Fluid Solenoids are installed at each dispense point (Station). Use the instruction sheet included
with the Fluid Solenoid for correct installation. For reels, mount the Fluid Solenoid next to the reel
and connect the side hose to the fluid outlet of the Solenoid, for Oil Bars mount the Fluid
Solenoid above arms reach on the wall (to prevent intentional short circuiting by the end user
and possible system damage).
Ì
CAUTION:
There are two different versions of the Fluid Solenoid, Model 1065 is for Oils (0-
3000PSI) and Model 1064 is for water base products - Windshield Wash Fluid and Anti Freeze (0-
250PSI).
Samson Corporation-Swannanoa, NC 28778-
800.311.1047 www.samsoncorporation.com
Troubleshooting
Input Voltage/Amperage
Voltaje/Amperaje De Entrada
120 VAC/10AMPS (minimum)
Input Fuse
Fusible De la Entrada
2.25 Amps
Output Voltage
Voltaje De la Salida
24VAC
Output Amps
Salida Amperios
2.25 Amps (fused)
Transformer Rating
Grado Del Transformador
40VA
Maximum Stations Controlled Estaciones Máximas Controladas
10
Maximum Pre-Set Quantity
El Máximo Preestableció Cantidad 99999.9 Units
Minimum Pre-Set Quantity
El Mínimo Preestableció Cantidad .1 Units
Maximum Totalizer Value
Valor Máximo Del Totalizador
9999999.9 Units (Rolls over to Zero
– not externally resettable)
Maximum Fluid Pressure (Oil) Presión de fluido máxima (Aceite) 180 bar (3000 PSI)
Maximum Fluid Pressure (H20) Presión de fluido máxima (H20)
15 bar (250 PSI)
Minimum Flow
Flujo Mínimo
1 l/min (¼GPM)
Maximum Flow
Flujo Máximo
26 l/min (6 GPM)
Symptoms Possible
Reasons
Solutions
120VAC Power input cord unplugged.
Plug the Power Cord into a properly
grounded outlet.
Main Circuit Breaker Tripped at building
Panel.
Unplug the DFC console and find the
cause of the fault and rectify before
resetting Circuit Breaker.
External Fuse on back of DFC Blown.
Find the cause of the fault and rectify
before replacing the fuse.
Dispense
not
Authorized.
Authorize a dispense using the
Operation section of this manual.
No Power.
DFC Ready Light OFF.
Station Ready Light OFF.
No Product flow at any Dispense Point.
DFC Defective.
Replace DFC.
Station Selector in wrong position.
Rotate the switch to the correct Station.
Output Fuse Blown.
Find the cause of the fault and rectify
before replacing the fuse.
Station wires connected incorrectly.
Trace wire routing and connections and
repair.
Station wires defective, shorted or
grounded internally and/or externally.
Trace and Repair.
Station wires defective, broken
internally or disconnected.
Trace and Repair.
Ready Light defective.
Test for continuity and Repair.
DFC Ready Light ON.
Ready Light at Station OFF.
No Product flow at Dispense Point.
Ready Light and Fluid Solenoid wired in
Series Circuit.
Rewire in Parallel Circuit.
1060
5
Technical Data/ Datos Técnicos