background image

10  |  

SAMLEX AMERICA, INC.

Section 5  

|  Limiting Electromagnetic Interference

!

  CAUTION!

Conducted and radiated noises in this unit are limited as per the applicable National / Inter-
national Standards. In North America, the applicable standard is FCC Part 15(B) for Class “B” 
Digital Devices for Residential Installations. The corresponding European standard is EN55022, 
Class “B” & EN610000-3-2, 3. 

This unit generates, uses and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference to radio communications. 
However, this does not guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the measures recommended in the following paragraphs.

UN-INTENTIONAL RF NOISE GENERATED BY SWITCHED MODE POWER 
SUPPLIES (SMPS)

Switched Mode Power Supplies (SMPS) employ high frequency switching (25 KHz in this 
unit) and thus, are a source of radio interference, a recipient of radio interference and a 
conduit of radio interference. (Older Linear Type, low frequency 50 / 60 Hz transformer 
based power supplies do not employ high frequency switching voltages and will be quieter 
as compared to SMPS).

The primary emission sources originate in the switching devices due to their fast switching 
current transitions: harmonics of the switching frequency and broadband noise created by 
under-damped oscillations in the switching circuit. The secondary source is from the bridge 
rectifier, both rectifier noise and diode recovery. The AC input rectifier / capacitor in the 
front end of the SMPS (excepting those with Power Factor correction) generate power sup-
ply harmonics due to the non-linear input current waveform. The noise is both conducted 
and radiated through the input power cord and the DC output wiring to the radio. 

FILTRATION OF CONDUCTED NOISE

The conducted RF noise from this SMPS unit is limited to the maximum allowable  
levels by internal filtration. The filtered RF noise currents (< few hundred micro Amps) are 
bypassed to the chassis of the power supply. The chassis is, in turn, connected to  
the Earth Ground pin of the AC input power cord (for Class 1 units). Thus, the filtered 
noise currents are intentionally leaked to the Earth Ground. This is termed as the “Earth 
Leakage Current”. 

EXCESSIVE RF OUTPUT INTERFERENCE BY SMPS DUE TO INCOMING  
RF INTERFERENCE WHEN POWERING RADIO TX / RX

SMPS are also recipients of radio interference. The normal operation of the power sup-
ply can be disturbed due to RF noise getting coupled into the power supply. Thus, the 
power supply may generate excessive RF noise and lose output voltage regulation due to 
excessive transmitter energy being coupled through the AC / DC lines to the power sup-
ply’s regulator feedback path. This may be due to antenna being too close or due to the 
antenna or feed system not radiating properly. First check the antenna system SWR. 

Содержание SEC-1235

Страница 1: ...SAMLEX AMERICA INC 1 Switch Mode DC Power Supplies SEC 1235 SEC 1235M Please read this manual BEFORE installing your Power Supply Owner s Manual ...

Страница 2: ...AL Index SECTION 1 Safety Instructions 3 SECTION 2 Layout Dimensions 4 SECTION 3 Product Overview 6 SECTION 4 Troubleshooting Guide 9 SECTION 5 Limiting Electromagnetic Interference 10 SECTION 6 Specifications 13 SECTION 7 Warranty 15 ...

Страница 3: ...ape as those of the original power supply plug 4 Place the unit in an area that will allow air to flow freely around the unit DO NOT BLOCK OR OBSTRUCT vent openings on the side bottom of the unit 5 Keep the unit away from moisture and water 6 NEVER operate the units in parallel WARNING Your power supply should be grounded to reduce the risk of electric shock The power supply comes with a detachabl...

Страница 4: ... 320 C13 connector on one end and NEMA5 15P plug on the other end 3 Black Negative DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 4 Red Positive DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 5 Air inlet slots for cooling fan cooling fan and air outlet slots at the bottom not shown Dimensions WxDxH 185 x 208 x 61 mm 7 28...

Страница 5: ...onnector on one end and NEMA5 15P plug on the other end 3 Black Negative DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 4 Red Positive DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 5 Air inlet slots for cooling fan cooling fan and air outlet slots at the bottom not shown 6 Voltmeter 7 Ammeter Dimensions WxDxH 185 x 212 ...

Страница 6: ...e printed circuit board PCB have been connected shorted with a flexible wire jumper To convert to 230 VAC input disconnect the quick disconnect connector at point D by pulling it upwards Tape this end with an insulation tape and use a cable tie to tie it securely to the wire harness running above The fuse on the AC side for the preset input voltage of 120 VAC is rated at 250V 8A For 230 VAC op era...

Страница 7: ... input connection AC outlet and the fuse inside the power supply The voltmeter on SEC 1235M will read 13 8V Now switch ON the DC load The ammeter on SEC 1235M will indicate the current drawn by the load Ensure that the continuous load is limited to 30A Cooling Fan Control Thermal Protection WARNING Operate the unit in a well ventilated open and cool area DO NOT block the openings at the fan discha...

Страница 8: ...nd 10 to 11 4V When a deeply discharged 12V battery is charged at say 13 8V it will initially draw a very large current As the battery capacity is restored the battery voltage increases to around 13 8V when fully charged and the current drawn by the battery reduces a few hundred mA If a deeply discharged battery is directly charged by SEC 1235 SEC 1235M the battery will initially draw a very large...

Страница 9: ...s regulation and drops to 13 5V the unit is overloaded and is in current limit The load is trying to draw the current limit value of 35A If the voltage drop is considerable with voltage 2V the load side is seeing a short circuit and short circuit current limited to the cur rent limited to 35A is being driven into the short circuit AC input voltage setting has been changed to 230 VAC but AC input v...

Страница 10: ...s due to their fast switching current transitions harmonics of the switching frequency and broadband noise created by under damped oscillations in the switching circuit The secondary source is from the bridge rectifier both rectifier noise and diode recovery The AC input rectifier capacitor in the front end of the SMPS excepting those with Power Factor correction generate power sup ply harmonics d...

Страница 11: ...ers The RF absorption of the ferrite coated cable avoids resonances at high frequencies reducing the conducted and radiated RF noises even further For example consider suitability of EMC Cord IMU 14 from EMC Eupen www emceupen com or similar Use additional appropriate DC radio frequency interference RFI power line filter rated for minimum 30 A immediately after the DC output of the power supply Fo...

Страница 12: ...mally installed in AC Branch Circuits feeding power outlets in wet areas like marine craft RVs spas hot tubs kitchens washrooms etc As explained earlier RF noise filtration circuits in SMPS generate intentional Earth Leakage Current SMPS are used extensively as DC power sources in modern day electrical elec tronic devices e g Audio Video Computing devices power supplies battery chargers etc A sing...

Страница 13: ...to recovery Output Noise and Ripple 150 mV Peak to Peak Peak Efficiency 85 5 Output Metering Voltmeter and Ammeter DESIGN Type Switch Mode Power Supply SMPS with Fixed Frequency Pulse Width Modulation PWM Output Side Switching Frequency 30 5 KHz PROTECTIONS Short Circuit Overload Constant Current Limiting at 35A Auto Reset Over Voltage Regulated by PWM Controller Over Temperature Output shuts down...

Страница 14: ...or USA UL Standard ANSI UL 60950 1 and for Canada CSA Standard CAN CSA C22 2 No 60950 1 Electro Magnetic Inter ference EMI Radiated Conducted FCC Part 15 B Class B INPUT OUTPUT CONNECTIONS AC Input Connection IEC 320 C14 Inlet Connector on the unit Detachable Power Cord with o IEC 320 C13 Connector on one end o NEMA5 15P Plug on the other end DC Output Connectors Terminal with Tubular Hole Diamete...

Страница 15: ...ing a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh water spray or wa...

Страница 16: ... Toll Free Numbers Ph 800 561 5885 Fax 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders samlexamerica com ...