SamplexPower SAM-1000-12 Скачать руководство пользователя страница 4

 

www.samlexpower.com

 

 

HOW YOUR INVERTER WORKS 

 

The inverter converts low voltage DC (Direct Current) from a battery or other power source to 
standard 115 volt AC (Alternating Current) household power. 

 

PRINCIPLE OF OPERATION 

The inverter converts power in two stages. The first stage is a DC to DC conversion process 
that raises the low voltage DC at the inverter input to 150 volts DC. The second stage is the 
actual inverter stage that converts the high voltage DC into 115 volts, 60 Hz AC(rms). The 
DC-to-DC converter stage uses modern high frequency power conversion techniques that 
have replaced the bulky transformers found in less technologically-advanced models. The 
inverter stage uses advanced power MOSFET transistors in a full bridge configuration. 

 

THE OUTPUT WAVEFORM 

The AC output waveform of the SAM Series inverter is known as “modified sine wave”. It is a 
waveform that has characteristics similar to the sine wave shape of utility power. This type of 
waveform is suitable for most AC loads, including linear and switching power supplies used in 
electronic equipment, transformers, and motors. (See Figure 1).   

The modified sine wave produced by the inverter has an RMS (root mean square) voltage of 
115 volts, which is the same as standard household power. Most AC voltmeters (both digital 
and analog) are sensitive to the average value of the waveform rather than the RMS value. 
They are calibrated for RMS voltage under the assumption that the waveform measured will be 
a pure sine wave. These meters will not read the RMS voltage of a modified sine wave 
correctly. They will read about 20 to 30 volts low when measuring the output of the inverter. For 
accurate measurement of the output voltage of this unit, use a true RMS reading voltmeter 
such as a Fluke 87III, Fluke 8060A, Fluke 77/99 series or Beckman 4410. 

 

FIGURE 1 : 

  Modified Sine Wave and Sine Wave Comparison 

 

 

 

 

 

 

 

Содержание SAM-1000-12

Страница 1: ...INS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE Featured Design Cool Surface Technology Power Save Mode Technology Soft Start Technology ...

Страница 2: ...s 12 V DC cigarette plug connections and terminal connections 4 This is not a toy keep away from children 5 DO NOT install object into air vents CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks and boats are negative ground Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter 2 This inverte...

Страница 3: ...ovides full automatic inverter and battery protection This includes overheat protection battery protection overload protection short circuit protection and earth fault protection L I T greatly improves the interference problems of common power inverter Before introduction of L I T signal interference may occur on TV pictures audio system or radio equipments Now you can enjoy a clean and powerful A...

Страница 4: ... as modified sine wave It is a waveform that has characteristics similar to the sine wave shape of utility power This type of waveform is suitable for most AC loads including linear and switching power supplies used in electronic equipment transformers and motors See Figure 1 The modified sine wave produced by the inverter has an RMS root mean square voltage of 115 volts which is the same as stand...

Страница 5: ...ill provide you 115 VAC when powered by a 12 VDC source such as is found in a vehicle or multiple battery configurations as shown in FIGURE 2 This manual does not describe all of the possible types of battery configurations battery charging configurations and battery isolation configurations To properly operate the inverter the DC power source must provide between 11 0 and 15 0 VDC and nominally a...

Страница 6: ... be mounted on a wall mount it horizontally so that indicators switches outlets and terminal blocks located on the front panel are visible and accessible If inverter is to be installed in a moving vehicle we strongly recommends that the inverter be shock mounted either on the floor in a clear safe area or on a secure flat surface CAUTION The power inverter must be connected only to batteries with ...

Страница 7: ...to the positive terminal of the inverter 5 Connect a length of wire between the inverter s negative terminal and the DC power source negative terminal 6 Connect a short length of wire to the other terminal of the fuse holder or circuit breaker Mark it POSITIVE or 7 Connect the free end of the fuse or breaker wire to the positive terminal of the DC power source battery 8 Insert a suitable fuse in t...

Страница 8: ...The inverter should only be used in locations that meet the following criteria DRY Do not allow water and or other liquids to come into contact with the power inverter In all marine applications do not install the inverter below or near the waterline and keep the inverter away from moisture or water COOL Ambient air temperature should be between 30 degrees F 1 degree C non condensing and 105 degre...

Страница 9: ...erload if necessary turn the power switch OFF then ON DETERMINING BATTERY SIZE To determine the minimum battery size that you will need to operate appliances follow these steps 1 Determine the wattage of each appliance and or tool you will need to simultaneously operate from the inverter To do this read the labels on the equipment to be operated Usually power consumption is shown in watts If it is...

Страница 10: ...he standard current leakage allowance When large current leakage to earth terminal occurs the protection circuit activated and shut down the inverter which prevent electric shock to human Turn OFF the inverter unplug the fault AC appliance and then turn ON is the only way to restart it LOW BATTERY ALARM An alarm will sound when the voltage from the battery drops to 10 6 volts This is an indication...

Страница 11: ... YES YES YES YES 3000W NO YES YES YES YES Standard USB charging port 5Vdc 500mA Compatible with SAM Series remote control only Connect with incompatible remote cable will damage the power inverter remote Turn off the inverter and allow the unit fuse to cool for at least 30 minutes before reset the fuse And reduce the output load before restart DC Terminal Plastic Covers and Nuts are for terminal p...

Страница 12: ...ncorporates a higher quality power amplified supply TELEVISION INTERFERENCE The inverter is shielded to minimize interference with TV signals The problem may not be with the inverter However in some instances some interference may still be visible particularly with weak TV signals Try the following corrective measures Position the inverter as far as possible from the television the antenna and the...

Страница 13: ...t Green LED lit Earth fault protection is activated by excessive current leakage from the load Unplug the faulted load Low battery alarm sounds abnormal Bad connection or wiring Tighten all DC connections Low battery alarm sounds Low battery voltage Recharge or replace battery Motorized power tool won t start Excessive start up load If appliance does not start then appliance is drawing excessive w...

Страница 14: ...igh voltage and high temperature inside CAUTION NO USER SERVICEABLE COMPONENTS INSIDE DO NOT ATTEMPT TO OPEN THE INVERTER SPECIFICATIONS Output Connection North America AC Receptacle s Output Voltage Approx 115 volt AC RMS 60 Hz Output Waveform Soft Start Modified Sine Wave Max Efficiency Approximately 90 Input Voltage 12 5 volt DC Input Fuse Internal Samlex America Inc 110 17 Fawcett Road Coquitl...

Отзывы: