![Samson 2357-11 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/samson/2357-11/2357-11_mounting-and-operating-instructions_3762791005.webp)
EB 2560 EN
5
Process medium and scope of application
2
Process medium and scope of application
Pressure regulators for cryogenic gases and liquids as well as other liquids, gases and va-
pors. Operating pressures up to 63 bar, with set points from 1 to 40 bar. Temperature range
from –200 to +200 °C. Oxygen clean according to international standards and guidelines.
The regulators are designed to keep the pressure constant to the adjusted set point, especial-
ly in cryogenic plants.
WARNING!
Risk of injury and property damage due to high pressure in the plant!
A suitable overpressure protection must be installed on site in the plant section.
2.1
Transportation and storage
The regulators must be carefully handled, transported and stored. Protect the regulators
against adverse influences, such as dust, dirt or moisture before they are installed.
In the delivered state, the pressure regulators are packed to be free of oil and grease for oxy-
gen service. To avoid contamination, do not open the packaging until immediately before in-
stallation.
Содержание 2357-11
Страница 15: ...EB 2560 EN 15...