 

pages 4 - 11 provide full descriptions of all AirLine component controls and displays.

1.   Unpack the AR300 receiver and AG300 

transmitter and configure the AG300 for 

Fender Strat™ or flat jack style guitars. 

If you need to change the phone plug 

configuration, simply remove the 

thumbscrew, unscrew the plug and 

reinstall the two components while 

swapping their positions.

2.   Physically place the AR300 receiver on your 

amp or in front of you. Extend its antennas 

vertically and spread the tips horizontally 

outwards.

3.   Set the power switch on your AG300 

transmitter to the “off” position (away from 

the arrow) and place a fresh AA battery 

in it.  Then turn the transmitter back on 

momentarily; its LED will flash once and then go off if the battery is sufficiently 

strong.  Once battery strength is verified, turn the transmitter off again, then put it 

aside for now.

4.   Connect the included AC power supply to the rear of the AR300 and then to an 

available wall socket.  Turn the AR300 on momentarily to confirm that the unit has 

power. Then turn the AR300 power off.

5.   Turn your amplifier or mixer off and make the physical cable connection between 

an audio input and the AR300 output jack.

6.   Turn the Level knob on the AR300 completely counterclockwise, then turn its 

power on.

QuickStart

2

Содержание AG300

Страница 1: ...WIRELESS GUITAR SYSTEM...

Страница 2: ...t produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third g...

Страница 3: ...die Gefahr eines Stromschlags zu verringern sollten Sie weder Deckel noch R ckwand des Ger ts entfernen Im Innern befinden sich keine Teile die vom Anwender gewartet werden k nnen berlassen Sie die W...

Страница 4: ...o la humedad si no funciona normalmente o si ha ca do al suelo ATTENZIONE per ridurre il rischio di incendio o di scariche elettriche non esponete questo apparecchio a pioggia o umidit Per ridurre il...

Страница 5: ...ight 2008 Samson Technologies Corp Printed December 2008 v1 2 Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontec...

Страница 6: ...ickStart 2 QuickStart 3 Guided Tour AR300 Receiver Front Panel 4 5 Guided Tour AR300 Receiver Rear Panel 6 Guided Tour AG300 Transmitter 7 8 Setting Up and Using Your AirLine Synth System 9 11 AR300 O...

Страница 7: ...it the audience in the middle of your performance It operates in the UHF frequency range and contains an AR300 half rack receiver and the AG300 plug in micro transmitter designed to fit the recessed s...

Страница 8: ...ysically place the AR300 receiver on your amp or in front of you Extend its antennas vertically and spread the tips horizontally outwards 3 Set the power switch on your AG300 transmitter to the off po...

Страница 9: ...al performance level while observing the AF Meter If the AF Meter reads above 0 indicating a Peak condition even with the AR300 Level control fully counterclockwise engage the 15 dB pad on the transmi...

Страница 10: ...can be adjusted using the supplied plastic screwdriver it should normally be left at its factory setting See the Setting Up and Using the AirLine Synth System section on page 15 in this manual for mo...

Страница 11: ...Meter 10 segment bar meter used to display the level of the radio frequency reception 10 LCD Display The 47mm x 17mm backlit display show information for Frequency Channel Group Absolute Channel Annt...

Страница 12: ...r to line level equipment The output connection can be either balanced or unbalanced Wiring is as follows tip hot ring cold sleeve ground D XLR output Use this electronically balanced low impedance 60...

Страница 13: ...battery is a good operating level The LED lights steadily red when there are less than 2 hours of battery power remaining indicating that the battery needs to be changed In order to avoid compromising...

Страница 14: ...d will void your warranty 9 15 dB Pad Located under the battery is a miniature slide switch to adjust the AG300 s input sensitivity Move this switch in the direction of the arrow to reduce the output...

Страница 15: ...is also to ON Pull back gently on the AG300 battery cover at the ribbing and pry it upwards to remove it Please use care when opening this cover as undue force can damage it Install a fresh AA alkalin...

Страница 16: ...e output level of your electric guitar or bass to maximum and begin playing it at a normal performance level while observing the AR300 AF Meter If all the bars are lit indicating a Peak condition even...

Страница 17: ...l range available 14 When first setting up your AirLine Synth system in a new environment it s always a good idea to do a walkaround in order to make sure that coverage is provided for your entire per...

Страница 18: ...ion the AG300 will also display the Absolute Channel number briefly when the power is shut off 1 Press the EDIT control once and you will see the Group and Group Channel Number Flash 2 Turn the EDIT c...

Страница 19: ...mation over infrared transmission 5 Now position the transmitter about 6 inches from the front of the AR300 with the AG300 IR receiver facing the AR300 s LCD display and turn the power on You will now...

Страница 20: ...lter Output 1 4 inch and XLR Balanced LCD Display 47mm x 17mm Back Lighted Display Frequency Channel Group Absolute Channel Anntena AF RF Scan IR Set Controls EDIT Encoder Button Volume Squelch Operat...

Страница 21: ...LED Interface Infrared Impedance 2 2k ohms Battery AA x 1 Current Consumption Less than 120mA Operating Voltage 1 2V 1 5V Battery Life 10 hours 25 C Operating Temperature 0 C 50 C RF Output Power 10m...

Страница 22: ...1 this device may not cause harmful interference and 2 this device must accept any interference received includ ing interference that may cause Undesired operation AirLine Synth UHF Wireless Micropho...

Страница 23: ......

Страница 24: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Отзывы: