background image

 

www.samlexpower.com

 

 

2. OPERATION STEPS 

1.  Make sure environment is cool and dry. 

2.  Plug the unit into the vehicle’s accessory outlets. 

3.  Rotate the plug slightly to ensure good and firmly connection. 

4.  Green LED light on indicates a proper operation. 

5.  Plug in the AC appliance. 

The vehicle’s accessory outlets must provide between 11 and 15 volts DC and must be able to 
supply the necessary current to operate the load. To obtain a rough estimate of the current (in 
amperes) the power source must deliver; simply divide the power consumption of the load (in 
watts AC) by 10. 

Example: lf a load is rated at 80 watts AC, the power source must be able to deliver: 80 divided 
by 10=8 amperes 

Testing is the only definitive way to determine whether a specific load can be started and how 
long it can run. The unit will shut down if it is overloaded.   

CAUTION:

 Check the maximum supply current of your vehicle’s 12V outlet by referring to your 

vehicle’s owner manual. 

CAUTION:

  The  unit  must  be  connected  only  to  batteries  with  a  nominal  output  voltage  of  12 

volts.  The  unit  will  not  operate  from  a  6  volt  battery,  and  will  sustain  permanent  damage  if 
connected to a 24 volt battery. 

CAUTION:

  Do  not  use  with  positive  ground  electrical  systems.  (The  majority  of  modern 

automobiles, RVs, and trucks are negative ground). 

 

3. PROTECTIVE FEATURES 

OVER TEMPERATURE PROTECTION

 – If the temperature inside the unit is too high, the unit 

will automatically shut down. Allow the unit to cool for at least 30 minutes before restarting after a 
heat-related shutdown. Unplug unit while cooling. 

LOW  BATTERY  VOLTAGE  PROTECTION

  -  The  unit  automatically  shuts  down  when  input 

voltage drops to around 10.0 volts. When the condition is corrected, the unit may be restarted. 

OVER VOLTAGE PROTECTION

 – The unit will automatically shut down when the input voltage 

exceeds 15.5 volts DC.   

 

Содержание SAM-100-12

Страница 1: ...DC AC Power Inverter SAM 100 12 Please read this manual before installing your inverter Owner s Manual ...

Страница 2: ...he neutral will cause the unit to shut down Do not operate this unit if it is wet 4 This product is not tested for use with medical devices 5 Loose connectors may cause overheated junction and melted insulation 6 Unplug the unit when it is idle The unit should only be used in locations that meet the following criteria DRY Do not allow water and or other liquids to come into contact with the unit C...

Страница 3: ...t transformers and motors See Figure 1 The modified sine wave has an RMS root mean square voltage of 115 volts which is the same as standard household power Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave These meters w...

Страница 4: ...n if it is overloaded CAUTION Check the maximum supply current of your vehicle s 12V outlet by referring to your vehicle s owner manual CAUTION The unit must be connected only to batteries with a nominal output voltage of 12 volts The unit will not operate from a 6 volt battery and will sustain permanent damage if connected to a 24 volt battery CAUTION Do not use with positive ground electrical sy...

Страница 5: ...overloaded and the green LED is not lit the internal fuse may be blown 1 Unscrew the flange of the unit counterclockwise 2 Remove the end contact flange and fuse 3 Inspect the fuse to see if it is good or blown 4 Replace with a new fuse of same type same dimension and same ampere rating 5 Carefully reassemble the fuse end contact and flange CAUTION NO USER SERVICEABLE COMPONENTS INSIDE DO NOT ATTE...

Страница 6: ...er of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh water spray or water immersion No othe...

Страница 7: ...0 561 5885 Fax 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders samlexamerica com 11002 SAM 100 12 0612 ...

Отзывы: