background image

PM

Professional equipment

elektronik

Sams elektronik d.o.o. • [email protected] • www.sams.rs

8

FUSE:  500mA

AC  ~230V/50Hz

VIDEO INPUT

VIDEO OUTPUT

RS-232

AUDIO INPUT

AUDIO OUTPUT

1

R

EF

3

2 4

5 7

6 8

1 3

2 4

5 7

6 8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

POWER

CH 1

CH 2

CH 1

CH 2

USE ONLY  WITH A 250V FUSE

8x8 composite video  / stereo unbalanced audio routing switcher

PM-88va2

LCD

www.sams.rs

VIDEO

SOURCE

1

2

3

4

5

6

7

8

AUDIO CH1 AUDIO CH2

VIDEO SOURCE

LOCK

AUDIO 

CH1

 SOURCE

AUDIO 

CH2

 SOURCE

UNDO

LOCK

PAN. LOCK

DESTINATION

DESTINATION

DESTINATION

DESTINATION

DESTINATION

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

1234567812345678

        12345678

SOURCE

VIDEO

UNDO

VIDEO IN

VIDEO OUT

AUDIO IN CH 1/2

AUDIO OUT CH 1/2

POWER

SHITCH

AC 

SOCKET

RS-232

LOCK

P. LOCK

AUDIO 1

AUDIO 2

STATUS

DESTINATION

ROUTING SWITCHER STATUS ON LCD

CONNECTIONS TO X-Y COMMAND

On the front panel, select the type of signal you want to connect, press the button VIDEO-AUDIO1-

Audio2  ENABLE.  If  the  button  is  illuminated,  you  can  use  the  video  or  audio  source.  Video  button 

blinks until you connect an external reference. Video sources can be used without external reference 

but connection will not be synchronized. To make the connection, press the output. While holding the 

button, press the button of the desired input. In this way you connect signals.

Notice if LOCK button is ON when you press output button. Only if LOCK button is off you can use this 

output.  Buttons are numericaly defined. You can connect one input to more then one output. To check 

which input is connected to which output, just press one of input buttons and output(s) will light on. 

In the same way you can press output button to see which input is connected.  Connection status is 

displayed on the LCD.

 

LOCK

This key is used to lock the desired output. Press the desired output. You will see that there is already 

pre-selected input. If necessary, the user change the desired input by pressing as described above in 

the text. Press output and then press LOCK. If the LOCK button is illuminated, the output is locked. 

Unlocking is done in the same way. Press the locked output (LOCK button is illuminated). While holding 

the button, press the LOCK. Status of locked outputs is displayed on the LCD.

UNDO

When you press and hold the output, and if UNDO button is illuminated, pressing UNDO returns the 

connection  to  the  previous  connection  status.  This  means  that  any  reconnection  can  take  a  step 

back. Memory remembers only one step in all three levels of connection (Video - Video 1 - Video 2) 

independently, except in cases that routing switcher is reseted or turned on for the first time.

PANEL LOCK

PANEL LOCK button is used to lock the entire panel due to the use of computer. If you have the software 

to control the routing switcher via a computer, you must lock the routing switcher. If the PANEL LOCK is 

off, the software is used only for monitoring the connections.

VIDEO SOURCE

LOCK

AUDIO 

CH1

 SOURCE

AUDIO 

CH2

 SOURCE

DESTINATION

DESTINATION

DESTINATION

DESTINATION

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8

1234567812345678

        12345678

Status

Video out

Locked out

Video in

Audio CH1 out

Audio CH1 in

Audio CH2 in

Audio CH2 out

INSTALLATION

Содержание PM-88va2lcd

Страница 1: ...blished 05 june 2009 Updated 25 november 2014 Z10 3 edition 1 Code 007 102 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage ...

Страница 2: ...facturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of se...

Страница 3: ...of high voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device SAFETY WARNINGS ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of ...

Страница 4: ... device is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and ...

Страница 5: ...ektronik d o o sams sams rs www sams rs elektronik 5 UNPACKING AND INSTALLATION 6 MAINTENANCE 6 REMOVAL AND STORAGE 6 DESCRIPTION 7 INSTALLATION 8 ROUTING SWITCHER STATUS ON LCD 8 SOFTWARE 9 NOTES 10 Page Description TABLE OF CONTENTS ...

Страница 6: ...5 The device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 Remove the protective wrap from the chassis For devices that are AC 230V 50Hz ...

Страница 7: ...X INPUT Number 8 Level 1V p p nominal video Impedance 75Ω Connectors BNC female OUTPUT Number 8 Connectors BNC Impedance 75Ω Hum on output 43dB at 5 5MHz Output level 1V p p PERFORMANCE Frequency responce 0 1dB 50Hz to 5 5MHz ORDERING INFORMATION Code Name Description 007 102 PM 88va2lcd Video 2CH audio matrix 8x8 Specifications and designs are subject to change without notice PM 88va2 a 8x8 integ...

Страница 8: ...more then one output To check which input is connected to which output just press one of input buttons and output s will light on In the same way you can press output button to see which input is connected Connection status is displayed on the LCD LOCK This key is used to lock the desired output Press the desired output You will see that there is already pre selected input If necessary the user ch...

Страница 9: ...PM Professional equipment Sams elektronik d o o sams sams rs www sams rs elektronik 9 SOFTWARE 1 2 Loading status Saving status Lock window Naming inputs outputs Double click on field ...

Страница 10: ...if you do not connect properly or if routing switcher is turned off If you want to control the routing switcher using a PC press PANEL LOCK on the front panel of the remote control Red indicator PC ENABLE will appear instead of OK COM Destinations that were previously locked will not be used Using the program is simple Place the arrow at the intersection XY and press the left mouse button The para...

Отзывы: