background image

6.    Make the physical cable connection between the AR300 output jack and an audio 

input of your amplifier or mixer.  Leave your amplifier or mixer off at this time.

7.     Turn the Level knob on the AR300 completely counterclockwise, then set its Power 

switch up to turn it on.  The LCD display light will illuminate.

8.    Now to set the channel, press and hold the EDIT control until the display reads CH 

SCAN. Next, the AR300 will automatically find the clearest channel and you will see 

it in the Channel number of the display just before the IR SET will begin.

9.    Once you see the IR SET flashing in the LCD display, hold the transmitter, with the 

control switches facing you, approximately 6 inches away from the receiver and 

turn the AG300 power switch on. The AR300 will transmit the channel number to 

AG300 over infrared light and you will see the corresponding absolute channel 

number in the transmitter LCD.

10.  The RF Meter on the AR300 receiver should now be active, indicating that it is 

receiving valid RF signal and is placed and positioned correctly.

11.  Now it’s time to set the audio levels.  Turn on your amplifier and/or mixer but keep 

its volume all the way down.  Set the output level of your electric guitar or bass 

to maximum and begin playing it at a normal performance level while observing 

the AR300 AF Meter.  If all the bars are lit, indicating a Peak condition, even with 

the AR300 Level control fully counterclockwise, engage the 15 dB pad on your 

transmitter by sliding the switch in the direction of the arrow.  (In general, if you 

have single coil pick-ups, you’ll probably want set the PAD to “OFF”.  If you have 

supper hot humbuckers, you’ll probably want to switch the PAD on.) If the AF Meter 

bars are not all lit, slowly turn the AG300’s Gain control clockwise to the point 

where the AF Meter reaches ‘‘0” during the very loudest passages, then back it off 

just slightly; this will ensure maximum signal to noise ratio.  Now, raise the Level on 

the AR300. Finally, raise the level of your amplifier and/or mixer until the desired 

volume  is reached.

12.  If you hear distortion or the AR300  AF Meter is reaching “0”  with the 15 dB pad 

engaged and the TX Gain control at minimum (fully counterclockwise), reduce the 

output level of your instrument until AF Meter is reading less than “0”.  Conversely, 

if you hear a weak, noisy signal at the desired volume level, make sure that your 

instrument is set to maximum output level, that the 15 dB pad is not engaged, and 

that the AG300 Gain control is turned up.  

Setting Up and Using Your AirLine Synth System

10

Содержание AG300

Страница 1: ...WIRELESS GUITAR SYSTEM...

Страница 2: ...t produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third g...

Страница 3: ...die Gefahr eines Stromschlags zu verringern sollten Sie weder Deckel noch R ckwand des Ger ts entfernen Im Innern befinden sich keine Teile die vom Anwender gewartet werden k nnen berlassen Sie die W...

Страница 4: ...o la humedad si no funciona normalmente o si ha ca do al suelo ATTENZIONE per ridurre il rischio di incendio o di scariche elettriche non esponete questo apparecchio a pioggia o umidit Per ridurre il...

Страница 5: ...ight 2008 Samson Technologies Corp Printed December 2008 v1 2 Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontec...

Страница 6: ...ickStart 2 QuickStart 3 Guided Tour AR300 Receiver Front Panel 4 5 Guided Tour AR300 Receiver Rear Panel 6 Guided Tour AG300 Transmitter 7 8 Setting Up and Using Your AirLine Synth System 9 11 AR300 O...

Страница 7: ...it the audience in the middle of your performance It operates in the UHF frequency range and contains an AR300 half rack receiver and the AG300 plug in micro transmitter designed to fit the recessed s...

Страница 8: ...ysically place the AR300 receiver on your amp or in front of you Extend its antennas vertically and spread the tips horizontally outwards 3 Set the power switch on your AG300 transmitter to the off po...

Страница 9: ...al performance level while observing the AF Meter If the AF Meter reads above 0 indicating a Peak condition even with the AR300 Level control fully counterclockwise engage the 15 dB pad on the transmi...

Страница 10: ...can be adjusted using the supplied plastic screwdriver it should normally be left at its factory setting See the Setting Up and Using the AirLine Synth System section on page 15 in this manual for mo...

Страница 11: ...Meter 10 segment bar meter used to display the level of the radio frequency reception 10 LCD Display The 47mm x 17mm backlit display show information for Frequency Channel Group Absolute Channel Annt...

Страница 12: ...r to line level equipment The output connection can be either balanced or unbalanced Wiring is as follows tip hot ring cold sleeve ground D XLR output Use this electronically balanced low impedance 60...

Страница 13: ...battery is a good operating level The LED lights steadily red when there are less than 2 hours of battery power remaining indicating that the battery needs to be changed In order to avoid compromising...

Страница 14: ...d will void your warranty 9 15 dB Pad Located under the battery is a miniature slide switch to adjust the AG300 s input sensitivity Move this switch in the direction of the arrow to reduce the output...

Страница 15: ...is also to ON Pull back gently on the AG300 battery cover at the ribbing and pry it upwards to remove it Please use care when opening this cover as undue force can damage it Install a fresh AA alkalin...

Страница 16: ...e output level of your electric guitar or bass to maximum and begin playing it at a normal performance level while observing the AR300 AF Meter If all the bars are lit indicating a Peak condition even...

Страница 17: ...l range available 14 When first setting up your AirLine Synth system in a new environment it s always a good idea to do a walkaround in order to make sure that coverage is provided for your entire per...

Страница 18: ...ion the AG300 will also display the Absolute Channel number briefly when the power is shut off 1 Press the EDIT control once and you will see the Group and Group Channel Number Flash 2 Turn the EDIT c...

Страница 19: ...mation over infrared transmission 5 Now position the transmitter about 6 inches from the front of the AR300 with the AG300 IR receiver facing the AR300 s LCD display and turn the power on You will now...

Страница 20: ...lter Output 1 4 inch and XLR Balanced LCD Display 47mm x 17mm Back Lighted Display Frequency Channel Group Absolute Channel Anntena AF RF Scan IR Set Controls EDIT Encoder Button Volume Squelch Operat...

Страница 21: ...LED Interface Infrared Impedance 2 2k ohms Battery AA x 1 Current Consumption Less than 120mA Operating Voltage 1 2V 1 5V Battery Life 10 hours 25 C Operating Temperature 0 C 50 C RF Output Power 10m...

Страница 22: ...1 this device may not cause harmful interference and 2 this device must accept any interference received includ ing interference that may cause Undesired operation AirLine Synth UHF Wireless Micropho...

Страница 23: ......

Страница 24: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Отзывы: